Biomedical sensors, integrated into textiles would enable monitoring of many vitally important physiological parameters during our daily life. In this paper we demonstrate the design and performance of a textile based pulse oximeter, operating on the forefinger tip in transmission mode. The sensors consisted of plastic optical fibers integrated into common fabrics. To emit light to the human tissue and to collect transmitted light the fibers were either integrated into a textile substrate by embroidery (producing microbends with a nominal diameter of 0.5 to 2 mm) or the fibers inside woven patterns have been altered mechanically after fabric production. In our experiments we used a two-wavelength approach (690 and 830 nm) for pulse wave acquisition and arterial oxygen saturation calculation. We have fabricated different specimens to study signal yield and quality, and a cotton glove, equipped with textile based light emitter and detector, has been used to examine movement artifacts. Our results show that textile-based oximetry is feasible with sufficient data quality and its potential as a wearable health monitoring device is promising.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Principles, Techniques, and Limitations of Near Infrared Spectroscopy
Ferrari, M., Mottola, L., & Quaresima, V. (2004) · Canadian Journal of Applied Physiology · doi:10.1139/h04-031 · Cited by 997
Monitoring tissue oxygen availability with near infrared spectroscopy (NIRS) in health and disease
Boushel, R., Langberg, H., Olesen, J., Gonzales‐Alonzo, J., Bülow, J., & Kjær, M. (2001) · Scandinavian Journal of Medicine & Science in Sports · doi:10.1034/j.1600-0838.2001.110404.x · Cited by 469
Cited by
Scholkmann, F., Kleiser, S., Metz, A. J., Zimmermann, R., Mata Pavia, J., Wolf, U., & Wolf, M. (2014) · NeuroImage · doi:10.1016/j.neuroimage.2013.05.004 · Cited by 2,002
Self-citationMonitoring of Vital Signs with Flexible and Wearable Medical Devices
Khan, Y., Ostfeld, A. E., Lochner, C. M., Pierre, A., & Arias, A. C. (2016) · Advanced Materials · doi:10.1002/adma.201504366 · Cited by 1,408
Imani, S., Bandodkar, A. J., Mohan, A. M. V., Kumar, R., Yu, S., Wang, J., & Mercier, P. P. (2016) · Nature Communications · doi:10.1038/ncomms11650 · Cited by 861
Unobtrusive Sensing and Wearable Devices for Health Informatics
Zheng, Y.-L., Ding, X.-R., Poon, C. C. Y., Lo, B. P. L., Zhang, H., Zhou, X.-L., Yang, G.-Z., Zhao, N., & Zhang, Y.-T. (2014) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2014.2309951 · Cited by 722
Wearable Electrochemical Sensors and Biosensors: A Review
Windmiller, J. R., & Wang, J. (2013) · Electroanalysis · doi:10.1002/elan.201200349 · Cited by 696
Metadata
- Authors
- Rothmaier, M., Selm, B., Spichtig, S., Haensse, D., & Wolf, M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-08-11
- Volume
- 16
- Issue
- 17
- Pages
- 12973
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2080119082
- Cited by
- 111
- References
- 2
- FWCI
- 2.13
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Photonic textiles for pulse oximetry. https://app.cochat.ai/papers/10.1364/oe.16.012973
- The paper
- Rothmaier, M., Selm, B., Spichtig, S., Haensse, D., & Wolf, M. (2008). Photonic textiles for pulse oximetry. Optics Express. https://doi.org/10.1364/oe.16.012973
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.