The DOI matches its Crossref record.
Multilayer model of photon diffusion in skin
Abstract
A diffusion model describing the propagation of photon flux in the epidermal, dermal, and subcutaneous tissue layers of the skin is presented. Assuming that the skin is illuminated by a collimated, finite-aperture source, we develop expressions relating photon flux density within the skin and intensities re-emitted from the skin surface to the optical properties of the individual layers. Model simulations show that the rate at which re-emitted intensities diminish with radial distance away from the source can provide information about absorption and scattering in underlying tissues. Re-emitted intensities measured from homogeneous and two-layer tissue phantoms compare favorably with model predictions. We demonstrate potential applications of the model by estimating the absorption (sigma a) and transport-corrected scattering (sigma's) coefficients of dermis and subcutis from intensities measured from intact skin and by predicting the magnitude of the optical-density variations measured by a photoplethysmograph.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Double-integrating-sphere system for measuring the optical properties of tissue
Pickering, J. W., Prahl, S. A., van Wieringen, N., Beek, J. F., Sterenborg, H. J. C. M., & van Gemert, M. J. C. (1993) · Applied Optics · doi:10.1364/ao.32.000399 · Cited by 461
A review of in‐vivo optical properties of human tissues and its impact on PDT
Sandell, J. L., & Zhu, T. C. (2011) · Journal of Biophotonics · doi:10.1002/jbio.201100062 · Cited by 384
Noninvasive determination of the optical properties of two-layered turbid media
Kienle, A., Patterson, M. S., Dögnitz, N., Bays, R., Wagnières, G., & van den Bergh, H. (1998) · Applied Optics · doi:10.1364/ao.37.000779 · Cited by 294
Analysis of human faces using a measurement-based skin reflectance model
Weyrich, T., Matusik, W., Pfister, H., Bickel, B., Donner, C., Tu, C., McAndless, J., Lee, J., Ngan, A., Jensen, H. W., et al. (2006) · ACM Transactions on Graphics · doi:10.1145/1141911.1141987 · Cited by 291
In Vivo Near-Infrared Spectroscopy
Rolfe, P. (2000) · Annual Review of Biomedical Engineering · doi:10.1146/annurev.bioeng.2.1.715 · Cited by 273
Franceschini, M. A., Fantini, S., Paunescu, L. A., Maier, J. S., & Gratton, E. (1998) · Applied Optics · doi:10.1364/ao.37.007447 · Cited by 172
Phan, T., Rowland, R. A., Ponticorvo, A., Le, B. C., Sharif, S. A., Kennedy, G. T., Wilson, R. H., & Durkin, A. J. (2022) · Journal of Biomedical Optics · doi:10.1117/1.jbo.27.3.036002 · Cited by 18
“used a layered diffusion model to simulate optical properties from a single point for a given source–detector separation.(24) They used reference values for μa and μs 0 from previous reports to model the epidermis, dermis, and subcutaneous layers at 660 and 950 nm.”
Method
Metadata
- Authors
- Schmitt, J. M., Wall, R. T., Zhou, G. X., & Walker, E. C.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1990-11-01
- Volume
- 7
- Issue
- 11
- Pages
- 2141
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2020659724
- Cited by
- 204
- References
- 0
- FWCI
- 6.85
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.