The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Cavity-enhanced direct frequency comb spectroscopy
Open accessAbstract
Cavity-enhanced direct frequency comb spectroscopy combines broad spectral bandwidth, high spectral resolution, precise frequency calibration, and ultrahigh detection sensitivity, all in one experimental platform based on an optical frequency comb interacting with a high-finesse optical cavity. Precise control of the optical frequency comb allows highly efficient, coherent coupling of individual comb components with corresponding resonant modes of the high-finesse cavity. The long cavity lifetime dramatically enhances the effective interaction between the light field and intracavity matter, increasing the sensitivity for measurement of optical losses by a factor that is on the order of the cavity finesse. The use of low-dispersion mirrors permits almost the entire spectral bandwidth of the frequency comb to be employed for detection, covering a range of ∼ 10% of the actual optical frequency. The light transmitted from the cavity is spectrally resolved to provide a multitude of detection channels with spectral resolutions ranging from several gigahertz to hundreds of kilohertz. In this review we will discuss the principle of cavity-enhanced direct frequency comb spectroscopy and the various implementations of such systems. In particular, we discuss several types of UV, optical, and IR frequency comb sources and optical cavity designs that can be used for specific spectroscopic applications. We present several cavity-comb coupling methods to take advantage of the broad spectral bandwidth and narrow spectral components of a frequency comb. Finally, we present a series of experimental measurements on trace gas detections, human breath analysis, and characterization of cold molecular beams. These results demonstrate clearly that the wide bandwidth and ultrasensitive nature of the femtosecond enhancement cavity enables powerful real-time detection and identification of many molecular species in a massively parallel fashion.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Plasma perspective on strong field multiphoton ionization
Corkum, P. B. (1993) · Physical Review Letters · doi:10.1103/physrevlett.71.1994 · Cited by 7,217
Fourier Transform Infrared Spectrometry
Griffiths, P. R., & de Haseth, J. A. (2007) · doi:10.1002/047010631x · Cited by 3,052
Jones, D. J., Diddams, S. A., Ranka, J. K., Stentz, A., Windeler, R. S., Hall, J. L., & Cundiff, S. T. (2000) · Science · doi:10.1126/science.288.5466.635 · Cited by 2,661
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Spectrometry with frequency combs
Schiller, S. (2002) · Optics Letters · doi:10.1364/ol.27.000766 · Cited by 445
Remote transfer of ultrastable frequency references via fiber networks
Foreman, S. M., Holman, K. W., Hudson, D. D., Jones, D. J., & Ye, J. (2007) · Review of Scientific Instruments · doi:10.1063/1.2437069 · Cited by 403
Self-citationOptical Frequency Synthesis and Comparison with Uncertainty at the 10 -19 Level
Ma, L.-S., Bi, Z., Bartels, A., Robertsson, L., Zucco, M., Windeler, R. S., Wilpers, G., Oates, C., Hollberg, L., & Diddams, S. A. (2004) · Science · doi:10.1126/science.1095092 · Cited by 319
Cited by
Fermann, M. E., & Hartl, I. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.280 · Cited by 1,160
Coherent dual-comb spectroscopy at high signal-to-noise ratio
Coddington, I., Swann, W., & Newbury, N. (2010) · Physical Review A · doi:10.1103/physreva.82.043817 · Cited by 322
Phase-stabilized, 15 W frequency comb at 28–48 μm
Adler, F., Cossel, K. C., Thorpe, M. J., Hartl, I., Fermann, M. E., & Ye, J. (2009) · Optics Letters · doi:10.1364/ol.34.001330 · Cited by 314
Self-citationUltra-broadband dual-comb spectroscopy across 1.0–1.9 µm
Okubo, S., Iwakuni, K., Inaba, H., Hosaka, K., Onae, A., Sasada, H., & Hong, F.-L. (2015) · Applied Physics Express · doi:10.7567/apex.8.082402 · Cited by 173
Balling, P., Mašika, P., Křen, P., & Doležal, M. (2012) · Measurement Science and Technology · doi:10.1088/0957-0233/23/9/094001 · Cited by 66
Metadata
- Authors
- Thorpe, M. J., & Ye, J.
- Venue
- Applied Physics B
- Published
- 2008-05-08
- Volume
- 91
- Issue
- 3-4
- Pages
- 397-414
- ISSN
- 0721-7269 (ISSN-L)
- 0946-2171
- 1432-0649
- OpenAlex
- W2058996478
- Cited by
- 167
- References
- 7
- FWCI
- 5.98
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Cavity-enhanced direct frequency comb spectroscopy. https://app.cochat.ai/papers/10.1007/s00340-008-3019-1
- The paper
- Thorpe, M. J., & Ye, J. (2008). Cavity-enhanced direct frequency comb spectroscopy. Applied Physics B. https://doi.org/10.1007/s00340-008-3019-1
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.