Active Fourier-transform spectroscopy combining the direct RF beating of two fiber-based mode-locked lasers with a novel referencing method
Open accessThe DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Abstract
A new approach is described to compensate the variations induced by laser frequency instabilities in the recently demonstrated Fourier transform spectroscopy that is based on the RF beating spectra of two frequency combs generated by mode-locked lasers. The proposed method extracts the mutual fluctuations of the lasers by monitoring the beating signal for two known optical frequencies. From this information, a phase correction and a new time grid are determined that allow the full correction of the measured interferograms. A complete mathematical description of the new active spectroscopy method is provided. An implementation with fiberbased mode-locked lasers is also demonstrated and combined with the correction method a resolution of 0.067 cm(-1) (2 GHz) is reported. The ability to use slightly varying and inexpensive frequency comb sources is a significant improvement compared to previous systems that were limited to controlled environment and showed reduced spectral resolution. The fast measurement rate inherent to the RF beating principle and the ease of use brought by the correction method opens the venue to many applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
“Indeed, to date the majority of DCS demonstrations have been performed in the ∼1550 nm telecommunication band, where there are relatively inexpensive and robust erbium fiber frequency combs, fiber-optic components, and high-bandwidth, sensitive photoreceivers [9,10,17,19,24,25,29,34,36,42,44,50,53].”
Fermann, M. E., & Hartl, I. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.280 · Cited by 1,160
Rapid and precise absolute distance measurements at long range
Coddington, I., Swann, W. C., Nenadovic, L., & Newbury, N. R. (2009) · Nature Photonics · doi:10.1038/nphoton.2009.94 · Cited by 1,059
Microresonator soliton dual-comb spectroscopy
Suh, M.-G., Yang, Q.-F., Yang, K. Y., Yi, X., & Vahala, K. J. (2016) · Science · doi:10.1126/science.aah6516 · Cited by 991
Cavity-enhanced dual-comb spectroscopy
Bernhardt, B., Ozawa, A., Jacquet, P., Jacquey, M., Kobayashi, Y., Udem, T., Holzwarth, R., Guelachvili, G., Hänsch, T. W., & Picqué, N. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.217 · Cited by 594
Metadata
- Authors
- Giaccari, P., Deschênes, J.-D., Saucier, P., Genest, J., & Tremblay, P.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-03-14
- Volume
- 16
- Issue
- 6
- Pages
- 4347
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2019530504
- Cited by
- 129
- References
- 2
- FWCI
- 5.99
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Active Fourier-transform spectroscopy combining the direct RF beating of two fiber-based mode-locked lasers with a novel referencing method. https://app.cochat.ai/papers/10.1364/oe.16.004347
- The paper
- Giaccari, P., Deschênes, J.-D., Saucier, P., Genest, J., & Tremblay, P. (2008). Active Fourier-transform spectroscopy combining the direct RF beating of two fiber-based mode-locked lasers with a novel referencing method. Optics Express. https://doi.org/10.1364/oe.16.004347
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.