The DOI matches its Crossref record.
Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM)
Open accessAbstract
Multidirectional selective plane illumination microscopy (mSPIM) reduces absorption and scattering artifacts and provides an evenly illuminated focal plane. mSPIM solves two common problems in light-sheet-based imaging techniques: The shadowing in the excitation path due to absorption in the specimen is eliminated by pivoting the light sheet; the spread of the light sheet by scattering in the sample is compensated by illuminating the sample consecutively from opposing directions. The resulting two images are computationally fused yielding a superior image. The effective light sheet is thinner, and the axial resolution is increased by square root 2 over single-directional SPIM. The multidirectional illumination proves essential in biological specimens such as millimeter-sized embryos. The performance of mSPIM is demonstrated by the imaging of live zebrafish embryos.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Going deeper than microscopy: the optical imaging frontier in biology
Ntziachristos, V. (2010) · Nature Methods · doi:10.1038/nmeth.1483 · Cited by 1,896
Selective plane illumination microscopy techniques in developmental biology
Huisken, J., & Stainier, D. Y. R. (2009) · Development · doi:10.1242/dev.022426 · Cited by 608
Self-citationA genome-wide resource for the analysis of protein localisation in Drosophila
Sarov, M., Barz, C., Jambor, H., Hein, M. Y., Schmied, C., Suchold, D., Stender, B., Janosch, S., KJ, V. V., Krishnan, R., et al. (2016) · eLife · doi:10.7554/elife.12068 · Cited by 359
Light-sheet microscopy: a tutorial
Olarte, O. E., Andilla, J., Gualda, E. J., & Loza-Alvarez, P. (2018) · Advances in Optics and Photonics · doi:10.1364/aop.10.000111 · Cited by 298
A versatile cortical pattern-forming circuit based on Rho, F-actin, Ect2, and RGA-3/4
Michaud, A., Leda, M., Swider, Z. T., Kim, S., He, J., Landino, J., Valley, J. R., Huisken, J., Goryachev, A. B., von Dassow, G., et al. (2022) · Journal of Cell Biology · doi:10.1083/jcb.202203017 · Cited by 59
Self-citation
Metadata
- Authors
- Huisken, J., & Stainier, D. Y. R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2007-08-27
- Volume
- 32
- Issue
- 17
- Pages
- 2608
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2110021835
- Cited by
- 424
- References
- 0
- FWCI
- 4.95
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM). https://app.cochat.ai/papers/10.1364/ol.32.002608
- The paper
- Huisken, J., & Stainier, D. Y. R. (2007). Even fluorescence excitation by multidirectional selective plane illumination microscopy (mSPIM). Optics Letters. https://doi.org/10.1364/ol.32.002608
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.