The DOI matches its Crossref record.
Molecular specific optoacoustic imaging with plasmonic nanoparticles
Open accessAbstract
Gold nanoparticles functionalized with antibodies can specifically bind to molecular biomarkers such as epithelial growth factor receptor (EGFR). The molecule specific nature of the antibody-functionalized gold nanoparticles forms the basis for the developed optoacoustic imaging technique to detect cancer at an asymptotic stage. Optoacoustic imaging was performed with 532 nm and 680 nm pulsed laser irradiation on three-dimensional tissue phantoms prepared using a human keratinocyte cell line. The results of our study demonstrate that the combination of anti-EGFR gold ioconjugates and optoacoustic imaging can allow highly sensitive and selective detection of human epithelial cancer cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Wang, B., Yantsen, E., Larson, T., Karpiouk, A. B., Sethuraman, S., Su, J. L., Sokolov, K., & Emelianov, S. Y. (2009) · Nano Letters · doi:10.1021/nl801852e · Cited by 208
Self-citationIndocyanine Green J Aggregates in Polymersomes for Near-Infrared Photoacoustic Imaging
Changalvaie, B., Han, S., Moaseri, E., Scaletti, F., Truong, L., Caplan, R., Cao, A., Bouchard, R., Truskett, T. M., Sokolov, K. V., et al. (2019) · ACS Applied Materials & Interfaces · doi:10.1021/acsami.9b14519 · Cited by 93
Self-citation
Metadata
- Authors
- Mallidi, S., Larson, T., Aaron, J., Sokolov, K., & Emelianov, S.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2007
- Volume
- 15
- Issue
- 11
- Pages
- 6583
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2014077561
- Cited by
- 186
- References
- 0
- FWCI
- 13.26
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecular specific optoacoustic imaging with plasmonic nanoparticles. https://app.cochat.ai/papers/10.1364/oe.15.006583
- The paper
- Mallidi, S., Larson, T., Aaron, J., Sokolov, K., & Emelianov, S. (2007). Molecular specific optoacoustic imaging with plasmonic nanoparticles. Optics Express. https://doi.org/10.1364/oe.15.006583
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.