The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Noninvasive monitoring of glucose concentration with optical coherence tomography
Abstract
We have proposed a tested in tissue phantoms and in vivo a novel sensor based on optical coherence tomography (OCT) for noninvasive and continuous monitoring of blood glucose concentration. OCT images were obtained from pig and rabbit skin before and after glucose administration. Slopes of OCT signals decreased substantially (~40% in tissues in vivo) and linearly with the increase of blood glucose concentration from 4 to 30 mM, typical for normal and diabetic subjects. Phantom studies demonstrated 1% accuracy of scattering-coefficient measurement. Our theoretical and experimental studies suggest that glucose concentration can potentially be measured noninvasively with high sensitivity and accuracy with OCT systems.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
STATISTICAL METHODS FOR ASSESSING AGREEMENT BETWEEN TWO METHODS OF CLINICAL MEASUREMENT
Martin Bland, J., & Altman, D. (1986) · The Lancet · doi:10.1016/s0140-6736(86)90837-8 · Cited by 47,965
Capes, S. E., Hunt, D., Malmberg, K., & Gerstein, H. C. (2000) · The Lancet · doi:10.1016/s0140-6736(99)08415-9 · Cited by 2,187
Capes, S. E., Hunt, D., Malmberg, K., Pathak, P., & Gerstein, H. C. (2001) · Stroke · doi:10.1161/hs1001.096194 · Cited by 1,824
McCowen, K. C., Malhotra, A., & Bistrian, B. R. (2001) · Critical Care Clinics · doi:10.1016/s0749-0704(05)70154-8 · Cited by 1,170
Effect of Severe Burn Injury on Substrate Cycling by Glucose and Fatty Acids
Wolfe, R. R., Herndon, D. N., Jahoor, F., Miyoshi, H., & Wolfe, M. (1987) · New England Journal of Medicine · doi:10.1056/nejm198708133170702 · Cited by 467
WANG, P. (1993) · The Lancet · doi:10.1016/0140-6736(93)90816-y · Cited by 446
Cited by
Glucose sensors: a review of current and emerging technology
Oliver, N. S., Toumazou, C., Cass, A. E. G., & Johnston, D. G. (2009) · Diabetic Medicine · doi:10.1111/j.1464-5491.2008.02642.x · Cited by 584
Noninvasive Blood Glucose Monitoring With Optical Coherence Tomography
Larin, K. V., Eledrisi, M. S., Motamedi, M., & Esenaliev, R. O. (2002) · Diabetes Care · doi:10.2337/diacare.25.12.2263 · Cited by 293
Self-citationOptical coherence tomography – development, principles, applications
Fercher, A. F. (2010) · Zeitschrift für Medizinische Physik · doi:10.1016/j.zemedi.2009.11.002 · Cited by 259
Non-Invasive Glucose Measurement Technologies: An Update from 1999 to the Dawn of the New Millennium
Khalil, O. S. (2004) · Diabetes Technology & Therapeutics · doi:10.1089/dia.2004.6.660 · Cited by 255
Ozana, N., Arbel, N., Beiderman, Y., Mico, V., Sanz, M., Garcia, J., Anand, A., Javidi, B., Epstein, Y., & Zalevsky, Z. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.001926 · Cited by 81
Metadata
- Authors
- Esenaliev, R. O., Larin, K. V., Larina, I. V., & Motamedi, M.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2001-07-01
- Volume
- 26
- Issue
- 13
- Pages
- 992
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1999692412
- Cited by
- 204
- References
- 6
- FWCI
- 5.24
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Noninvasive monitoring of glucose concentration with optical coherence tomography. https://app.cochat.ai/papers/10.1364/ol.26.000992
- The paper
- Esenaliev, R. O., Larin, K. V., Larina, I. V., & Motamedi, M. (2001). Noninvasive monitoring of glucose concentration with optical coherence tomography. Optics Letters. https://doi.org/10.1364/ol.26.000992
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.