The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
Single-shot measurement of the intensity and phase of an arbitrary ultrashort pulse by using frequency-resolved optical gating
Abstract
We introduce a new technique, frequency-resolved optical gating, for measuring the intensity I(t) and the phase ø(t) of an individual arbitrary ultrashort pulse. Using an instantaneous nonlinear-optical interaction of two variably delayed replicas of the pulse, frequency-resolved optical gating involves measuring the spectrum of the signal pulse versus relative delay. The resulting trace, a spectrogram, yields an intuitive full-information display of the pulse. Inversion of this trace to obtain the pulse intensity and phase is equivalent to the well-known two-dimensional phase-retrieval problem and thus yields essentially unambiguous results for I(t) and ø(t).
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596
Time-frequency distributions-a review
Cohen, L. (1989) · Proceedings of the IEEE · doi:10.1109/5.30749 · Cited by 3,571
Characterization of arbitrary femtosecond pulses using frequency-resolved optical gating
Kane, D. J., & Trebino, R. (1993) · IEEE Journal of Quantum Electronics · doi:10.1109/3.199311 · Cited by 871
Self-citationTrebino, R., & Kane, D. J. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001101 · Cited by 683
Self-citationDiels, J.-C. M., Fontaine, J. J., McMichael, I. C., & Simoni, F. (1985) · Applied Optics · doi:10.1364/ao.24.001270 · Cited by 464
Koenig, W., Dunn, H. K., & Lacy, L. Y. (1946) · The Journal of the Acoustical Society of America · doi:10.1121/1.1916342 · Cited by 268
Detection, estimation, and classification with spectrograms
Altes, R. A. (1980) · The Journal of the Acoustical Society of America · doi:10.1121/1.384165 · Cited by 264
Signal reconstruction from short-time Fourier transform magnitude
Nawab, S. H., Quatieri, T. F., & Lim, J. S. (1983) · IEEE Transactions on Acoustics Speech and Signal Processing · doi:10.1109/tassp.1983.1164162 · Cited by 226
The chronocyclic representation of ultrashort light pulses
Paye, J. (1992) · IEEE Journal of Quantum Electronics · doi:10.1109/3.159533 · Cited by 135
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Trebino, R., DeLong, K. W., Fittinghoff, D. N., Sweetser, J. N., Krumbügel, M. A., Richman, B. A., & Kane, D. J. (1997) · Review of Scientific Instruments · doi:10.1063/1.1148286 · Cited by 1,494
Self-citationDispersive Fourier transformation for fast continuous single-shot measurements
Goda, K., & Jalali, B. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.359 · Cited by 1,007
Trebino, R., & Kane, D. J. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.001101 · Cited by 683
Self-citationSilicon-chip-based ultrafast optical oscilloscope
Foster, M. A., Salem, R., Geraghty, D. F., Turner-Foster, A. C., Lipson, M., & Gaeta, A. L. (2008) · Nature · doi:10.1038/nature07430 · Cited by 480
Metadata
- Authors
- Kane, D. J., & Trebino, R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1993-05-15
- Volume
- 18
- Issue
- 10
- Pages
- 823
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2158828207
- Cited by
- 503
- References
- 9
- FWCI
- 14.97
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.