The DOI matches its Crossref record.
Reflective terahertz imaging of porcine skin burns
Abstract
A reflective pulsed terahertz imaging system based on direct detection was developed and used to obtain high-resolution images of a porcine skin specimen with superficial partial-thickness (second-degree) burns. Images were also obtained of the sample through ten layers of dry medical (cotton) gauze with minimal image degradation. The burned and unburned regions of skin had large differences in terahertz reflectivity, displaying clear delineation [20 dB signal-to-noise ratio (SNR) difference signal] between both regions in the images. The terahertz images also exhibited a "halo" surrounding the burn areas that may correlate to the extent of burn injury. The system operated at a center frequency of 500 GHz with 125 GHz of 3 dB bandwidth and used whiskbroom scanning to generate images with a spatial resolution of 1.5 mm. Each pixel was acquired with a 16 ms integration time, resulting in a 40 dB postdetection SNR. The simplicity and high SNR of the reflective terahertz system are promising steps toward real-time terahertz medical imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Review of terahertz photoconductive antenna technology
Burford, N. M., & El-Shenawee, M. O. (2017) · Optical Engineering · doi:10.1117/1.oe.56.1.010901 · Cited by 453
THz Medical Imaging: in vivo Hydration Sensing
Taylor, Z. D., Singh, R. S., Bennett, D. B., Tewari, P., Kealey, C. P., Bajwa, N., Culjat, M. O., Stojadinovic, A., Lee, H., Hubschman, J.-P., et al. (2011) · IEEE Transactions on Terahertz Science and Technology · doi:10.1109/tthz.2011.2159551 · Cited by 362
Self-citationInvited Review Article: Current State of Research on Biological Effects of Terahertz Radiation
Wilmink, G. J., & Grundt, J. E. (2011) · Journal of Infrared, Millimeter, and Terahertz Waves · doi:10.1007/s10762-011-9794-5 · Cited by 314
Wilmink, G. J., Ibey, B. L., Rivest, B. D., Grundt, J. E., Roach, W. P., Tongue, T. D., Schulkin, B. J., Laman, N., Peralta, X. G., Roth, C. C., et al. (2011) · Journal of Biomedical Optics · doi:10.1117/1.3570648 · Cited by 109
Accuracy of sample material parameters reconstruction using terahertz pulsed spectroscopy
Zaytsev, K. I., Gavdush, A. A., Karasik, V. E., Alekhnovich, V. I., Nosov, P. A., Lazarev, V. A., Reshetov, I. V., & Yurchenko, S. O. (2014) · Journal of Applied Physics · doi:10.1063/1.4876324 · Cited by 53
Metadata
- Authors
- Taylor, Z. D., Singh, R. S., Culjat, M. O., Suen, J. Y., Grundfest, W. S., Lee, H., & Brown, E. R.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2008-05-30
- Volume
- 33
- Issue
- 11
- Pages
- 1258
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2075373739
- Cited by
- 176
- References
- 0
- FWCI
- 8.67
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Reflective terahertz imaging of porcine skin burns. https://app.cochat.ai/papers/10.1364/ol.33.001258
- The paper
- Taylor, Z. D., Singh, R. S., Culjat, M. O., Suen, J. Y., Grundfest, W. S., Lee, H., & Brown, E. R. (2008). Reflective terahertz imaging of porcine skin burns. Optics Letters. https://doi.org/10.1364/ol.33.001258
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.