Mid-infrared Fourier transform spectroscopy with a broadband frequency comb
Open accessAbstract
We present a first implementation of optical-frequency-comb-based rapid trace gas detection in the molecular fingerprint region in the mid-infrared. Near-real-time acquisition of broadband absorption spectra with 0.0056 cm(-1) maximum resolution is demonstrated using a frequency comb Fourier transform spectrometer which operates in the 2100-to-3700-cm(-1) spectral region. We achieve part-per-billion detection limits in 30 seconds of integration time for several important molecules including methane, ethane, isoprene, and nitrous oxide. Our system enables precise concentration measurements even in gas mixtures that exhibit continuous absorption bands, and it allows detection of molecules at levels below the noise floor via simultaneous analysis of multiple spectral features.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
An Algorithm for Least-Squares Estimation of Nonlinear Parameters
Marquardt, D. W. (1963) · Journal of the Society for Industrial and Applied Mathematics · doi:10.1137/0111030 · Cited by 30,728
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Nitrous Oxide (N 2 O): The Dominant Ozone-Depleting Substance Emitted in the 21st Century
Ravishankara, A. R., Daniel, J. S., & Portmann, R. W. (2009) · Science · doi:10.1126/science.1176985 · Cited by 4,581
Acceleration of global warming due to carbon-cycle feedbacks in a coupled climate model
Cox, P. M., Betts, R. A., Jones, C. D., Spall, S. A., & Totterdell, I. J. (2000) · Nature · doi:10.1038/35041539 · Cited by 4,112
The HITRAN 2008 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Barbe, A., Benner, D. C., Bernath, P. F., Birk, M., Boudon, V., Brown, L. R., Campargue, A., Champion, J.-P., et al. (2009) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2009.02.013 · Cited by 3,335
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Diagnostic potential of breath analysis—focus on volatile organic compounds
Miekisch, W., Schubert, J. K., & Noeldge-Schomburg, G. F. E. (2004) · Clinica Chimica Acta · doi:10.1016/j.cccn.2004.04.023 · Cited by 1,096
Gas-Phase Databases for Quantitative Infrared Spectroscopy
Sharpe, S. W., Johnson, T. J., Sams, R. L., Chu, P. M., Rhoderick, G. C., & Johnson, P. A. (2004) · Applied Spectroscopy · doi:10.1366/0003702042641281 · Cited by 948
Doppler-Free Laser Polarization Spectroscopy
Wieman, C., & Hänsch, T. W. (1976) · Physical Review Letters · doi:10.1103/physrevlett.36.1170 · Cited by 870
Coherent Multiheterodyne Spectroscopy Using Stabilized Optical Frequency Combs
Coddington, I., Swann, W., & Newbury, N. (2008) · Physical Review Letters · doi:10.1103/physrevlett.100.013902 · Cited by 821
Molecular fingerprinting with the resolved modes of a femtosecond laser frequency comb
Diddams, S. A., Hollberg, L., & Mbele, V. (2007) · Nature · doi:10.1038/nature05524 · Cited by 805
Cavity-enhanced dual-comb spectroscopy
Bernhardt, B., Ozawa, A., Jacquet, P., Jacquey, M., Kobayashi, Y., Udem, T., Holzwarth, R., Guelachvili, G., Hänsch, T. W., & Picqué, N. (2010) · Nature Photonics · doi:10.1038/nphoton.2009.217 · Cited by 594
Broadband Cavity Ringdown Spectroscopy for Sensitive and Rapid Molecular Detection
Thorpe, M. J., Moll, K. D., Jones, R. J., Safdi, B., & Ye, J. (2006) · Science · doi:10.1126/science.1123921 · Cited by 511
Self-citationSpectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Frequency-comb infrared spectrometer for rapid, remote chemical sensing
Schliesser, A., Brehm, M., Keilmann, F., & van der Weide, D. W. (2005) · Optics Express · doi:10.1364/opex.13.009029 · Cited by 384
Origins and estimates of uncertainty in predictions of twenty-first century temperature rise
Stott, P. A., & Kettleborough, J. A. (2002) · Nature · doi:10.1038/416723a · Cited by 373
Current status of clinical breath analysis
Risby, T. H., & Solga, S. F. (2006) · Applied Physics B · doi:10.1007/s00340-006-2280-4 · Cited by 363
Houghton, J. (2005) · Reports on Progress in Physics · doi:10.1088/0034-4885/68/6/r02 · Cited by 361
