Parallel confocal detection of single molecules in real time
The DOI matches its Crossref record.
Abstract
The confocal detection principle is extended to a highly parallel optical system that continuously analyzes thousands of concurrent sample locations. This is achieved through the use of a holographic laser illumination multiplexer combined with a confocal pinhole array before a prism dispersive element used to provide spectroscopic information from each confocal volume. The system is demonstrated to detect and identify single fluorescent molecules from each of several thousand independent confocal volumes in real time.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Next-generation DNA sequencing
Shendure, J., & Ji, H. (2008) · Nature Biotechnology · doi:10.1038/nbt1486 · Cited by 4,509
Accurate whole human genome sequencing using reversible terminator chemistry
Bentley, D. R., Balasubramanian, S., Swerdlow, H. P., Smith, G. P., Milton, J., Brown, C. G., Hall, K. P., Evers, D. J., Barnes, C. L., Bignell, H. R., et al. (2008) · Nature · doi:10.1038/nature07517 · Cited by 3,684
Self-citationReal-Time DNA Sequencing from Single Polymerase Molecules
Eid, J., Fehr, A., Gray, J., Luong, K., Lyle, J., Otto, G., Peluso, P., Rank, D., Baybayan, P., Bettman, B., et al. (2009) · Science · doi:10.1126/science.1162986 · Cited by 3,732
“highly parallel optical system that is capable of continuously analyzing thousands of concurrent sample locations (Lundquist et al., 2008) (Fig.”
BackgroundMethodSelf-citationDirect detection of DNA methylation during single-molecule, real-time sequencing
Flusberg, B. A., Webster, D. R., Lee, J. H., Travers, K. J., Olivares, E. C., Clark, T. A., Korlach, J., & Turner, S. W. (2010) · Nature Methods · doi:10.1038/nmeth.1459 · Cited by 1,460
Next generation sequencing technology: Advances and applications
Buermans, H. P. J., & den Dunnen, J. T. (2014) · Biochimica et Biophysica Acta (BBA) - Molecular Basis of Disease · doi:10.1016/j.bbadis.2014.06.015 · Cited by 752
Next generation sequencing and its applications in forensic genetics
Børsting, C., & Morling, N. (2015) · Forensic Science International: Genetics · doi:10.1016/j.fsigen.2015.02.002 · Cited by 460
“Soon after, the PacBio platform (Pacific Biosciences(1)) was launched [39,40] and recently, a beta-version of the MinION sequencer (Oxford Nanopore) was released for testing by members of the MinION access program.”
MethodLandscape of Next-Generation Sequencing Technologies
Niedringhaus, T. P., Milanova, D., Kerby, M. B., Snyder, M. P., & Barron, A. E. (2011) · Analytical Chemistry · doi:10.1021/ac2010857 · Cited by 378
Real-time tRNA transit on single translating ribosomes at codon resolution
Uemura, S., Aitken, C. E., Korlach, J., Flusberg, B. A., Turner, S. W., & Puglisi, J. D. (2010) · Nature · doi:10.1038/nature08925 · Cited by 351
Self-citationA practical guide to the oral microbiome and its relation to health and disease
Krishnan, K., Chen, T., & Paster, B. (2017) · Oral Diseases · doi:10.1111/odi.12509 · Cited by 347
“This instrument is sensitive enough to detect a single fluorescently labeled nucleotide (Korlach et al., 2008, Levene et al., 2003, Lundquist et al., 2008) and is purportedly able to generate ~10,000 bp reads.”
BackgroundReal-Time DNA Sequencing from Single Polymerase Molecules
Korlach, J., Bjornson, K. P., Chaudhuri, B. P., Cicero, R. L., Flusberg, B. A., Gray, J. J., Holden, D., Saxena, R., Wegener, J., & Turner, S. W. (2010) · Methods in Enzymology · doi:10.1016/s0076-6879(10)72001-2 · Cited by 313
Self-citationThe challenges of sequencing by synthesis
Fuller, C. W., Middendorf, L. R., Benner, S. A., Church, G. M., Harris, T., Huang, X., Jovanovich, S. B., Nelson, J. R., Schloss, J. A., Schwartz, D. C., et al. (2009) · Nature Biotechnology · doi:10.1038/nbt.1585 · Cited by 280
DNA manipulation, sorting, and mapping in nanofluidic systems
Levy, S. L., & Craighead, H. G. (2010) · Chemical Society Reviews · doi:10.1039/b820266b · Cited by 178
Vilfan, I. D., Tsai, Y.-C., Clark, T. A., Wegener, J., Dai, Q., Yi, C., Pan, T., Turner, S. W., & Korlach, J. (2013) · Journal of Nanobiotechnology · doi:10.1186/1477-3155-11-8 · Cited by 159
“Singlemolecule experiments were performed using arrays of 3,000 ZMWs monitored simultaneously, with excitation laser lines as described previously [3,28].”
MethodSelf-citation
Metadata
- Authors
- Lundquist, P. M., Zhong, C. F., Zhao, P., Tomaney, A. B., Peluso, P. S., Dixon, J., Bettman, B., Lacroix, Y., Kwo, D. P., McCullough, E., Maxham, M., Hester, K., McNitt, P., Grey, D. M., Henriquez, C., Foquet, M., Turner, S. W., & Zaccarin, D.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2008-04-30
- Volume
- 33
- Issue
- 9
- Pages
- 1026
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2092055233
- Cited by
- 102
- References
- 0
- FWCI
- 6.06
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.