The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Local plasmon sensor with gold colloid monolayers deposited upon glass substrates
Abstract
A new optical sensor that uses local plasmon resonance is proposed. A peak that is due to the local plasmon resonance appears in the absorption spectrum of a gold colloid suspension in the visible region, and its height and wavelength depend on the refractive index of the suspension. These properties are used for optical sensors. We used gold colloid monolayers in which colloidal gold particles a few tens of nanometers in diameter were immobilized upon a glass slide by a functional organic coupling agent. We measured the absorption spectra of the the gold colloid monolayers, which were immersed in liquid samples or coated with thin films. We observed increases of both the resonance wavelength and the absorbance as the refractive indices of the sample liquids or the thickness of the coated films increased. The proportional constants of the resonance wavelength to the film thickness were 3.6 and 5.7 for a 13.9- and a 20.2-nm gold colloid monolayer, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Self-Assembled Metal Colloid Monolayers: An Approach to SERS Substrates
Freeman, R. G., Grabar, K. C., Allison, K. J., Bright, R. M., Davis, J. A., Guthrie, A. P., Hommer, M. B., Jackson, M. A., Smith, P. C., Walter, D. G., et al. (1995) · Science · doi:10.1126/science.267.5204.1629 · Cited by 1,289
Grabar, K. C., Smith, P. C., Musick, M. D., Davis, J. A., Walter, D. G., Jackson, M. A., Guthrie, A. P., & Natan, M. J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja952233+ · Cited by 504
Cited by
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Larsson, E. M., Alegret, J., Käll, M., & Sutherland, D. S. (2007) · Nano Letters · doi:10.1021/nl0701612 · Cited by 699
Localized Surface Plasmon Resonance Biosensors
Zhao, J., Zhang, X., Yonzon, C. R., Haes, A. J., & Van Duyne, R. P. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.219 · Cited by 508
Metadata
- Authors
- Okamoto, T., Yamaguchi, I., & Kobayashi, T.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2000-03-15
- Volume
- 25
- Issue
- 6
- Pages
- 372
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2102272800
- Cited by
- 417
- References
- 3
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Local plasmon sensor with gold colloid monolayers deposited upon glass substrates. https://app.cochat.ai/papers/10.1364/ol.25.000372
- The paper
- Okamoto, T., Yamaguchi, I., & Kobayashi, T. (2000). Local plasmon sensor with gold colloid monolayers deposited upon glass substrates. Optics Letters. https://doi.org/10.1364/ol.25.000372
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.