The DOI matches its Crossref record.
Imaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography
Open accessAbstract
Polarization Sensitive Optical Coherence Tomography (PS- OCT) was used to image the reduction of birefringence in biological tissue due to thermal damage. Through simultaneous detection of the amplitude of signal fringes in orthogonal polarization states formed by interference of light backscattered from turbid media and a mirror in the reference arm of a Michelson interferometer, changes in the polarization due to the optical phase delay between light propagating along the fast and slow axes of birefringent media were measured. Inasmuch as fibrous structures in many biological tissues in uence the polarization state of light backscattered, PS-OCT is a potentially useful technique to image the structural properties of turbid biological materials. Birefringence of collagen, a constituent of many biological tissues, is reduced by denaturation that takes place at a temperature between 56-65 0 C, thus providing an "optical marker" for thermal damage. Images showing reduction of birefringence due to thermal damage in porcine tendon and skin are presented and demonstrate the potential of PS-OCT for burn depth assessment.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Imaging and Photodynamic Therapy: Mechanisms, Monitoring, and Optimization
Celli, J. P., Spring, B. Q., Rizvi, I., Evans, C. L., Samkoe, K. S., Verma, S., Pogue, B. W., & Hasan, T. (2010) · Chemical Reviews · doi:10.1021/cr900300p · Cited by 2,324
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Biomechanical Properties of In Vivo Human Skin From Dynamic Optical Coherence Elastography
Liang, X., & Boppart, S. A. (2010) · IEEE Transactions on Biomedical Engineering · doi:10.1109/tbme.2009.2033464 · Cited by 470
Polarization sensitive optical coherence tomography – a review [Invited]
de Boer, J. F., Hitzenberger, C. K., & Yasuno, Y. (2017) · Biomedical Optics Express · doi:10.1364/boe.8.001838 · Cited by 454
Self-citation
Metadata
- Authors
- De Boer, J., Srinivas, S., Malekafzali, A., Chen, Z., & Nelson, J.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 1998-09-14
- Volume
- 3
- Issue
- 6
- Pages
- 212
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2024444613
- Cited by
- 211
- References
- 0
- FWCI
- 5.79
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Imaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography. https://app.cochat.ai/papers/10.1364/oe.3.000212
- The paper
- De Boer, J., Srinivas, S., Malekafzali, A., Chen, Z., & Nelson, J. (1998). Imaging thermally damaged tissue by Polarization Sensitive Optical Coherence Tomography. Optics Express. https://doi.org/10.1364/oe.3.000212
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.