The DOI matches its Crossref record; 14 of the 14 references it cites were found in a registry or an index.
High-stability transfer of an optical frequency over long fiber-optic links
Abstract
We present theoretical predictions and experimental measurements for the achievable phase noise, timing jitter, and frequency stability in the coherent transport of an optical frequency over a fiber-optic link. Both technical and fundamental limitations to the coherent transfer are discussed. Measurements of the coherent transfer of an optical carrier over links ranging from 38 to 251 km demonstrate good agreement with theory. With appropriate experimental design and bidirectional transfer on a single optical fiber, the frequency instability at short times can reach the fundamental limit imposed by delay-unsuppressed phase noise from the fiber link, yielding a frequency instability that scales as link length to the 3/2 power. For two-way transfer on separate outgoing and return fibers, the instability is severely limited by differential fiber noise.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Laser phase and frequency stabilization using an optical resonator
Drever, R. W. P., Hall, J. L., Kowalski, F. V., Hough, J., Ford, G. M., Munley, A. J., & Ward, H. (1983) · Applied Physics B Photophysics and Laser Chemistry · doi:10.1007/bf00702605 · Cited by 3,811
Ma, L.-S., Jungner, P., Ye, J., & Hall, J. L. (1994) · Optics Letters · doi:10.1364/ol.19.001777 · Cited by 566
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Coherent transfer of an optical carrier over 251 km
Newbury, N. R., Williams, P. A., & Swann, W. C. (2007) · Optics Letters · doi:10.1364/ol.32.003056 · Cited by 228
Self-citationComparison between frequency standards in Europe and the USA at the 10−15uncertainty level
Bauch, A., Achkar, J., Bize, S., Calonico, D., Dach, R., Hlavać, R., Lorini, L., Parker, T., Petit, G., Piester, D., et al. (2006) · Metrologia · doi:10.1088/0026-1394/43/1/016 · Cited by 225
Considerations on the measurement of the stability of oscillators with frequency counters
Dawkins, S. T., McFerran, J. J., & Luiten, A. N. (2007) · IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control · doi:10.1109/tuffc.2007.337 · Cited by 220
Delivery of high-stability optical and microwave frequency standards over an optical fiber network
Ye, J., Peng, J.-L., Jones, R. J., Holman, K. W., Hall, J. L., Jones, D. J., Diddams, S. A., Kitching, J., Bize, S., Bergquist, J. C., et al. (2003) · Journal of the Optical Society of America B · doi:10.1364/josab.20.001459 · Cited by 206
Long-Distance Frequency Dissemination with a Resolution of 10−17
Daussy, C., Lopez, O., Amy‐Klein, A., Goncharov, A., Guinet, M., Chardonnet, C., Narbonneau, F., Lours, M., Chambon, D., Bize, S., et al. (2005) · Physical Review Letters · doi:10.1103/physrevlett.94.203904 · Cited by 169
High resolution frequency standard dissemination via optical fiber metropolitan network
Narbonneau, F., Lours, M., Bize, S., Clairon, A., Santarelli, G., Lopez, O., Daussy, C., Amy-Klein, A., & Chardonnet, C. (2006) · Review of Scientific Instruments · doi:10.1063/1.2205155 · Cited by 166
Coherent Optical Phase Transfer over a 32-km Fiber with 1 s Instability at 10−17
Foreman, S. M., Ludlow, A. D., de Miranda, M. H. G., Stalnaker, J. E., Diddams, S. A., & Ye, J. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.153601 · Cited by 143
Long-term femtosecond timing link stabilization using a single-crystal balanced cross correlator
Kim, J., Chen, J., Zhang, Z., Wong, F. N. C., Kärtner, F. X., Loehl, F., & Schlarb, H. (2007) · Optics Letters · doi:10.1364/ol.32.001044 · Cited by 126
Coddington, I. R., Swann, W. C., Lorini, L., Bergquist, J., Coq, Y. L., Oates, C. W., Quraishi, Q. S., Feder, K. S., Nicholson, J. W., Westbrook, P. S., et al. (2007) · Nature Photonics · doi:10.1038/nphoton.2007.71 · Cited by 124
Self-citationOn the measurement of frequency and of its sample variance with high-resolution counters
Rubiola, E. (2005) · Review of Scientific Instruments · doi:10.1063/1.1898203 · Cited by 120
Musha, M., Satô, Y., Nakagawa, K., Ueda, K., Ueda, A., & Ishiguro, M. (2006) · Applied Physics B · doi:10.1007/s00340-005-2125-6 · Cited by 27
Research works printed but not linked: 3
- Williams, 1999, Electron. Lett., 35, 1578, 10.1049/el:19991068 · doi:10.1049/el:19991068
- Lee, 2001, IEEE Photon. Technol. Lett., 13, 76, 10.1109/68.903226 · doi:10.1109/68.903226
- Sheard, 2006, Appl. Phys. Lett., 45, 8491
Cited by
Ludlow, A. D., Boyd, M. M., Ye, J., Peik, E., & Schmidt, P. O. (2015) · Reviews of Modern Physics · doi:10.1103/revmodphys.87.637 · Cited by 2,385
A clock network for geodesy and fundamental science
Lisdat, C., Grosche, G., Quintin, N., Shi, C., Raupach, S. M. F., Grebing, C., Nicolodi, D., Stefani, F., Al-Masoudi, A., Dörscher, S., et al. (2016) · Nature Communications · doi:10.1038/ncomms12443 · Cited by 460
Ultrastable laser interferometry for earthquake detection with terrestrial and submarine cables
Marra, G., Clivati, C., Luckett, R., Tampellini, A., Kronjäger, J., Wright, L., Mura, A., Levi, F., Robinson, S., Xuereb, A., et al. (2018) · Science · doi:10.1126/science.aat4458 · Cited by 407
Optical-Frequency Transfer over a Single-Span 1840 km Fiber Link
Droste, S., Ozimek, F., Udem, T., Predehl, K., Hänsch, T. W., Schnatz, H., Grosche, G., & Holzwarth, R. (2013) · Physical Review Letters · doi:10.1103/physrevlett.111.110801 · Cited by 315
Riehle, F. (2017) · Nature Photonics · doi:10.1038/nphoton.2016.235 · Cited by 264
Metadata
- Authors
- Williams, P. A., Swann, W. C., & Newbury, N. R.
- Venue
- Journal of the Optical Society of America B
- Publisher
- Optica Publishing Group
- Published
- 2008-07-17
- Volume
- 25
- Issue
- 8
- Pages
- 1284
- ISSN
- 0740-3224 (ISSN-L)
- 1520-8540
- OpenAlex
- W2159646889
- Cited by
- 385
- References
- 14
- FWCI
- 9.09
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.org/10.1364/OA_License_v1#VOR (vor)
- opg.optica.org/policies/opg-tdm-policy.json (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.