The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
Super-resolution and reconstruction of sparse sub-wavelength images
Open accessAbstract
We show that, in contrast to popular belief, sub-wavelength information can be recovered from the far-field of an optical image, thereby overcoming the loss of information embedded in decaying evanescent waves. The only requirement is that the image is known to be sparse, a specific but very general and wide-spread property of signals which occur almost everywhere in nature. The reconstruction method relies on newly-developed compressed sensing techniques, which we adapt to optical super-resolution and sub-wavelength imaging. Our approach exhibits robustness to noise and imperfections. We provide an experimental proof-of-principle by demonstrating image recovery at a spatial resolution 5-times higher than the finest resolution defined by a spatial filter. The technique is general, and can be extended beyond optical microscopy, for example, to atomic force microscopes, scanning-tunneling microscopes, and other imaging systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Negative Refraction Makes a Perfect Lens
Pendry, J. B. (2000) · Physical Review Letters · doi:10.1103/physrevlett.85.3966 · Cited by 12,159
An Introduction To Compressive Sampling
Candes, E. J., & Wakin, M. B. (2008) · IEEE Signal Processing Magazine · doi:10.1109/msp.2007.914731 · Cited by 10,017
Cited by
Structured Compressed Sensing: From Theory to Applications
Duarte, M. F., & Eldar, Y. C. (2011) · IEEE Transactions on Signal Processing · doi:10.1109/tsp.2011.2161982 · Cited by 1,128
Self-citationA super-oscillatory lens optical microscope for subwavelength imaging
Rogers, E. T. F., Lindberg, J., Roy, T., Savo, S., Chad, J. E., Dennis, M. R., & Zheludev, N. I. (2012) · Nature Materials · doi:10.1038/nmat3280 · Cited by 680
Hyperlenses and metalenses for far-field super-resolution imaging
Lu, D., & Liu, Z. (2012) · Nature Communications · doi:10.1038/ncomms2176 · Cited by 598
Compressive fluorescence microscopy for biological and hyperspectral imaging
Studer, V., Bobin, J., Chahid, M., Mousavi, H. S., Candes, E., & Dahan, M. (2012) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1119511109 · Cited by 411
Sparse deconvolution improves the resolution of live-cell super-resolution fluorescence microscopy
Zhao, W., Zhao, S., Li, L., Huang, X., Xing, S., Zhang, Y., Qiu, G., Han, Z., Shang, Y., Sun, D.-E., et al. (2022) · Nature Biotechnology · doi:10.1038/s41587-021-01092-2 · Cited by 408
Metadata
- Authors
- Gazit, S., Szameit, A., Eldar, Y. C., & Segev, M.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2009-12-16
- Volume
- 17
- Issue
- 26
- Pages
- 23920
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2021942939
- Cited by
- 168
- References
- 2
- FWCI
- 10.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.