The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Optical coherence tomography using a frequency-tunable optical source
Abstract
We have developed a simple, wide-optical-bandwidth, high-resolution system for performing rapid optical frequency domain reflectometry measurements and applied it to multidimensional tomographic imaging. The source is a grating-tuned external cavity semiconductor laser with a tuning capability of 25 nm in 100 ms. We discuss system performance and show a two-dimensional optical coherence tomography image of a thin glass sandwich structure as a preliminary demonstration of the systems depth and resolution capabilities.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
Self-citationUttam, D., & Culshaw, B. (1985) · Journal of Lightwave Technology · doi:10.1109/jlt.1985.1074315 · Cited by 242
Experimental and theoretical investigations of coherent OFDR with semiconductor laser sources
Passy, R., Gisin, N., von der Weid, J. P., & Gilgen, H. H. (1994) · Journal of Lightwave Technology · doi:10.1109/50.320946 · Cited by 182
Cited by
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Optical coherence tomography – current and future applications
Adhi, M., & Duker, J. S. (2013) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e32835f8bf8 · Cited by 567
Optical coherence tomography: Imaging of the choroid and beyond
Mrejen, S., & Spaide, R. F. (2013) · Survey of Ophthalmology · doi:10.1016/j.survophthal.2012.12.001 · Cited by 477
Optical coherence tomography (OCT): principle and technical realization
Aumann, S., Donner, S., Fischer, J., & Müller, F. (2019) · High Resolution Imaging in Microscopy and Ophthalmology · doi:10.1007/978-3-030-16638-0_3 · Cited by 449
Optical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Metadata
- Authors
- Chinn, S. R., Swanson, E. A., & Fujimoto, J. G.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1997-03-01
- Volume
- 22
- Issue
- 5
- Pages
- 340
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2066456957
- Cited by
- 666
- References
- 3
- FWCI
- 5.78
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Optical coherence tomography using a frequency-tunable optical source. https://app.cochat.ai/papers/10.1364/ol.22.000340
- The paper
- Chinn, S. R., Swanson, E. A., & Fujimoto, J. G. (1997). Optical coherence tomography using a frequency-tunable optical source. Optics Letters. https://doi.org/10.1364/ol.22.000340
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.