Importance of methane and nitrous oxide for Europe's terrestrial greenhouse-gas balance
the CarboEurope Team, Schulze, E. D., Luyssaert, S., Ciais, P., Freibauer, A., Janssens, I. A., Soussana, J. F., Smith, P., Grace, J., Levin, I., et al. (2009) · Nature Geoscience · doi:10.1038/ngeo686 · Cited by 356
Fourier transform spectroscopy with a laser frequency comb
Mandon, J., Guelachvili, G., & Picqué, N. (2009) · Nature Photonics · doi:10.1038/nphoton.2008.293 · Cited by 350
Increased CO2 uncouples growth from isoprene emission in an agriforest ecosystem
Rosenstiel, T. N., Potosnak, M. J., Griffin, K. L., Fall, R., & Monson, R. K. (2003) · Nature · doi:10.1038/nature01312 · Cited by 329
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322
Phase-stabilized, 15 W frequency comb at 28–48 μm
Adler, F., Cossel, K. C., Thorpe, M. J., Hartl, I., Fermann, M. E., & Ye, J. (2009) · Optics Letters · doi:10.1364/ol.34.001330 · Cited by 314
Self-citationA multispectrum nonlinear least squares fitting technique
Benner, D. C., Rinsland, C. P., Devi, V. M., Smith, M. A. H., & Atkins, D. (1995) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/0022-4073(95)00015-d · Cited by 280
Recent advances of laser-spectroscopy-based techniques for applications in breath analysis
McCurdy, M. R., Bakhirkin, Y., Wysocki, G., Lewicki, R., & Tittel, F. K. (2007) · Journal of Breath Research · doi:10.1088/1752-7155/1/1/014001 · Cited by 237
Cavity-Enhanced Direct Frequency Comb Spectroscopy: Technology and Applications
Adler, F., Thorpe, M. J., Cossel, K. C., & Ye, J. (2010) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-060908-155248 · Cited by 236
Self-citationCurrent Status of Methods and Techniques for Breath Analysis
Cao, W., & Duan, Y. (2007) · Critical Reviews in Analytical Chemistry · doi:10.1080/10408340600976499 · Cited by 191
Gohle, C., Stein, B., Schliesser, A., Udem, T., & Hänsch, T. W. (2007) · Physical Review Letters · doi:10.1103/physrevlett.99.263902 · Cited by 188
Cavity-enhanced direct frequency comb spectroscopy
Thorpe, M. J., & Ye, J. (2008) · Applied Physics B · doi:10.1007/s00340-008-3019-1 · Cited by 167
Self-citationDetection of a Human Influence on North American Climate
Karoly, D. J., Braganza, K., Stott, P. A., Arblaster, J. M., Meehl, G. A., Broccoli, A. J., & Dixon, K. W. (2003) · Science · doi:10.1126/science.1089159 · Cited by 144
Sorokin, E., Sorokina, I. T., Mandon, J., Guelachvili, G., & Picqué, N. (2007) · Optics Express · doi:10.1364/oe.15.016540 · Cited by 132
Kornaszewski, Ł. W., Gayraud, N., Stone, J. M., MacPherson, W. N., George, A. K., Knight, J. C., Hand, D. P., & Reid, D. T. (2007) · Optics Express · doi:10.1364/oe.15.011219 · Cited by 98
Tillman, K. A., Maier, R. R. J., Reid, D. T., & McNaghten, E. D. (2004) · Applied Physics Letters · doi:10.1063/1.1808239 · Cited by 38
Current Status of Clinical Breath Analysis
Risby, T. H. (2006) · doi:10.1364/lacsea.2006.tud1 · Cited by 20
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
“Mid-IR combs can also be generated directly by OPOs at high power and with broad tuning ranges [28,33,35,41,48,68,72, 112,113].”
Hodgkinson, J., & Tatam, R. P. (2013) · Measurement Science and Technology · doi:10.1088/0957-0233/24/1/012004 · Cited by 1,745
Schliesser, A., Picqué, N., & Hänsch, T. W. (2012) · Nature Photonics · doi:10.1038/nphoton.2012.142 · Cited by 1,436
Ultralow-noise mode-locked fiber lasers and frequency combs: principles, status, and applications
Kim, J., & Song, Y. (2016) · Advances in Optics and Photonics · doi:10.1364/aop.8.000465 · Cited by 567
Advances in Mid-Infrared Spectroscopy for Chemical Analysis
Haas, J., & Mizaikoff, B. (2016) · Annual Review of Analytical Chemistry · doi:10.1146/annurev-anchem-071015-041507 · Cited by 385
Metadata
- Authors
- Adler, F., Masłowski, P., Foltynowicz, A., Cossel, K. C., Briles, T. C., Hartl, I., & Ye, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2010-09-29
- Volume
- 18
- Issue
- 21
- Pages
- 21861
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2053845346
- Cited by
- 274
- References
- 34
- FWCI
- 8.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.