The DOI matches its Crossref record; 19 of the 19 references it cites were found in a registry or an index.
Ex-vivo characterization of human colon cancer by Mueller polarimetric imaging
Open accessAbstract
Cancerous and healthy human colon samples have been analyzed ex-vivo using a multispectral imaging Mueller polarimeter operated in the visible (from 500 to 700 nm) in a backscattering configuration with diffuse light illumination. Three samples of Liberkühn colon adenocarcinomas have been studied: common, mucinous and treated by radiochemotherapy. For each sample, several specific zones have been chosen, based on their visual staging and polarimetric responses, which have been correlated to the histology of the corresponding cuts. The most relevant polarimetric images are those quantifying the depolarization for incident linearly polarized light. The measured depolarization depends on several factors, namely the presence or absence of tumor, its exophytic (budding) or endophytic (penetrating) nature, its thickness (its degree of ulceration) and its level of penetration in deeper layers (submucosa, muscularis externa and serosa). The cellular density, the concentration of stroma, the presence or absence of mucus and the light penetration depth, which increases with wavelength, are also relevant parameters. Our data indicate that the tissues with the lowest and highest depolarizing powers are respectively mucus-free tumoral tissue with high cellular density and healthy serosa, while healthy submucosa, muscularis externa as well as mucinous tumor probably feature intermediate values. Moreover, the specimen coming from a patient treated successfully with radiochemotherapy exhibited a uniform polarimetric response typical of healthy tissue even in the initially pathological zone. These results demonstrate that multi-spectral Mueller imaging can provide useful contrasts to quickly stage human colon cancer ex-vivo and to distinguish between different histological variants of tumor.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Three Monte Carlo programs of polarized light transport into scattering media: part I
Ramella-Roman, J. C., Prahl, S. A., & Jacques, S. L. (2005) · Optics Express · doi:10.1364/opex.13.004420 · Cited by 360
Three Monte Carlo programs of polarized light transport into scattering media: part II
Ramella-Roman, J. C., Prahl, S. A., & Jacques, S. L. (2005) · Optics Express · doi:10.1364/opex.13.010392 · Cited by 280
Propagation of polarized light in birefringent turbid media: A Monte Carlo study
Wang, X., & Wang, L. V. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483315 · Cited by 270
Yao, G., & Wang, L. V. (1999) · Optics Letters · doi:10.1364/ol.24.000537 · Cited by 232
Monte Carlo simulations of the diffuse backscattering Mueller matrix for highly scattering media
Bartel, S., & Hielscher, A. H. (2000) · Applied Optics · doi:10.1364/ao.39.001580 · Cited by 214
Antonelli, M.-R., Pierangelo, A., Novikova, T., Validire, P., Benali, A., Gayet, B., & De Martino, A. (2010) · Optics Express · doi:10.1364/oe.18.010200 · Cited by 193
Self-citationComparative study of polarized light propagation in biologic tissues
Sankaran, V., Walsh, J. T., & Maitland, D. J. (2002) · Journal of Biomedical Optics · doi:10.1117/1.1483318 · Cited by 184
Diffuse backscattering Mueller matricesof highly scattering media
Hielscher, A., Eick, A., Mourant, J., Shen, D., Freyer, J., & Bigio, I. (1997) · Optics Express · doi:10.1364/oe.1.000441 · Cited by 183
Modelling and validation of spectral reflectance for the colon
Džena Hidović-rowe, A., & Claridge, E. (2005) · Physics in Medicine and Biology · doi:10.1088/0031-9155/50/6/003 · Cited by 96
Interpreting Mueller matrix images of tissues
Smith, M. H. (2001) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.434690 · Cited by 87
Mueller matrix imaging polarimetry in dermatology
Smith, M. H., Burke, P. D., Lompado, A., et al. (2000) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.384904 · Cited by 81
Lo, Y., & Yu, T.-C. (2005) · Optics Communications · doi:10.1016/j.optcom.2005.08.061 · Cited by 79
The Microvascular Structure of the Normal Colon in Rats and Humans
Skinner, S. A., & O’Brien, P. E. (1996) · Journal of Surgical Research · doi:10.1006/jsre.1996.0151 · Cited by 55
Jaillon, F., & Saint‐Jalmes, H. (2003) · Applied Optics · doi:10.1364/ao.42.003290 · Cited by 55
Development of a Real-Time Corneal Birefringence Compensated Glucose Sensing Polarimeter
Cameron, B. D., & Anumula, H. (2006) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2006.8.156 · Cited by 47
In vivo light scattering for the detection of cancerous and precancerous lesions of the cervix
Mourant, J. R., Powers, T. M., Bocklage, T. J., Greene, H. M., Dorin, M. H., Waxman, A. G., Zsemlye, M. M., & Smith, H. O. (2009) · Applied Optics · doi:10.1364/ao.48.000d26 · Cited by 37
Polarized light camera to guide surgical excision of skin cancers
Jacques, S. L., Samatham, R. V., Isenhath, S., & Lee, K. C. L. (2008) · Proceedings of SPIE, the International Society for Optical Engineering/Proceedings of SPIE · doi:10.1117/12.761823 · Cited by 30
Experimental validation of the symmetric decomposition of Mueller matrices
Fallet, C., Pierangelo, A., Ossikovski, R., & Martino, A. D. (2010) · Optics Express · doi:10.1364/oe.18.000831 · Cited by 17
Self-citationExperimental implementation and properties of Stokes nondiagonalizable depolarizing Mueller matrices
Ossikovski, R., Fallet, C., Pierangelo, A., et al. (2009) · Optics Letters · doi:10.1364/ol.34.000974 · Cited by 12
Self-citation
Cited by
Tissue polarimetry: concepts, challenges, applications, and outlook
Ghosh, N. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3652896 · Cited by 740
Polarisation optics for biomedical and clinical applications: a review
He, C., He, H., Chang, J., Chen, B., Ma, H., & Booth, M. J. (2021) · Light: Science & Applications · doi:10.1038/s41377-021-00639-x · Cited by 604
Polarized light interaction with tissues
Tuchin, V. V. (2016) · Journal of Biomedical Optics · doi:10.1117/1.jbo.21.7.071114 · Cited by 384
Mueller polarimetric imaging for surgical and diagnostic applications: a review
Qi, J., & Elson, D. S. (2017) · Journal of Biophotonics · doi:10.1002/jbio.201600152 · Cited by 268
Polarimetric imaging of uterine cervix: a case study
Pierangelo, A., Nazac, A., Benali, A., Validire, P., Cohen, H., Novikova, T., Ibrahim, B. H., Manhas, S., Fallet, C., Antonelli, M.-R., et al. (2013) · Optics Express · doi:10.1364/oe.21.014120 · Cited by 255
Self-citation
Metadata
- Authors
- Pierangelo, A., Benali, A., Antonelli, M.-R., Novikova, T., Validire, P., Gayet, B., & De Martino, A.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2011-01-13
- Volume
- 19
- Issue
- 2
- Pages
- 1582
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1969465601
- Cited by
- 294
- References
- 19
- FWCI
- 10.21
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.