The DOI matches its Crossref record.
In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography
Abstract
We describe a novel optical system for bidirectional color Doppler imaging of flow in biological tissues with micrometer-scale resolution and demonstrate its use for in vivo imaging of blood flow in an animal model. Our technique, color Doppler optical coherence tomography (CDOCT), performs spatially localized optical Doppler velocimetry by use of scanning low-coherence interferometry. CDOCT is an extension of optical coherence tomography (OCT), employing coherent signal-acquisition electronics and joint time-frequency analysis algorithms to perform flow imaging simultaneous with conventional OCT imaging. Cross-sectional maps of blood flow velocity with <50-microm spatial resolution and <0.6-mm/s velocity precision were obtained through intact skin in living hamster subdermal tissue. This technology has several potential medical applications.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Vakoc, B. J., Lanning, R. M., Tyrrell, J. A., Padera, T. P., Bartlett, L. A., Stylianopoulos, T., Munn, L. L., Tearney, G. J., Fukumura, D., Jain, R. K., et al. (2009) · Nature Medicine · doi:10.1038/nm.1971 · Cited by 719
Park, D.-W., Schendel, A. A., Mikael, S., Brodnick, S. K., Richner, T. J., Ness, J. P., Hayat, M. R., Atry, F., Frye, S. T., Pashaie, R., et al. (2014) · Nature Communications · doi:10.1038/ncomms6258 · Cited by 565
Optical coherence tomography – current and future applications
Adhi, M., & Duker, J. S. (2013) · Current Opinion in Ophthalmology · doi:10.1097/icu.0b013e32835f8bf8 · Cited by 567
Doppler Optical Coherence Tomography
Leitgeb, R. A., Werkmeister, R. M., Blatter, C., & Schmetterer, L. (2014) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2014.03.004 · Cited by 444
Spectral-domain phase microscopy
Choma, M. A., Ellerbee, A. K., Yang, C., Creazzo, T. L., & Izatt, J. A. (2005) · Optics Letters · doi:10.1364/ol.30.001162 · Cited by 342
Self-citation
Metadata
- Authors
- Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1997-09-15
- Volume
- 22
- Issue
- 18
- Pages
- 1439
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2077026901
- Cited by
- 609
- References
- 0
- FWCI
- 13.50
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography. https://app.cochat.ai/papers/10.1364/ol.22.001439
- The paper
- Izatt, J. A., Kulkarni, M. D., Yazdanfar, S., Barton, J. K., & Welch, A. J. (1997). In vivo bidirectional color Doppler flow imaging of picoliter blood volumes using optical coherence tomography. Optics Letters. https://doi.org/10.1364/ol.22.001439
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.