The DOI matches its Crossref record; 3 of the 3 references it cites were found in a registry or an index.
Local plasmon sensor with gold colloid monolayers deposited upon glass substrates
Abstract
A new optical sensor that uses local plasmon resonance is proposed. A peak that is due to the local plasmon resonance appears in the absorption spectrum of a gold colloid suspension in the visible region, and its height and wavelength depend on the refractive index of the suspension. These properties are used for optical sensors. We used gold colloid monolayers in which colloidal gold particles a few tens of nanometers in diameter were immobilized upon a glass slide by a functional organic coupling agent. We measured the absorption spectra of the the gold colloid monolayers, which were immersed in liquid samples or coated with thin films. We observed increases of both the resonance wavelength and the absorbance as the refractive indices of the sample liquids or the thickness of the coated films increased. The proportional constants of the resonance wavelength to the film thickness were 3.6 and 5.7 for a 13.9- and a 20.2-nm gold colloid monolayer, respectively.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Controlled Nucleation for the Regulation of the Particle Size in Monodisperse Gold Suspensions
FRENS, G. (1973) · Nature Physical Science · doi:10.1038/physci241020a0 · Cited by 8,336
Self-Assembled Metal Colloid Monolayers: An Approach to SERS Substrates
Freeman, R. G., Grabar, K. C., Allison, K. J., Bright, R. M., Davis, J. A., Guthrie, A. P., Hommer, M. B., Jackson, M. A., Smith, P. C., Walter, D. G., et al. (1995) · Science · doi:10.1126/science.267.5204.1629 · Cited by 1,289
Grabar, K. C., Smith, P. C., Musick, M. D., Davis, J. A., Walter, D. G., Jackson, M. A., Guthrie, A. P., & Natan, M. J. (1996) · Journal of the American Chemical Society · doi:10.1021/ja952233+ · Cited by 504
Cited by
The golden age: gold nanoparticles for biomedicine
Dreaden, E. C., Alkilany, A. M., Huang, X., Murphy, C. J., & El-Sayed, M. A. (2012) · Chem. Soc. Rev. · doi:10.1039/c1cs15237h · Cited by 3,550
Haes, A. J., & Van Duyne, R. P. (2002) · Journal of the American Chemical Society · doi:10.1021/ja020393x · Cited by 2,057
Ultrafast Plasmon-Induced Electron Transfer from Gold Nanodots into TiO2 Nanoparticles
Furube, A., Du, L., Hara, K., Katoh, R., & Tachiya, M. (2007) · Journal of the American Chemical Society · doi:10.1021/ja076134v · Cited by 972
Nath, N., & Chilkoti, A. (2002) · Analytical Chemistry · doi:10.1021/ac015657x · Cited by 918
Localized Surface Plasmon Resonance Spectroscopy of Single Silver Triangular Nanoprisms
Sherry, L. J., Jin, R., Mirkin, C. A., Schatz, G. C., & Van Duyne, R. P. (2006) · Nano Letters · doi:10.1021/nl061286u · Cited by 897
Local Refractive Index Dependence of Plasmon Resonance Spectra from Individual Nanoparticles
Mock, J. J., Smith, D. R., & Schultz, S. (2003) · Nano Letters · doi:10.1021/nl0340475 · Cited by 839
Larsson, E. M., Alegret, J., Käll, M., & Sutherland, D. S. (2007) · Nano Letters · doi:10.1021/nl0701612 · Cited by 699
A unified view of propagating and localized surface plasmon resonance biosensors
Haes, A. J., & Van Duyne, R. P. (2004) · Analytical and Bioanalytical Chemistry · doi:10.1007/s00216-004-2708-9 · Cited by 666
Localized Surface Plasmon Resonances in Aluminum Nanodisks
Langhammer, C., Schwind, M., Kasemo, B., & Zorić, I. (2008) · Nano Letters · doi:10.1021/nl080453i · Cited by 588
Nath, N., & Chilkoti, A. (2004) · Analytical Chemistry · doi:10.1021/ac049741z · Cited by 514
Localized Surface Plasmon Resonance Biosensors
Zhao, J., Zhang, X., Yonzon, C. R., Haes, A. J., & Van Duyne, R. P. (2006) · Nanomedicine · doi:10.2217/17435889.1.2.219 · Cited by 508
Jeong, Y., Kook, Y.-M., Lee, K., & Koh, W.-G. (2018) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2018.04.007 · Cited by 479
Surface plasmon resonance based biosensor technique: A review
Guo, X. (2012) · Journal of Biophotonics · doi:10.1002/jbio.201200015 · Cited by 436
Surface Plasmon Resonance for Biosensing: A Mini-Review
Abdulhalim, I., Zourob, M., & Lakhtakia, A. (2008) · Electromagnetics · doi:10.1080/02726340801921650 · Cited by 410
Nanoparticle labels in immunosensing using optical detection methods
Seydack, M. (2005) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2004.11.003 · Cited by 314
Derkachova, A., Kolwas, K., & Demchenko, I. (2016) · Plasmonics · doi:10.1007/s11468-015-0128-7 · Cited by 288
Biological applications of localised surface plasmonic phenomenae
Stuart, D. A., Haes, A. J., Yonzon, C. R., Hicks, E. M., & Van Duyne, R. P. (2005) · IEE Proceedings - Nanobiotechnology · doi:10.1049/ip-nbt:20045012 · Cited by 283
Plasmonics: visit the past to know the future
Hayashi, S., & Okamoto, T. (2012) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/45/43/433001 · Cited by 278
Self-citationCavity QED treatment of interactions between a metal nanoparticle and a dipole emitter
Waks, E., & Sridharan, D. (2010) · Physical Review A · doi:10.1103/physreva.82.043845 · Cited by 268
Sensing capability of the localized surface plasmon resonance of gold nanorods
Chen, C.-D., Cheng, S.-F., Chau, L.-K., & Wang, C. R. C. (2007) · Biosensors and Bioelectronics · doi:10.1016/j.bios.2006.03.021 · Cited by 254
Metadata
- Authors
- Okamoto, T., Yamaguchi, I., & Kobayashi, T.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2000-03-15
- Volume
- 25
- Issue
- 6
- Pages
- 372
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2102272800
- Cited by
- 417
- References
- 3
- FWCI
- 5.87
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.