The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Quantitative differential phase contrast imaging in an LED array microscope
Open accessAbstract
Illumination-based differential phase contrast (DPC) is a phase imaging method that uses a pair of images with asymmetric illumination patterns. Distinct from coherent techniques, DPC relies on spatially partially coherent light, providing 2× better lateral resolution, better optical sectioning and immunity to speckle noise. In this paper, we derive the 2D weak object transfer function (WOTF) and develop a quantitative phase reconstruction method that is robust to noise. The effect of spatial coherence is studied experimentally, and multiple-angle DPC is shown to provide improved frequency coverage for more stable phase recovery. Our method uses an LED array microscope to achieve real-time (10 Hz) quantitative phase imaging with in vitro live cell samples.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Deterministic phase retrieval: a Green’s function solution
Teague, M. R. (1983) · Journal of the Optical Society of America · doi:10.1364/josa.73.001434 · Cited by 1,419
Phase contrast, a new method for the microscopic observation of transparent objects
Zernike, F. (1942) · Physica · doi:10.1016/s0031-8914(42)80035-x · Cited by 1,068
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584
Self-citationEmbedded pupil function recovery for Fourier ptychographic microscopy
Ou, X., Zheng, G., & Yang, C. (2014) · Optics Express · doi:10.1364/oe.22.004960 · Cited by 443
Mehta, S. B., & Sheppard, C. J. R. (2009) · Optics Letters · doi:10.1364/ol.34.001924 · Cited by 220
Microscopy refocusing and dark-field imaging by using a simple LED array
Zheng, G., Kolner, C., & Yang, C. (2011) · Optics Letters · doi:10.1364/ol.36.003987 · Cited by 142
Defocused transfer function for a partially coherent microscope and application to phase retrieval
Sheppard, C. J. R. (2004) · Journal of the Optical Society of America A · doi:10.1364/josaa.21.000828 · Cited by 78
Phase-gradient contrast in thick tissue with a scanning microscope
Mertz, J. C., Gąsecka, A., Daradich, A., Davison, I. G., & Côté, D. C. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.000407 · Cited by 15
Cited by
Transport of intensity equation: a tutorial
Zuo, C., Li, J., Sun, J., Fan, Y., Zhang, J., Lu, L., Zhang, R., Wang, B., Huang, L., & Chen, Q. (2020) · Optics and Lasers in Engineering · doi:10.1016/j.optlaseng.2020.106187 · Cited by 581
Concept, implementations and applications of Fourier ptychography
Zheng, G., Shen, C., Jiang, S., Song, P., & Yang, C. (2021) · Nature Reviews Physics · doi:10.1038/s42254-021-00280-y · Cited by 416
Quantitative Phase Imaging: Recent Advances and Expanding Potential in Biomedicine
Nguyen, T. L., Pradeep, S., Judson-Torres, R. L., Reed, J., Teitell, M. A., & Zangle, T. A. (2022) · ACS Nano · doi:10.1021/acsnano.1c11507 · Cited by 318
Computational illumination for high-speed in vitro Fourier ptychographic microscopy
Tian, L., Liu, Z., Yeh, L.-H., Chen, M., Zhong, J., & Waller, L. (2015) · Optica · doi:10.1364/optica.2.000904 · Cited by 317
Self-citationWasisto, H. S., Prades, J. D., Gülink, J., & Waag, A. (2019) · Applied Physics Reviews · doi:10.1063/1.5096322 · Cited by 309
Metadata
- Authors
- Tian, L., & Waller, L.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2015-04-22
- Volume
- 23
- Issue
- 9
- Pages
- 11394
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2048248055
- Cited by
- 392
- References
- 9
- FWCI
- 10.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Quantitative differential phase contrast imaging in an LED array microscope. https://app.cochat.ai/papers/10.1364/oe.23.011394
- The paper
- Tian, L., & Waller, L. (2015). Quantitative differential phase contrast imaging in an LED array microscope. Optics Express. https://doi.org/10.1364/oe.23.011394
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.