The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Optically sectioned imaging by oblique plane microscopy
Open accessAbstract
This paper describes a new optically sectioning microscopy technique based on oblique selective plane illumination combined with oblique imaging. This method differs from previous selective plane illumination techniques as the same high numerical aperture lens is used to both illuminate and image the specimen. Initial results obtained using fluorescent pollen grains are presented, together with a measurement of the resolution of the system and an analysis of the potential performance of future systems. Since only the plane of the specimen that is being imaged is illuminated, this technique is particularly suited to time-lapse 3-D imaging of sensitive biological systems where photobleaching and phototoxicity must be kept to a minimum, and it could also be applied to image microfluidic technology for lab-on-a-chip, cytometry and other applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical Sectioning Deep Inside Live Embryos by Selective Plane Illumination Microscopy
Huisken, J., Swoger, J., Del Bene, F., Wittbrodt, J., & Stelzer, E. H. K. (2004) · Science · doi:10.1126/science.1100035 · Cited by 2,355
Highly inclined thin illumination enables clear single-molecule imaging in cells
Tokunaga, M., Imamoto, N., & Sakata-Sogawa, K. (2008) · Nature Methods · doi:10.1038/nmeth1171 · Cited by 1,305
Ultramicroscopy: three-dimensional visualization of neuronal networks in the whole mouse brain
Dodt, H.-U., Leischner, U., Schierloh, A., Jährling, N., Mauch, C. P., Deininger, K., Deussing, J. M., Eder, M., Zieglgänsberger, W., & Becker, K. (2007) · Nature Methods · doi:10.1038/nmeth1036 · Cited by 1,238
Method of obtaining optical sectioning by using structured light in a conventional microscope
Neil, M. A. A., Juškaitis, R., & Wilson, T. (1997) · Optics Letters · doi:10.1364/ol.22.001905 · Cited by 1,143
VOIE, A. H., BURNS, D. H., & SPELMAN, F. A. (1993) · Journal of Microscopy · doi:10.1111/j.1365-2818.1993.tb03346.x · Cited by 477
High-resolution three-dimensional imaging of large specimens with light sheet–based microscopy
Verveer, P. J., Swoger, J., Pampaloni, F., Greger, K., Marcello, M., & Stelzer, E. H. K. (2007) · Nature Methods · doi:10.1038/nmeth1017 · Cited by 361
Holekamp, T. F., Turaga, D., & Holy, T. E. (2008) · Neuron · doi:10.1016/j.neuron.2008.01.011 · Cited by 336
An optical technique for remote focusing in microscopy
Botcherby, E. J., Juskaitis, R., Booth, M. J., & Wilson, T. (2007) · Optics Communications · doi:10.1016/j.optcom.2007.10.007 · Cited by 254
Konopka, C. A., & Bednarek, S. Y. (2008) · The Plant Journal · doi:10.1111/j.1365-313x.2007.03306.x · Cited by 237
Cited by
A guide to light-sheet fluorescence microscopy for multiscale imaging
Power, R. M., & Huisken, J. (2017) · Nature Methods · doi:10.1038/nmeth.4224 · Cited by 636
Selective plane illumination microscopy techniques in developmental biology
Huisken, J., & Stainier, D. Y. R. (2009) · Development · doi:10.1242/dev.022426 · Cited by 608
Bouchard, M. B., Voleti, V., Mendes, C. S., Lacefield, C., Grueber, W. B., Mann, R. S., Bruno, R. M., & Hillman, E. M. C. (2015) · Nature Photonics · doi:10.1038/nphoton.2014.323 · Cited by 566
Light Sheet Fluorescence Microscopy: A Review
Santi, P. A. (2011) · Journal of Histochemistry & Cytochemistry · doi:10.1369/0022155410394857 · Cited by 431
Rapid 3D light-sheet microscopy with a tunable lens
Fahrbach, F. O., Voigt, F. F., Schmid, B., Helmchen, F., & Huisken, J. (2013) · Optics Express · doi:10.1364/oe.21.021010 · Cited by 347
Metadata
- Authors
- Dunsby, C.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2008-11-24
- Volume
- 16
- Issue
- 25
- Pages
- 20306
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2057132085
- Cited by
- 348
- References
- 9
- FWCI
- 2.42
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.