The DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Open accessAbstract
Amplitude decorrelation measurement is sensitive to transverse flow and immune to phase noise in comparison to Doppler and other phase-based approaches. However, the high axial resolution of OCT makes it very sensitive to the pulsatile bulk motion noise in the axial direction. To overcome this limitation, we developed split-spectrum amplitude-decorrelation angiography (SSADA) to improve the signal-to-noise ratio (SNR) of flow detection. The full OCT spectrum was split into several narrower bands. Inter-B-scan decorrelation was computed using the spectral bands separately and then averaged. The SSADA algorithm was tested on in vivo images of the human macula and optic nerve head. It significantly improved both SNR for flow detection and connectivity of microvascular network when compared to other amplitude-decorrelation algorithms.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationPerformance of fourier domain vs time domain optical coherence tomography
Leitgeb, R., Hitzenberger, C., & Fercher, A. (2003) · Optics Express · doi:10.1364/oe.11.000889 · Cited by 1,854
Sensitivity advantage of swept source and Fourier domain optical coherence tomography
Choma, M., Sarunic, M., Yang, C., & Izatt, J. (2003) · Optics Express · doi:10.1364/oe.11.002183 · Cited by 1,794
de Boer, J. F., Cense, B., Park, B. H., Pierce, M. C., Tearney, G. J., & Bouma, B. E. (2003) · Optics Letters · doi:10.1364/ol.28.002067 · Cited by 1,250
Measurement of intraocular distances by backscattering spectral interferometry
Fercher, A. F., Hitzenberger, C. K., Kamp, G., & El-Zaiat, S. Y. (1995) · Optics Communications · doi:10.1016/0030-4018(95)00119-s · Cited by 1,212
The mechanics of human saccadic eye movement
Robinson, D. A. (1964) · The Journal of Physiology · doi:10.1113/jphysiol.1964.sp007485 · Cited by 893
Speckle variance detection of microvasculature using swept-source optical coherence tomography
Mariampillai, A., Standish, B. A., Moriyama, E. H., Khurana, M., Munce, N. R., Leung, M. K. K., Jiang, J., Cable, A., Wilson, B. C., Vitkin, I. A., et al. (2008) · Optics Letters · doi:10.1364/ol.33.001530 · Cited by 699
Age-Related Macular Degeneration Is the Leading Cause of Blindness . . .
Bressler, N. M. (2004) · JAMA · doi:10.1001/jama.291.15.1900 · Cited by 684
Optical coherence tomography using a frequency-tunable optical source
Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997) · Optics Letters · doi:10.1364/ol.22.000340 · Cited by 666
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Anatomically accurate, finite model eye for optical modeling
Liou, H.-L., & Brennan, N. A. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.001684 · Cited by 612
White, B. R., Pierce, M. C., Nassif, N., Cense, B., Park, B. H., Tearney, G. J., Bouma, B. E., Chen, T. C., & de Boer, J. F. (2003) · Optics Express · doi:10.1364/oe.11.003490 · Cited by 457
Wang, R. K., An, L., Francis, P., & Wilson, D. J. (2010) · Optics Letters · doi:10.1364/ol.35.001467 · Cited by 355
Hein, I. A., & O'Brien, W. D. (1993) · IEEE Transactions on Ultrasonics, Ferroelectrics and Frequency Control · doi:10.1109/58.212556 · Cited by 309
Posterior Ciliary Artery Circulation in Health and Disease The Weisenfeld Lecture
Hayreh, S. S. (2004) · Investigative Opthalmology & Visual Science · doi:10.1167/iovs.03-0469 · Cited by 235
Doppler optical micro-angiography for volumetric imaging of vascular perfusion in vivo
Wang, R. K., & An, L. (2009) · Optics Express · doi:10.1364/oe.17.008926 · Cited by 220
Wang, Y., Bower, B. A., Izatt, J. A., Tan, O., & Huang, D. (2008) · Journal of Biomedical Optics · doi:10.1117/1.2998480 · Cited by 182
Self-citationGray-scale skeletonization of small vessels in magnetic resonance angiography
Yim, P. J., Choyke, P. L., & Summers, R. M. (2000) · IEEE Transactions on Medical Imaging · doi:10.1109/42.870662 · Cited by 177
Doppler variance imaging for three-dimensional retina and choroid angiography
Yu, L., & Chen, Z. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3302806 · Cited by 136
Cellular phone‐based photoplethysmographic imaging
Jonathan, E., & Leahy, M. J. (2010) · Journal of Biophotonics · doi:10.1002/jbio.201000050 · Cited by 119
Braaf, B., Vermeer, K. A., Sicam, V. A. D. P., van Zeeburg, E. J. T., van Meurs, J. C., & de Boer, J. F. (2011) · Optics Express · doi:10.1364/oe.19.020886 · Cited by 112
Hoeks, A. P. G., Arts, T. G. J., Brands, P. J., et al. (1993) · Ultrasound in Medicine & Biology · doi:10.1016/0301-5629(93)90090-b · Cited by 101
Tam, J., Tiruveedhula, P. K., & Roorda, A. (2011) · Biomedical Optics Express · doi:10.1364/boe.2.000781 · Cited by 100
Wang, Y., Fawzi, A. A., Tan, O., Gil-Flamer, J. H., & Huang, D. (2009) · Optics Express · doi:10.1364/oe.17.004061 · Cited by 91
Self-citationFlower, R. W., Peiretti, E., Magnani, M., Rossi, L., Serafini, S., Gryczynski, Z. K., & Gryczyński, I. (2008) · Investigative Ophthalmology & Visual Science · doi:10.1167/iovs.07-1504 · Cited by 64
Delayed macular choriocapillary circulation in age-related macular degeneration
Zhao, J., Frambach, D. A., Lee, P. P., Lee, M., & Lopez, P. F. (1995) · International Ophthalmology · doi:10.1007/bf00156412 · Cited by 39
Cited by
Optical coherence tomography angiography
Spaide, R. F., Fujimoto, J. G., Waheed, N. K., Sadda, S. R., & Staurenghi, G. (2018) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.11.003 · Cited by 1,779
Self-citationKashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Optical Coherence Tomography Angiography of Optic Disc Perfusion in Glaucoma
Jia, Y., Wei, E., Wang, X., Zhang, X., Morrison, J. C., Parikh, M., Lombardi, L. H., Gattey, D. M., Armour, R. L., Edmunds, B., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.021 · Cited by 740
Self-citationJia, Y., Bailey, S. T., Wilson, D. J., Tan, O., Klein, M. L., Flaxel, C. J., Potsaid, B., Liu, J. J., Lu, C. D., Kraus, M. F., et al. (2014) · Ophthalmology · doi:10.1016/j.ophtha.2014.01.034 · Cited by 729
Self-citationJia, Y., Bailey, S. T., Hwang, T. S., McClintic, S. M., Gao, S. S., Pennesi, M. E., Flaxel, C. J., Lauer, A. K., Wilson, D. J., Hornegger, J., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1500185112 · Cited by 665
Self-citation
Metadata
- Authors
- Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., & Huang, D.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2012-02-09
- Volume
- 20
- Issue
- 4
- Pages
- 4710
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W1528934530
- Cited by
- 1,841
- References
- 26
- FWCI
- 23.37
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.