The DOI matches its Crossref record.
In vivo photoacoustic flow cytometry for monitoring of circulating single cancer cells and contrast agents
Abstract
A new photoacoustic flow cytometry was developed for real-time detection of circulating cells, nanoparticles, and contrast agents in vivo. Its capability, integrated with photothermal and optical clearing methods, was demonstrated using a near-infrared tunable laser to characterize the in vivo kinetics of Indocyanine Green alone and single cancer cells labeled with gold nanorods and Indocyanine Green in the vasculature of the mouse ear. In vivo applications are discussed, including selective nanophotothermolysis of metastatic squamous cells, label-free detection of melanoma cells, study of pharmokinetics, and immune response to apoptotic and necrotic cells, with potential translation to humans. The threshold sensitivity is estimated as one cancer cell in the background of 10(7) normal blood cells.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
No references could be resolved yet.
Research works printed but not linked: 5
- Novak, 2004, Opt. Lett., 29, 77, 10.1364/OL.29.000077 · DOI · Paper page
- Zharov, 2004, Proc. SPIE, 5320, 256
- Zharov, 2006, J. Cell. Biochem., 97, 916, 10.1002/jcb.20766 · doi:10.1002/jcb.20766
- Wang, 2004, Opt. Lett., 29, 730, 10.1364/OL.29.000730 · doi:10.1364/ol.29.000730
- Wei, 2003, Invest. Ophthalmol. Visual Sci., 44, 4489, 10.1167/iovs.03-0041 · doi:10.1167/iovs.03-0041
Cited by
Golden carbon nanotubes as multimodal photoacoustic and photothermal high-contrast molecular agents
Kim, J.-W., Galanzha, E. I., Shashkov, E. V., Moon, H.-M., & Zharov, V. P. (2009) · Nature Nanotechnology · doi:10.1038/nnano.2009.231 · Cited by 710
Self-citationTransverse flow imaging based on photoacoustic Doppler bandwidth broadening
Yao, J., & Wang, L. V. (2010) · Journal of Biomedical Optics · doi:10.1117/1.3339953 · Cited by 75
Wang, H., Liao, R., Xiong, Z., Wang, Z., Li, J., Zhou, Q., Tao, Y., & Ma, H. (2022) · Biosensors · doi:10.3390/bios12030176 · Cited by 10
“With the labeling of the contrast agents, some literature studies report applying laser-induced acoustic measurement to assess the circulating metastatic melanoma cells in blood [25,26].”
Background
Metadata
- Authors
- Zharov, V. P., Galanzha, E. I., Shashkov, E. V., Khlebtsov, N. G., & Tuchin, V. V.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2006-11-22
- Volume
- 31
- Issue
- 24
- Pages
- 3623
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2024391597
- Cited by
- 229
- References
- 0
- FWCI
- 9.02
- Type
- journal article
- Language
- en
- Open access
- closed
- Licence
- doi.org/10.1364/OA_License_v1#VOR (vor)
- opg.optica.org/policies/opg-tdm-policy.json (tdm)
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: In vivo photoacoustic flow cytometry for monitoring of circulating single cancer cells and contrast agents. https://app.cochat.ai/papers/10.1364/ol.31.003623
- The paper
- Zharov, V. P., Galanzha, E. I., Shashkov, E. V., Khlebtsov, N. G., & Tuchin, V. V. (2006). In vivo photoacoustic flow cytometry for monitoring of circulating single cancer cells and contrast agents. Optics Letters. https://doi.org/10.1364/ol.31.003623
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.