Frequency-wavelet domain deconvolution for terahertz reflection imaging and spectroscopy
Open accessThe DOI matches its Crossref record.
Abstract
In terahertz reflection imaging, a deconvolution process is often employed to extract the impulse function of the sample of interest. A band-pass filter such as a double Gaussian filter is typically incorporated into the inverse filtering to suppress the noise, but this can result in over-smoothing due to the loss of useful information. In this paper, with a view to improving the calculation of terahertz impulse response functions for systems with a low signal to noise ratio, we propose a hybrid Frequency-Wavelet Domain Deconvolution (FWDD) for terahertz reflection imaging. Our approach works well; it retrieves more accurate impulse response functions than existing approaches and these impulse functions can then also be used to better extract the terahertz spectroscopic properties of the sample.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Smolyanskaya, O. A., Chernomyrdin, N. V., Konovko, A. A., Zaytsev, K. I., Ozheredov, I. A., Cherkasova, O. P., Nazarov, M. M., Guillet, J.-P., Kozlov, S. A., Kistenev, Y. V., et al. (2018) · Progress in Quantum Electronics · doi:10.1016/j.pquantelec.2018.10.001 · Cited by 292
Dong, J., Wu, X., Locquet, A., & Citrin, D. S. (2017) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2017.2673542 · Cited by 103
Dong, J., Locquet, A., Melis, M., & Citrin, D. S. (2017) · Scientific Reports · doi:10.1038/s41598-017-15069-2 · Cited by 82
Khani, M. E., Winebrenner, D. P., & Arbab, M. H. (2020) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2020.2997595 · Cited by 31
Khani, M. E., & Arbab, M. H. (2021) · IEEE Access · doi:10.1109/access.2021.3059424 · Cited by 29
“Especially when choosing the wavelet shrinkage thresholds from a specific interval at each decomposition level [41], these misalignments can lead to selecting erroneous threshold values.”
BackgroundMethodInfluentialKhani, M. E., & Arbab, M. H. (2022) · Sensors · doi:10.3390/s22062305 · Cited by 22
“Moreover, wavelet shrinkage accompanied by a Fourier-domain Wiener deconvolution has been proven to be effective in finding the thickness of optically-thin layers in biological samples [33] and art paintings [34].”
BackgroundSkorobogatiy, M., Sadasivan, J., & Guerboukha, H. (2018) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2018.2814820 · Cited by 11
Metadata
- Authors
- Chen, Y., Huang, S., & Pickwell-MacPherson, E.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-01-08
- Volume
- 18
- Issue
- 2
- Pages
- 1177
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2068456395
- Cited by
- 139
- References
- 0
- FWCI
- 4.49
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.