The DOI matches its Crossref record.
Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design
Abstract
We report on the design and initial clinical experience with a real-time endoscopic optical coherence tomography (EOCT) imaging system. The EOCT unit includes a high-speed optical coherence tomography interferometer, endoscope-compatible catheter probes, and real-time data capture and display hardware and software. Several technological innovations are introduced that improve EOCT efficiency and performance. In initial clinical studies using the EOCT system, the esophagus, stomach, duodenum, ileum, colon, and rectum of patients with normal endoscopic findings were examined. In these initial investigations, EOCT imaging clearly delineated the substructure of the mucosa and submucosa in several gastrointestinal organs; microscopic structures such as glands, blood vessels, pits, villi, and crypts were also observed.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Optical coherence tomography for ultrahigh resolution in vivo imaging
Fujimoto, J. G. (2003) · Nature Biotechnology · doi:10.1038/nbt892 · Cited by 1,033
Optical coherence tomography: a review of clinical development from bench to bedside
Zysk, A. M., Nguyen, F. T., Oldenburg, A. L., Marks, D. L., & Boppart, S. A. (2007) · Journal of Biomedical Optics · doi:10.1117/1.2793736 · Cited by 547
Nano-optic endoscope for high-resolution optical coherence tomography in vivo
Pahlevaninezhad, H., Khorasaninejad, M., Huang, Y.-W., Shi, Z., Hariri, L. P., Adams, D. C., Ding, V., Zhu, A., Qiu, C.-W., Capasso, F., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0224-2 · Cited by 412
Ultrahigh-resolution full-field optical coherence tomography
Dubois, A., Grieve, K., Moneron, G., Lecaque, R., Vabre, L., & Boccara, C. (2004) · Applied Optics · doi:10.1364/ao.43.002874 · Cited by 394
Metadata
- Authors
- Rollins, A. M., Ung-arunyawee, R., Chak, A., Wong, R. C. K., Kobayashi, K., Sivak, M. V., & Izatt, J. A.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 1999-10-01
- Volume
- 24
- Issue
- 19
- Pages
- 1358
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2034849974
- Cited by
- 181
- References
- 0
- FWCI
- 14.01
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design. https://app.cochat.ai/papers/10.1364/ol.24.001358
- The paper
- Rollins, A. M., Ung-arunyawee, R., Chak, A., Wong, R. C. K., Kobayashi, K., Sivak, M. V., & Izatt, J. A. (1999). Real-time in vivo imaging of human gastrointestinal ultrastructure by use of endoscopic optical coherence tomography with a novel efficient interferometer design. Optics Letters. https://doi.org/10.1364/ol.24.001358
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.