The DOI matches its Crossref record; 11 of the 11 references it cites were found in a registry or an index.
Two-photon imaging to a depth of 1000 µm in living brains by use of a Ti:Al_2O_3 regenerative amplifier
Abstract
It is shown that two-photon fluorescence images can be obtained throughout almost the entire gray matter of the mouse neocortex by using optically amplified femtosecond pulses. The achieved imaging depth approaches the theoretical limit set by excitation of out-of-focus fluorescence.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Two-photon laser scanning fluorescence microscopy
Denk, W., Strickler, J. H., & Webb, W. W. (1990) · Science · doi:10.1126/science.2321027 · Cited by 9,488
Self-citationKleinfeld, D., Mitra, P. P., Helmchen, F., & Denk, W. (1998) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.95.26.15741 · Cited by 832
Self-citationHighly Nonlinear Photodamage in Two-Photon Fluorescence Microscopy
Hopt, A., & Neher, E. (2001) · Biophysical Journal · doi:10.1016/s0006-3495(01)76173-5 · Cited by 442
Anatomical and functional imaging of neurons using 2-photon laser scanning microscopy
Denk, W., Delaney, K. R., Gelperin, A., Kleinfeld, D., Strowbridge, B. W., Tank, D. W., & Yuste, R. (1994) · Journal of Neuroscience Methods · doi:10.1016/0165-0270(94)90189-9 · Cited by 348
Self-citationCa2+ Fluorescence Imaging with Pico- and Femtosecond Two-Photon Excitation: Signal and Photodamage
Koester, H. J., Baur, D., Uhl, R., & Hell, S. W. (1999) · Biophysical Journal · doi:10.1016/s0006-3495(99)77063-3 · Cited by 264
König, K., Becker, T. W., Fischer, P., Riemann, I., & Halbhuber, K.-J. (1999) · Optics Letters · doi:10.1364/ol.24.000113 · Cited by 259
Spread of dendritic excitation in layer 2/3 pyramidal neurons in rat barrel cortex in vivo
Svoboda, K., Helmchen, F., Denk, W., & Tank, D. W. (1999) · Nature Neuroscience · doi:10.1038/4569 · Cited by 258
Self-citationKrestel, H. E. (2001) · Nucleic Acids Research · doi:10.1093/nar/29.7.e39 · Cited by 195
New developments in multiphoton microscopy
Helmchen, F., & Denk, W. T. (2002) · Current Opinion in Neurobiology · doi:10.1016/s0959-4388(02)00362-8 · Cited by 144
Self-citationUltra-deep two-photon fluorescence excitation in turbid media
Beaurepaire, E., Oheim, M., & Mertz, J. C. (2001) · Optics Communications · doi:10.1016/s0030-4018(00)01156-1 · Cited by 138
Dispersion pre‐compensation of 15 femtosecond optical pulses for high‐numerical‐aperture objectives
Müller, Squier, Wolleschensky, et al. (1998) · Journal of Microscopy · doi:10.1046/j.1365-2818.1998.00357.x · Cited by 103
Cited by
Deep tissue two-photon microscopy
Helmchen, F., & Denk, W. (2005) · Nature Methods · doi:10.1038/nmeth818 · Cited by 4,153
Self-citationIn vivo three-photon microscopy of subcortical structures within an intact mouse brain
Horton, N. G., Wang, K., Kobat, D., Clark, C. G., Wise, F. W., Schaffer, C. B., & Xu, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2012.336 · Cited by 1,505
Grienberger, C., & Konnerth, A. (2012) · Neuron · doi:10.1016/j.neuron.2012.02.011 · Cited by 1,354
Richardson, D. S., & Lichtman, J. W. (2015) · Cell · doi:10.1016/j.cell.2015.06.067 · Cited by 1,095
Through-skull fluorescence imaging of the brain in a new near-infrared window
Hong, G., Diao, S., Chang, J., Antaris, A. L., Chen, C., Zhang, B., Zhao, S., Atochin, D. N., Huang, P. L., Andreasson, K. I., et al. (2014) · Nature Photonics · doi:10.1038/nphoton.2014.166 · Cited by 1,061
Metadata
- Authors
- Theer, P., Hasan, M. T., & Denk, W.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2003-06-15
- Volume
- 28
- Issue
- 12
- Pages
- 1022
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1966187182
- Cited by
- 645
- References
- 11
- FWCI
- 11.22
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.