The DOI matches its Crossref record.
Stimulated emission depletion microscopy with a supercontinuum source and fluorescence lifetime imaging
Abstract
We demonstrate stimulated emission depletion (STED) microscopy implemented in a laser scanning confocal microscope using excitation light derived from supercontinuum generation in a microstructured optical fiber. Images with resolution improvement beyond the far-field diffraction limit in both the lateral and axial directions were acquired by scanning overlapped excitation and depletion beams in two dimensions using the flying spot scanner of a commercially available laser scanning confocal microscope. The spatial properties of the depletion beam were controlled holographically using a programmable spatial light modulator, which can rapidly change between different STED imaging modes and also compensate for aberrations in the optical path. STED fluorescence lifetime imaging microscopy is demonstrated through the use of time-correlated single photon counting.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Fluorescence lifetime imaging – techniques and applications
BECKER, W. (2012) · Journal of Microscopy · doi:10.1111/j.1365-2818.2012.03618.x · Cited by 890
Adaptive optical microscopy: the ongoing quest for a perfect image
Booth, M. J. (2014) · Light: Science & Applications · doi:10.1038/lsa.2014.46 · Cited by 645
Advanced Fluorescence Microscopy Techniques—FRAP, FLIP, FLAP, FRET and FLIM
Ishikawa-Ankerhold, H. C., Ankerhold, R., & Drummen, G. P. C. (2012) · Molecules · doi:10.3390/molecules17044047 · Cited by 557
Adaptive optical fluorescence microscopy
Ji, N. (2017) · Nature Methods · doi:10.1038/nmeth.4218 · Cited by 527
Sharper low-power STED nanoscopy by time gating
Vicidomini, G., Moneron, G., Han, K. Y., Westphal, V., Ta, H., Reuss, M., Engelhardt, J., Eggeling, C., & Hell, S. W. (2011) · Nature Methods · doi:10.1038/nmeth.1624 · Cited by 423
Stimulated Emission Depletion Microscopy
Blom, H., & Widengren, J. (2017) · Chemical Reviews · doi:10.1021/acs.chemrev.6b00653 · Cited by 339
The 2015 super-resolution microscopy roadmap
Hell, S. W., Sahl, S. J., Bates, M., Zhuang, X., Heintzmann, R., Booth, M. J., Bewersdorf, J., Shtengel, G., Hess, H., Tinnefeld, P., et al. (2015) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/48/44/443001 · Cited by 325
Adaptive optics enables 3D STED microscopy in aberrating specimens
Gould, T. J., Burke, D., Bewersdorf, J., & Booth, M. J. (2012) · Optics Express · doi:10.1364/oe.20.020998 · Cited by 315
Fluorescence lifetime imaging (FLIM): Basic concepts and some recent developments
Suhling, K., Hirvonen, L. M., Levitt, J. A., Chung, P.-H., Tregidgo, C., Le Marois, A., Rusakov, D. A., Zheng, K., Ameer-Beg, S., Poland, S., et al. (2015) · Medical Photonics · doi:10.1016/j.medpho.2014.12.001 · Cited by 313
Coaligned Dual-Channel STED Nanoscopy and Molecular Diffusion Analysis at 20 nm Resolution
Göttfert, F., Wurm, C. A., Mueller, V., Berning, S., Cordes, V. C., Honigmann, A., & Hell, S. W. (2013) · Biophysical Journal · doi:10.1016/j.bpj.2013.05.029 · Cited by 298
STED microscopy with a supercontinuum laser source
Wildanger, D., Rittweger, E., Kastrup, L., & Hell, S. W. (2008) · Optics Express · doi:10.1364/oe.16.009614 · Cited by 277
Fluorescence lifetime imaging microscopy in life sciences
Borst, J. W., & Visser, A. J. W. G. (2010) · Measurement Science and Technology · doi:10.1088/0957-0233/21/10/102002 · Cited by 168
Metadata
- Authors
- Auksorius, E., Boruah, B. R., Dunsby, C., Lanigan, P. M. P., Kennedy, G., Neil, M. A. A., & French, P. M. W.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2008-01-08
- Volume
- 33
- Issue
- 2
- Pages
- 113
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2086088902
- Cited by
- 190
- References
- 0
- FWCI
- 5.54
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.