Fluorescence suppression in Raman spectroscopy using a time-gated CMOS SPAD
Open accessThe DOI matches its Crossref record.
Abstract
A Raman spectrometer technique is described that aims at suppressing the fluorescence background typical of Raman spectra. The sample is excited with a high power (65W), short (300ps) laser pulse and the time position of each of the Raman scattered photons with respect to the excitation is measured with a CMOS SPAD detector and an accurate time-to-digital converter at each spectral point. It is shown by means of measurements performed on an olive oil sample that the fluorescence background can be greatly suppressed if the sample response is recorded only for photons coinciding with the laser pulse. A further correction in the residual fluorescence baseline can be achieved using the measured fluorescence tails at each of the spectral points.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Crocombe, R. A. (2018) · Applied Spectroscopy · doi:10.1177/0003702818809719 · Cited by 532
Single-photon avalanche diode imagers in biophotonics: review and outlook
Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0191-5 · Cited by 512
Raman spectroscopy: techniques and applications in the life sciences
Shipp, D. W., Sinjab, F., & Notingher, I. (2017) · Advances in Optics and Photonics · doi:10.1364/aop.9.000315 · Cited by 396
Review of Fluorescence Suppression Techniques in Raman Spectroscopy
Wei, D., Chen, S., & Liu, Q. (2015) · Applied Spectroscopy Reviews · doi:10.1080/05704928.2014.999936 · Cited by 334
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
The role of Raman spectroscopy in biopharmaceuticals from development to manufacturing
Esmonde-White, K. A., Cuellar, M., & Lewis, I. R. (2022) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-021-03727-4 · Cited by 152
“The SPAD approach has the advantage over iCCD or Kerr gate by means of simplified optics, a smaller footprint, and higher detector efficiency.”
MethodTime-gated Raman spectroscopy – a review
Kögler, M., & Heilala, B. (2020) · Measurement Science and Technology · doi:10.1088/1361-6501/abb044 · Cited by 107
Self-citationKögler, M., Itkonen, J., Viitala, T., & Casteleijn, M. G. (2020) · Scientific Reports · doi:10.1038/s41598-020-59091-3 · Cited by 29
Self-citation
Metadata
- Authors
- Kostamovaara, J., Tenhunen, J., Kögler, M., Nissinen, I., Nissinen, J., & Keränen, P.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2013-12-13
- Volume
- 21
- Issue
- 25
- Pages
- 31632
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2022438148
- Cited by
- 156
- References
- 0
- FWCI
- 3.80
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.