The DOI matches its Crossref record; 4 of the 4 references it cites were found in a registry or an index.
Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography
Open accessAbstract
We demonstrate the depth-resolved and detailed ocular perfusion maps within retina and choroid can be obtained from an ultrahigh sensitive optical microangiography (OMAG). As opposed to the conventional OMAG, we apply the OMAG algorithm along the slow scanning axis to achieve the ultrahigh sensitive imaging to the slow flows within capillaries. We use an 840 nm system operating at an imaging rate of 400 frames/s that requires 3 s to complete one 3D scan of approximately 3 x 3 mm(2) area on retina. We show the superior imaging performance of OMAG to provide functional images of capillary level microcirculation at different land-marked depths within retina and choroid that correlate well with the standard retinal pathology.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Optical coherence tomography - principles and applications
Fercher, A. F., Drexler, W., Hitzenberger, C. K., & Lasser, T. (2003) · Reports on Progress in Physics · doi:10.1088/0034-4885/66/2/204 · Cited by 1,866
Theory, developments and applications of optical coherence tomography
Tomlins, P. H., & Wang, R. K. (2005) · Journal of Physics D: Applied Physics · doi:10.1088/0022-3727/38/15/002 · Cited by 631
Self-citationThree dimensional optical angiography
Wang, R. K., Jacques, S. L., Ma, Z., Hurst, S., Hanson, S. R., & Gruber, A. (2007) · Optics Express · doi:10.1364/oe.15.004083 · Cited by 627
Self-citationWang, R. K., & Hurst, S. (2007) · Optics Express · doi:10.1364/oe.15.011402 · Cited by 124
Self-citation
Cited by
Split-spectrum amplitude-decorrelation angiography with optical coherence tomography
Jia, Y., Tan, O., Tokayer, J., Potsaid, B., Wang, Y., Liu, J. J., Kraus, M. F., Subhash, H., Fujimoto, J. G., Hornegger, J., et al. (2012) · Optics Express · doi:10.1364/oe.20.004710 · Cited by 1,841
Kashani, A. H., Chen, C.-L., Gahm, J. K., Zheng, F., Richter, G. M., Rosenfeld, P. J., Shi, Y., & Wang, R. K. (2017) · Progress in Retinal and Eye Research · doi:10.1016/j.preteyeres.2017.07.002 · Cited by 1,006
Self-citationRoisman, L., Zhang, Q., Wang, R. K., Gregori, G., Zhang, A., Chen, C.-L., Durbin, M. K., An, L., Stetson, P. F., Robbins, G., et al. (2016) · Ophthalmology · doi:10.1016/j.ophtha.2016.01.044 · Cited by 261
Self-citationOcular Blood Flow and Influencing Factors for Glaucoma
Nakazawa, T. (2016) · Asia-Pacific Journal of Ophthalmology · doi:10.1097/apo.0000000000000183 · Cited by 129
Metadata
- Authors
- Wang, R. K., An, L., Francis, P., & Wilson, D. J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2010-04-30
- Volume
- 35
- Issue
- 9
- Pages
- 1467
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1970915153
- Cited by
- 355
- References
- 4
- FWCI
- 14.22
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography. https://app.cochat.ai/papers/10.1364/ol.35.001467
- The paper
- Wang, R. K., An, L., Francis, P., & Wilson, D. J. (2010). Depth-resolved imaging of capillary networks in retina and choroid using ultrahigh sensitive optical microangiography. Optics Letters. https://doi.org/10.1364/ol.35.001467
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.