Chronocyclic tomography for measuring the amplitude and phase structure of optical pulses
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We describe a new method—chronocyclic tomography—for determining the amplitude and phase structure of a short optical pulse. The technique is based on measurements of the energy spectrum of the pulse after it has passed through a time–frequency-domain imaging system. Tomographic inversion of these measured spectra yields the time–frequency Wigner distribution of the pulse, which uniquely determines the amplitude and phase structure.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Smithey, D. T., Beck, M., Raymer, M. G., & Faridani, A. (1993) · Physical Review Letters · doi:10.1103/physrevlett.70.1244 · Cited by 1,538
Self-citation
Cited by
Krausz, F., & Ivanov, M. (2009) · Reviews of Modern Physics · doi:10.1103/revmodphys.81.163 · Cited by 5,468
Digital computation of the fractional Fourier transform
Ozaktas, H. M., Arikan, O., Kutay, M. A., & Bozdagt, G. (1996) · IEEE Transactions on Signal Processing · doi:10.1109/78.536672 · Cited by 1,187
Preparation of nonclassical states in cavities with a moving mirror
Bose, S., Jacobs, K., & Knight, P. L. (1997) · Physical Review A · doi:10.1103/physreva.56.4175 · Cited by 495
Femtosecond optical pulse shaping and processing
Weiner, A. M. (1995) · Progress in Quantum Electronics · doi:10.1016/0079-6727(94)00013-o · Cited by 458
Frequency-resolved optical gating with the use of second-harmonic generation
DeLong, K. W., Trebino, R., Hunter, J., & White, W. E. (1994) · Journal of the Optical Society of America B · doi:10.1364/josab.11.002206 · Cited by 433
Characterization of ultrashort electromagnetic pulses
Walmsley, I. A., & Dorrer, C. (2009) · Advances in Optics and Photonics · doi:10.1364/aop.1.000308 · Cited by 403
Self-citationComplex wave-field reconstruction using phase-space tomography
Raymer, M. G., Beck, M., & McAlister, D. (1994) · Physical Review Letters · doi:10.1103/physrevlett.72.1137 · Cited by 348
Self-citationOptimal filtering in fractional Fourier domains
Kutay, A., Ozaktas, H. M., Ankan, O., & Onural, L. (1997) · IEEE Transactions on Signal Processing · doi:10.1109/78.575688 · Cited by 298
Roadmap on quantum light spectroscopy
Mukamel, S., Freyberger, M., Schleich, W., Bellini, M., Zavatta, A., Leuchs, G., Silberhorn, C., Boyd, R. W., Sánchez-Soto, L. L., Stefanov, A., et al. (2020) · Journal of Physics B: Atomic, Molecular and Optical Physics · doi:10.1088/1361-6455/ab69a8 · Cited by 178
Self-citationWigner functions in optics: describing beams as ray bundles and pulses as particle ensembles
Alonso, M. A. (2011) · Advances in Optics and Photonics · doi:10.1364/aop.3.000272 · Cited by 174
introduction to the fractional fourier transform and its applications
Ozaktas, H. M., Kutay, M. A., & Mendlovic, D. (1999) · Advances in Imaging and Electron Physics · doi:10.1016/s1076-5670(08)70272-6 · Cited by 164
Metadata
- Authors
- Beck, M., Walmsley, I. A., Wong, V., & Raymer, M. G.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1993-12-01
- Volume
- 18
- Issue
- 23
- Pages
- 2041
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2131789080
- Cited by
- 107
- References
- 1
- FWCI
- 5.40
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.