The DOI matches its Crossref record; 7 of the 7 references it cites were found in a registry or an index.
Quartz-tuning-fork enhanced photothermal spectroscopy for ultra-high sensitive trace gas detection
Open accessAbstract
W/√Hz. This performance demonstrates that QEPTS can be an ultra-high sensitive technique for gas detection and shows superiority when compared to usually used methods of tunable diode laser absorption spectroscopy (TDLAS) and quartz-enhanced photoacoustic spectroscopy (QEPAS). Furthermore, when compared to an optical detector, especially a costly mercury cadmium telluride (MCT) detector with cryogenic cooling used in TDLAS, a quartz-tuning-fork is much cheap and tiny. Besides, compared to the QEPAS technique, QEPTS is a non-contact measurement technique and therefore can be used for standoff and remote trace gas detection.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2016 molecular spectroscopic database
Gordon, I. E., Rothman, L. S., Hill, C., Kochanov, R. V., Tan, Y., Bernath, P. F., Birk, M., Boudon, V., Campargue, A., Chance, K. V., et al. (2017) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2017.06.038 · Cited by 7,721
Piezoelectric tip-sample distance control for near field optical microscopes
Karrai, K., & Grober, R. D. (1995) · Applied Physics Letters · doi:10.1063/1.113340 · Cited by 968
High-speed force sensor for force microscopy and profilometry utilizing a quartz tuning fork
Giessibl, F. J. (1998) · Applied Physics Letters · doi:10.1063/1.122948 · Cited by 625
QEPAS based ppb-level detection of CO and N_2O using a high power CW DFB-QCL
Ma, Y., Lewicki, R., Razeghi, M., & Tittel, F. K. (2013) · Optics Express · doi:10.1364/oe.21.001008 · Cited by 377
Self-citationFundamental limits to force detection using quartz tuning forks
Grober, R. D., Acimovic, J., Schuck, J., Hessman, D., Kindlemann, P. J., Hespanha, J., Morse, A. S., Karrai, K., Tiemann, I., & Manus, S. (2000) · Review of Scientific Instruments · doi:10.1063/1.1150691 · Cited by 199
Intracavity quartz-enhanced photoacoustic sensor
Borri, S., Patimisco, P., Galli, I., Mazzotti, D., Giusfredi, G., Akikusa, N., Yamanishi, M., Scamarcio, G., Natale, P. D., & Spagnolo, V. (2014) · Applied Physics Letters · doi:10.1063/1.4867268 · Cited by 149
Waclawek, J. P., Moser, H., & Lendl, B. (2016) · Optics Express · doi:10.1364/oe.24.006559 · Cited by 93
Cited by
Qiao, S., He, Y., Sun, H., Patimisco, P., Sampaolo, A., Spagnolo, V., & Ma, Y. (2024) · Light: Science & Applications · doi:10.1038/s41377-024-01459-5 · Cited by 325
Self-citationLiu, X., Qiao, S., & Ma, Y. (2022) · Optics Express · doi:10.1364/oe.446294 · Cited by 97
Self-citation
Metadata
- Authors
- Ma, Y., He, Y., Tong, Y., Yu, X., & Tittel, F. K.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2018-11-20
- Volume
- 26
- Issue
- 24
- Pages
- 32103
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2901356991
- Cited by
- 354
- References
- 7
- FWCI
- 7.71
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.