The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Fluorescence emission at dielectric and metal-film interfaces
Abstract
It is well known that the classical optical properties of a bare or metal-film-coated dielectric surface significantly the emission pattern of a fluorophore in close proximity to it. Most previous classical calculations of this perturb model the fluorophore as a continuous fixed-amplitude dipole acting as a simple radiator. However, for effect modeling steady-state excitation, a fixed-power dipole is more appropriate. This modification corresponds to normalizing fixed-amplitude dipole intensities by the total dissipated power, which is itself dependent on fluorophore orientation and proximity to the surface. The results for the fixed-power model differ nontrivially from the fixed-amplitude model. Using the fixed-power dipole model, we calculate the observation-angle-dependent intensity as a function of the fluorophore’s orientation and distance from the surface. The surface can have an intermediate layer of arbitrary thickness on it, which is used to model a metal-film-coated dielectric. In addition, general expressions are derived for the emission power as observed through a circular-aperture collection system (such as a microscope objective) located on either side of the interface. These expressions are applied to several common cases of fluorophore spatial and orientational distributions at bare glass–water and metal-film-coated glass-water interfaces. The results suggest practical experimental approaches for measuring the spatial and orientational distribution of fluorophores adsorbed at a surface, utilizing the distance-dependent fluorescence near a metalized surface and optimizing the collection efficiency from a well-defined volume near a quenching surface.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Constants of the Noble Metals
Johnson, P. B., & Christy, R. W. (1972) · Physical Review B · doi:10.1103/physrevb.6.4370 · Cited by 20,094
Cited by
Single Molecules Observed by Near-Field Scanning Optical Microscopy
Betzig, E., & Chichester, R. J. (1993) · Science · doi:10.1126/science.262.5138.1422 · Cited by 1,262
Total Internal Reflection Fluorescence Microscopy in Cell Biology
Axelrod, D. (2001) · Traffic · doi:10.1034/j.1600-0854.2001.21104.x · Cited by 959
Self-citationMethods of single-molecule fluorescence spectroscopy and microscopy
Moerner, W. E., & Fromm, D. P. (2003) · Review of Scientific Instruments · doi:10.1063/1.1589587 · Cited by 881
Single-molecule orientations determined by direct emission pattern imaging
Lieb, M. A., Zavislan, J. M., & Novotny, L. (2004) · Journal of the Optical Society of America B · doi:10.1364/josab.21.001210 · Cited by 425
Imaging and Time-Resolved Spectroscopy of Single Molecules at an Interface
Macklin, J. J., Trautman, J. K., Harris, T. D., & Brus, L. E. (1996) · Science · doi:10.1126/science.272.5259.255 · Cited by 422
Metadata
- Authors
- Hellen, E. H., & Axelrod, D.
- Venue
- Journal of the Optical Society of America B
- Publisher
- Optica Publishing Group
- Published
- 1987-03-01
- Volume
- 4
- Issue
- 3
- Pages
- 337
- ISSN
- 0740-3224 (ISSN-L)
- 1520-8540
- OpenAlex
- W1981170205
- Cited by
- 241
- References
- 1
- FWCI
- 4.66
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Fluorescence emission at dielectric and metal-film interfaces. https://app.cochat.ai/papers/10.1364/josab.4.000337
- The paper
- Hellen, E. H., & Axelrod, D. (1987). Fluorescence emission at dielectric and metal-film interfaces. Journal of the Optical Society of America B. https://doi.org/10.1364/josab.4.000337
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.