Effect of optical correction and remaining aberrations on peripheral resolution acuity in the human eye
Open accessThe DOI matches its Crossref record.
Abstract
Retinal sampling poses a fundamental limit to resolution acuity in the periphery. However, reduced image quality from optical aberrations may also influence peripheral resolution. In this study, we investigate the impact of different degrees of optical correction on acuity in the periphery. We used an adaptive optics system to measure and modify the off-axis aberrations of the right eye of six normal subjects at 20 degrees eccentricity. The system consists of a Hartmann-Shack sensor, a deformable mirror, and a channel for visual testing. Four different optical corrections were tested, ranging from foveal sphero-cylindrical correction to full correction of eccentric low- and high-order monochromatic aberrations. High-contrast visual acuity was measured in green light using a forced choice procedure with Landolt C's, viewed via the deformable mirror through a 4.8-mm artificial pupil. The Zernike terms mainly induced by eccentricity were defocus and with- and against-the-rule astigmatism and each correction condition was successfully implemented. On average, resolution decimal visual acuity improved from 0.057 to 0.061 as the total root-mean-square wavefront error changed from 1.01 mum to 0.05 mum. However, this small tendency of improvement in visual acuity with correction was not significant. The results suggest that for our experimental conditions and subjects, the resolution acuity in the periphery cannot be improved with optical correction.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical quality of emmetropic and myopic eyes in the periphery measured with high-angular resolution
Jaeken, B., & Artal, P. (2012) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.11-8993 · Cited by 75
Self-citationWave-aberration control with a liquid crystal on silicon (LCOS) spatial phase modulator
Fernández, E. J., Prieto, P. M., & Artal, P. (2009) · Optics Express · doi:10.1364/oe.17.011013 · Cited by 57
Self-citationVisual performance with lenses correcting peripheral refractive errors
Atchison, D. A., Mathur, A., & Varnas, S. R. (2013) · Optometry and Vision Science · doi:10.1097/opx.0000000000000033 · Cited by 29
“Lundström et al.9 found negligible improvement in visual acuity at 20- eccentricity in the nasal visual field despite increasing the degree of peripheral correction in stages from on-axis (foveal) spherocylindrical correction to full correction of peripheral second- and higher-order monochromatic aberrations.”
BackgroundOh, S.-K., Kim, J.-M., Yoon, G.-Y., Yoo, Y.-S., & Kim, D. Y. (2024) · Photonics · doi:10.3390/photonics11040332 · Cited by 1
Metadata
- Authors
- Lundström, L., Manzanera, S., Prieto, P. M., Ayala, D. B., Gorceix, N., Gustafsson, J., Unsbo, P., & Artal, P.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2007
- Volume
- 15
- Issue
- 20
- Pages
- 12654
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2157256130
- Cited by
- 82
- References
- 0
- FWCI
- 3.46
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Effect of optical correction and remaining aberrations on peripheral resolution acuity in the human eye. https://app.cochat.ai/papers/10.1364/oe.15.012654
- The paper
- Lundström, L., Manzanera, S., Prieto, P. M., Ayala, D. B., Gorceix, N., Gustafsson, J., Unsbo, P., & Artal, P. (2007). Effect of optical correction and remaining aberrations on peripheral resolution acuity in the human eye. Optics Express. https://doi.org/10.1364/oe.15.012654
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.