The DOI matches its Crossref record; 20 of the 20 references it cites were found in a registry or an index.
Statistical variation of aberration structure and image quality in a normal population of healthy eyes
Abstract
A Shack-Hartmann aberrometer was used to measure the monochromatic aberration structure along the primary line of sight of 200 cyclopleged, normal, healthy eyes from 100 individuals. Sphero-cylindrical refractive errors were corrected with ophthalmic spectacle lenses based on the results of a subjective refraction performed immediately prior to experimentation. Zernike expansions of the experimental wave-front aberration functions were used to determine aberration coefficients for a series of pupil diameters. The residual Zernike coefficients for defocus were not zero but varied systematically with pupil diameter and with the Zernike coefficient for spherical aberration in a way that maximizes visual acuity. We infer from these results that subjective best focus occurs when the area of the central, aberration-free region of the pupil is maximized. We found that the population averages of Zernike coefficients were nearly zero for all of the higher-order modes except spherical aberration. This result indicates that a hypothetical average eye representing the central tendency of the population is nearly free of aberrations, suggesting the possible influence of an emmetropization process or evolutionary pressure. However, for any individual eye the aberration coefficients were rarely zero for any Zernike mode. To first approximation, wave-front error fell exponentially with Zernike order and increased linearly with pupil area. On average, the total wave-front variance produced by higher-order aberrations was less than the wave-front variance of residual defocus and astigmatism. For example, the average amount of higher-order aberrations present for a 7.5-mm pupil was equivalent to the wave-front error produced by less than 1/4 diopter (D) of defocus. The largest pupil for which an eye may be considered diffraction-limited was 1.22 mm on average. Correlation of aberrations from the left and right eyes indicated the presence of significant bilateral symmetry. No evidence was found of a universal anatomical feature responsible for third-order optical aberrations. Using the Marechal criterion, we conclude that correction of the 12 largest principal components, or 14 largest Zernike modes, would be required to achieve diffraction-limited performance on average for a 6-mm pupil. Different methods of computing population averages provided upper and lower limits to the mean optical transfer function and mean point-spread function for our population of eyes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Thibos, L. N., WHEELER, W., & Horner, D. G. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04707.x · Cited by 1,238
Self-citationLiang, J., Grimm, B., Goelz, S., & Bille, J. F. (1994) · Journal of the Optical Society of America A · doi:10.1364/josaa.11.001949 · Cited by 1,195
Standards for Reporting the Optical Aberrations of Eyes
Thibos, L. N., Applegate, R. A., Schwiegerling, J. T., Webb, R., & Members, V. S. T. (2000) · Vision Science and its Applications · doi:10.1364/vsia.2000.suc1 · Cited by 824
Self-citationAberrations and retinal image quality of the normal human eye
Liang, J., & Williams, D. R. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.002873 · Cited by 764
Monochromatic aberrations of the human eye in a large population
Porter, J., Guirao, A., Cox, I. G., & Williams, D. R. (2001) · Journal of the Optical Society of America A · doi:10.1364/josaa.18.001793 · Cited by 711
The Depth of Field of the Human Eye
Campbell, F. W. (1957) · Optica Acta International Journal of Optics · doi:10.1080/713826091 · Cited by 386
A subjective method for the measurement of monochromatic* aberrations of the eye
Howland, H. C., & Howland, B. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.001508 · Cited by 379
The chromatic eye: a new reduced-eye model of ocular chromatic aberration in humans
Thibos, L. N., Ye, M., Zhang, X., & Bradley, A. (1992) · Applied Optics · doi:10.1364/ao.31.003594 · Cited by 309
Self-citationAge-related changes in monochromatic wave aberrations of the human eye.
McLellan, J. S., Marcos, S. C., & Burns, S. A. (2001) · PubMed · Cited by 293
Average optical performance of the human eye as a function of age in a normal population.
Guirao, A., González, C., Redondo, M., Geraghty, E., Norrby, S., & Artal, P. (1999) · PubMed · Cited by 274
A Demonstration of the Visual Importance and Flexibility of Spatial-Frequency Amplitude and Phase
Piotrowski, L. N., & Campbell, F. W. (1982) · Perception · doi:10.1068/p110337 · Cited by 247
Objective technique for the determination of monochromatic aberrations of the human eye
Walsh, G., Howland, H. C., & Charman, W. N. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000987 · Cited by 220
Applegate, R. A., & Lakshminarayanan, V. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001611 · Cited by 201
THE DEPTH-OF-FOCUS OF THE HUMAN EYE FOR SNELLEN LETTERS
Tucker, J., & Charman, W. N. (1975) · Optometry and Vision Science · doi:10.1097/00006324-197501000-00002 · Cited by 160
Subjective Depth-of-Focus of the Eye
Atchison, D. A., Charman, W. N., & Woods, R. L. (1997) · Optometry and Vision Science · doi:10.1002/j.1538-9235.1997.tb04744.x · Cited by 158
The longitudinal chromatic aberration of the human eye, and its correction
Howarth, P. A., & Bradley, A. (1986) · Vision Research · doi:10.1016/0042-6989(86)90034-9 · Cited by 148
Self-citationRynders, M. C., Lidkea, B., Chisholm, W., & Thibos, L. N. (1995) · Journal of the Optical Society of America A · doi:10.1364/josaa.12.002348 · Cited by 121
Self-citationKoomen, M. J., Scolnik, R., & Tousey, R. (1951) · Journal of the Optical Society of America · doi:10.1364/josa.41.000080 · Cited by 99
The refraction of the eye in the relation to spherical aberration and pupil size.
Charman, W. N., Jennings, J. A. M., & Whitefoot, H. (1978) · PubMed · Cited by 77
Estimates of the ocular wave aberration from pairs of double-pass retinal images
Iglesias, I. C., Berrio, E., & Artal, P. (1998) · Journal of the Optical Society of America A · doi:10.1364/josaa.15.002466 · Cited by 68
Cited by
Vergence–accommodation conflicts hinder visual performance and cause visual fatigue
Hoffman, D. M., Girshick, A. R., Akeley, K., & Banks, M. S. (2008) · Journal of Vision · doi:10.1167/8.3.33 · Cited by 1,625
Accuracy and precision of objective refraction from wavefront aberrations
Thibos, L. N., Hong, X., Bradley, A., & Applegate, R. A. (2004) · Journal of Vision · doi:10.1167/4.4.9 · Cited by 570
Self-citationInteraction between aberrations to improve or reduce visual performance
Applegate, R. A., Marsack, J. D., Ramos, R., & Sarver, E. J. (2003) · Journal of Cataract and Refractive Surgery · doi:10.1016/s0886-3350(03)00334-1 · Cited by 403
A unified formula for light-adapted pupil size
Watson, A. B., & Yellott, J. I. (2012) · Journal of Vision · doi:10.1167/12.10.12 · Cited by 399
Recent developments in optical coherence tomography for imaging the retina
van Velthoven, M. E. J., Faber, D. J., Verbraak, F. D., van Leeuwen, T. G., & de Smet, M. D. (2007) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2006.10.002 · Cited by 343
Metadata
- Authors
- Thibos, L. N., Hong, X., Bradley, A., & Cheng, X.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 2002-12-01
- Volume
- 19
- Issue
- 12
- Pages
- 2329
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2004597357
- Cited by
- 622
- References
- 20
- FWCI
- 12.76
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.