The DOI matches its Crossref record; 8 of the 8 references it cites were found in a registry or an index.
Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation
Abstract
We present a normalized Born expansion that facilitates fluorescence reconstructions in turbid, tissuelike media. The algorithm can be particularly useful for tissue investigations of fluorochrome distributionin vivo, since it does not require absolute photon-field measurements or measurements before contrast-agent administration. This unique advantage can be achieved only in fluorescence mode. We used this algorithm to three-dimensionally image and quantify an indocyanine fluorochrome phantom, using a novel fluorescence tomographic imager developed for animals.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
In vivo imaging of tumors with protease-activated near-infrared fluorescent probes
Weissleder, R., Tung, C.-H., Mahmood, U., & Bogdanov, A. (1999) · Nature Biotechnology · doi:10.1038/7933 · Cited by 1,591
Self-citationConcurrent MRI and diffuse optical tomography of breast after indocyanine green enhancement
Ntziachristos, V., Yodh, A. G., Schnall, M., & Chance, B. (2000) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.040570597 · Cited by 793
Self-citationKienle, A., & Patterson, M. S. (1997) · Journal of the Optical Society of America A · doi:10.1364/josaa.14.000246 · Cited by 474
Experimental images of heterogeneous turbid media by frequency-domain diffusing-photon tomography
O’Leary, M. A., Boas, D. A., Chance, B., & Yodh, A. G. (1995) · Optics Letters · doi:10.1364/ol.20.000426 · Cited by 440
Fishkin, J. B., & Gratton, E. (1993) · Journal of the Optical Society of America A · doi:10.1364/josaa.10.000127 · Cited by 385
Novel Receptor-Targeted Fluorescent Contrast Agents for In Vivo Tumor Imaging
Achilefu, S. A., Dorshow, R. B., Bugaj, J. E., & Rajagopalan, R. (2000) · Investigative Radiology · doi:10.1097/00004424-200008000-00004 · Cited by 310
Licha, K., Riefke, B., Ntziachristos, V., Becker, A., Chance, B., & Semmler, W. (2007) · Photochemistry and Photobiology · doi:10.1562/0031-8655(2000)0720392hcdaca2.0.co2 · Cited by 238
Self-citationDiffuse optical tomography of highly heterogeneous media
Ntziachristos, V., Hielscher, A. H., Yodh, A. G., et al. (2001) · IEEE Transactions on Medical Imaging · doi:10.1109/42.929613 · Cited by 72
Self-citation
Cited by
In vivo near-infrared fluorescence imaging
Frangioni, J. V. (2003) · Current Opinion in Chemical Biology · doi:10.1016/j.cbpa.2003.08.007 · Cited by 2,653
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Self-citationLooking and listening to light: the evolution of whole-body photonic imaging
Ntziachristos, V., Ripoll, J., Wang, L. V., & Weissleder, R. (2005) · Nature Biotechnology · doi:10.1038/nbt1074 · Cited by 1,557
Self-citationDiffuse optics for tissue monitoring and tomography
Durduran, T., Choe, R., Baker, W. B., & Yodh, A. G. (2010) · Reports on Progress in Physics · doi:10.1088/0034-4885/73/7/076701 · Cited by 1,161
Fluorescence molecular tomography resolves protease activity in vivo
Ntziachristos, V., Tung, C.-H., Bremer, C., & Weissleder, R. (2002) · Nature Medicine · doi:10.1038/nm729 · Cited by 827
Self-citation
Metadata
- Authors
- Ntziachristos, V., & Weissleder, R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2001-06-15
- Volume
- 26
- Issue
- 12
- Pages
- 893
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2047615998
- Cited by
- 475
- References
- 8
- FWCI
- 19.92
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation. https://app.cochat.ai/papers/10.1364/ol.26.000893
- The paper
- Ntziachristos, V., & Weissleder, R. (2001). Experimental three-dimensional fluorescence reconstruction of diffuse media by use of a normalized Born approximation. Optics Letters. https://doi.org/10.1364/ol.26.000893
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.