Color appearance in the peripheral retina: effects of stimulus size
The DOI matches its Crossref record; 29 of the 29 references it cites were found in a registry or an index.
Abstract
Hue and saturation scaling were used to measure the appearance of spectral lights as a function of stimulus size for nine loci across the horizontal retinal meridian. At a given locus, each hue (R, Y, G, and B) grew as a function of stimulus size up to some asymptotic value. The parameter values of Michaelis-Menten growth functions fitted to the hue data were used to derive the sizes of the so-called perceptive fields of the hue mechanisms. The fields for all mechanisms increased with eccentricity, and this increase was greater on the temporal than on the nasal retina. By increasing stimulus size it was possible to achieve fovealike color vision to eccentricities of 20 deg. However, even the largest stimuli failed to produce fully saturated hues at 40 deg. The retinal size scales of the four hue mechanisms were not the same; those for R and B were similar, and these mechanisms had the smallest perceptive fields everywhere. The perceptive fields of the hue mechanisms at all loci were larger than anatomical estimates of the sizes of retinal receptive fields.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Psychophysical evidence for separate channels for the perception of form, color, movement, and depth
Livingstone, M., & Hubel, D. (1987) · The Journal of Neuroscience · doi:10.1523/jneurosci.07-11-03416.1987 · Cited by 1,758
The contrast sensitivity of human colour vision to red‐green and blue‐yellow chromatic gratings.
Mullen, K. T. (1985) · The Journal of Physiology · doi:10.1113/jphysiol.1985.sp015591 · Cited by 964
An estimation and application of the human cortical magnification factor
Rovamo, J., & Virsu, V. (1979) · Experimental Brain Research · doi:10.1007/bf00236819 · Cited by 790
Retinal ganglion cells that project to the dorsal lateral geniculate nucleus in the macaque monkey
Perry, V. H., Oehler, R., & Cowey, A. (1984) · Neuroscience · doi:10.1016/0306-4522(84)90006-x · Cited by 717
Visual properties of neurons in area V4 of the macaque: sensitivity to stimulus form
Desimone, R., & Schein, S. J. (1987) · Journal of Neurophysiology · doi:10.1152/jn.1987.57.3.835 · Cited by 680
Functional properties of ganglion cells of the rhesus monkey retina.
De Monasterio, F. M., & Gouras, P. (1975) · The Journal of Physiology · doi:10.1113/jphysiol.1975.sp011086 · Cited by 616
Cat and monkey retinal ganglion cells and their visual functional roles
Shapley, R., & Hugh Perry, V. (1986) · Trends in Neurosciences · doi:10.1016/0166-2236(86)90064-0 · Cited by 588
Distribution of Cones in Human and Monkey Retina: Individual Variability and Radial Asymmetry
Curcio, C. A., Sloan, K. R., Packer, O., Hendrickson, A. E., & Kalina, R. E. (1987) · Science · doi:10.1126/science.3576186 · Cited by 585
Functional anatomy of macaque striate cortex. II. Retinotopic organization
Tootell, R., Switkes, E., Silverman, M., & Hamilton, S. (1988) · The Journal of Neuroscience · doi:10.1523/jneurosci.08-05-01531.1988 · Cited by 502
Functional anatomy of macaque striate cortex. III. Color
Tootell, R., Silverman, M., Hamilton, S., De Valois, R., & Switkes, E. (1988) · The Journal of Neuroscience · doi:10.1523/jneurosci.08-05-01569.1988 · Cited by 472
Human cortical magnification factor and its relation to visual acuity
Cowey, A., & Rolls, E. T. (1974) · Experimental Brain Research · doi:10.1007/bf00237163 · Cited by 403
Colorimetric and photometric properties of a 2° fundamental observer
Vos, J. J. (1978) · Color Research & Application · doi:10.1002/col.5080030309 · Cited by 379
Visual Sensitivity and Parallel Retinocortical Channels
Shapley, R. (1990) · Annual Review of Psychology · doi:10.1146/annurev.ps.41.020190.003223 · Cited by 321
Spatial interaction in human cone vision
Westheimer, G. (1967) · The Journal of Physiology · doi:10.1113/jphysiol.1967.sp008198 · Cited by 317
Chromatic Organization of Primate Cones
