The DOI matches its Crossref record; 9 of the 9 references it cites were found in a registry or an index.
High-resolution optical coherence tomography over a large depth range with an axicon lens
Open accessAbstract
In optical coherence tomography, axial and lateral resolutions are determined by the source coherence length and the numerical aperture of the sampling lens, respectively. Whereas axial resolution can be improved by use of a broadband light source, there is a trade-off between lateral resolution and focusing depth when conventional optical elements are used. We report on the incorporation of an axicon lens into the sample arm of an interferometer to overcome this limitation. Using an axicon lens with a top angle of 160 degrees , we maintained 10-microm or better lateral resolution over a focusing depth of at least 6 mm. In addition to having high lateral resolution, the focusing spot has an intensity that is approximately constant over a greater depth range than when a conventional lens is used.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Huang, D., Swanson, E. A., Lin, C. P., Schuman, J. S., Stinson, W. G., Chang, W., Hee, M. R., Flotte, T., Gregory, K., Puliafito, C. A., et al. (1991) · Science · doi:10.1126/science.1957169 · Cited by 13,788
The Axicon: A New Type of Optical Element
McLeod, J. H. (1954) · Journal of the Optical Society of America · doi:10.1364/josa.44.000592 · Cited by 970
In vivo ultrahigh-resolution optical coherence tomography
Drexler, W., Morgner, U., Käertner, F. X., Pitris, C., Boppart, S. A., Li, X. D., Ippen, E. P., & Fujimoto, J. G. (1999) · Optics Letters · doi:10.1364/ol.24.001221 · Cited by 945
Hartl, I., Li, X. D., Chudoba, C., Ghanta, R. K., Ko, T. H., Fujimoto, J. G., Ranka, J. K., & Windeler, R. S. (2001) · Optics Letters · doi:10.1364/ol.26.000608 · Cited by 852
Production and uses of diffractionless beams
Herman, R. M., & Wiggins, T. A. (1991) · Journal of the Optical Society of America A · doi:10.1364/josaa.8.000932 · Cited by 561
Zhao, Y., Chen, Z., Saxer, C., Xiang, S., de Boer, J. F., & Nelson, J. S. (2000) · Optics Letters · doi:10.1364/ol.25.000114 · Cited by 559
Self-citationOptical Doppler tomographic imaging of fluid flow velocity in highly scattering media
Chen, Z., Milner, T. E., Dave, D., & Nelson, J. S. (1997) · Optics Letters · doi:10.1364/ol.22.000064 · Cited by 443
Self-citationRollins, A. M., Ung-arunyawee, R., Chak, A., Wong, R. C. K., Kobayashi, K., Sivak, M. V., & Izatt, J. A. (1999) · Optics Letters · doi:10.1364/ol.24.001358 · Cited by 181
Chen, Z., Zhao, Y., Srinivas, S. M., Nelson, J. S., Prakash, N., & Frostig, R. D. (1999) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/2944.796340 · Cited by 160
Self-citation
Cited by
Liu, L., Gardecki, J. A., Nadkarni, S. K., Toussaint, J. D., Yagi, Y., Bouma, B. E., & Tearney, G. J. (2011) · Nature Medicine · doi:10.1038/nm.2409 · Cited by 463
Dubois, A., Levecq, O., Azimani, H., Siret, D., Barut, A., Suppa, M., del Marmol, V., Malvehy, J., Cinotti, E., Rubegni, P., et al. (2018) · Journal of Biomedical Optics · doi:10.1117/1.jbo.23.10.106007 · Cited by 269
High-performance axicon lenses based on high-contrast, multilayer gratings
Doshay, S., Sell, D., Yang, J., Yang, R., & Fan, J. A. (2018) · APL Photonics · doi:10.1063/1.5009760 · Cited by 9
Metadata
- Authors
- Ding, Z., Ren, H., Zhao, Y., Nelson, J. S., & Chen, Z.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2002-02-15
- Volume
- 27
- Issue
- 4
- Pages
- 243
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2073249634
- Cited by
- 367
- References
- 9
- FWCI
- 4.31
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.