Marc, R. E., & Sperling, H. G. (1977) · Science · doi:10.1126/science.403607 · Cited by 256
Punctate sensitivity of the blue-sensitive mechanism
Williams, D. R., MacLeod, D. I. A., & Hayhoe, M. M. (1981) · Vision Research · doi:10.1016/0042-6989(81)90242-x · Cited by 204
Visual resolution and contour interaction in the fovea and periphery
Jacobs, R. J. (1979) · Vision Research · doi:10.1016/0042-6989(79)90183-4 · Cited by 193
Color vision in the peripheral retina II Hue and saturation*
Gordon, J., & Abramov, I. (1977) · Journal of the Optical Society of America · doi:10.1364/josa.67.000202 · Cited by 178
Self-citationColour Sensitivity of the Fovea Centralis
Willmer, E. N., & Wright, W. D. (1945) · Nature · doi:10.1038/156119a0 · Cited by 165
Hue-Wavelength Relation Measured by Color-Naming Method for Three Retinal Locations
Boynton, R. M., Schafer, W., & Neun, M. E. (1964) · Science · doi:10.1126/science.146.3644.666 · Cited by 147
Sensitivity to spatiotemporal colour contrast in the peripheral visual field
Noorlander, C., Koenderink, J. J., Olden, R. J. D., & Edens, B. W. (1983) · Vision Research · doi:10.1016/0042-6989(83)90035-4 · Cited by 146
Simultaneous masking interactions between chromatic and luminance gratings
Valois, K. K. D., & Switkes, E. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.000011 · Cited by 138
Spectral sensitivity and wave‐length discrimination of the peripheral retina
Weale, R. A. (1953) · The Journal of Physiology · doi:10.1113/jphysiol.1953.sp004837 · Cited by 135
Blue-Blindness in the Normal Fovea*
Wald, G. (1967) · Journal of the Optical Society of America · doi:10.1364/josa.57.001289 · Cited by 126
Color naming of small foveal fields
Ingling, C. R., Scneibner, H. M. O., & Boynton, R. M. (1970) · Vision Research · doi:10.1016/0042-6989(70)90006-4 · Cited by 77
Spectral sensitivity and wavelength discrimination of the human peripheral visual field
van Esch, J. A., Koldenhof, E. E., van Doorn, A. J., & Koenderink, J. J. (1984) · Journal of the Optical Society of America A · doi:10.1364/josaa.1.000443 · Cited by 73
Color Vision in the Peripheral Retina
Johnson, M. A. (1986) · Optometry and Vision Science · doi:10.1097/00006324-198602000-00003 · Cited by 73
Scaling procedures for specifying color appearance
Gordon, J., & Abramov, I. (1988) · Color Research & Application · doi:10.1002/col.5080130307 · Cited by 69
Self-citationPerception of colour in unilateral tritanopia.
Alpern, M., Kitahara, K., & Krantz, D. H. (1983) · The Journal of Physiology · doi:10.1113/jphysiol.1983.sp014558 · Cited by 58
Cited by
De Valois, R. L., & De Valois, K. K. (1993) · Vision Research · doi:10.1016/0042-6989(93)90240-w · Cited by 541
Capabilities and Limitations of Peripheral Vision
Rosenholtz, R. (2016) · Annual Review of Vision Science · doi:10.1146/annurev-vision-082114-035733 · Cited by 378
Organization of the human trichromatic cone mosaic
Hofer, H., Carroll, J., Neitz, J., Neitz, M., & Williams, D. R. (2005) · The Journal of Neuroscience · doi:10.1523/jneurosci.2414-05.2005 · Cited by 364
Color perception in the intermediate periphery of the visual field
Hansen, T., Pracejus, L., & Gegenfurtner, K. R. (2009) · Journal of Vision · doi:10.1167/9.4.26 · Cited by 251
“The decrease in color performance is likely a result of the spatial organization of the retina and not just a loss in sensitivity (Abramov et al., 1991; Martin, Lee, White, Solomon, & Rüttiger, 2001).”
BackgroundSpatial density and immunoreactivity of bipolar cells in the macaque monkey retina
Martin, P. R., & Grünert, U. (1992) · Journal of Comparative Neurology · doi:10.1002/cne.903230210 · Cited by 168
Metadata
- Authors
- Abramov, I., Gordon, J., & Chan, H.
- Venue
- Journal of the Optical Society of America A
- Publisher
- Optica Publishing Group
- Published
- 1991-02-01
- Volume
- 8
- Issue
- 2
- Pages
- 404
- ISSN
- 1084-7529 (ISSN-L)
- 1520-8532
- OpenAlex
- W2073985290
- Cited by
- 167
- References
- 29
- FWCI
- 2.72
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.