The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Diffraction phase microscopy with white light
Abstract
We present white light diffraction phase microscopy (wDPM) as a quantitative phase imaging method that combines the single shot measurement benefit associated with off-axis methods, high temporal phase stability associated with common path geometries, and high spatial phase sensitivity due to the white light illumination. We propose a spatiotemporal filtering method that pushes the limit of the pathlength sensitivity to the subangstrom level at practical spatial and temporal bandwidths. We illustrate the utility of wDPM with measurements on red blood cell morphology and HeLa cell growth over 18 hours.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Park, Y., Diez-Silva, M., Popescu, G., Lykotrafitis, G., Choi, W., Feld, M. S., & Suresh, S. (2008) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.0806100105 · Cited by 689
Self-citationFourier phase microscopy for investigation of biological structures and dynamics
Popescu, G., DeFlores, L. P., Vaughan, J. C., Badizadegan, K., Iwai, H., Dasari, R. R., & Feld, M. S. (2004) · Optics Letters · doi:10.1364/ol.29.002503 · Cited by 450
Self-citationInterference Microscopy and Mass Determination
BARER, R. (1952) · Nature · doi:10.1038/169366b0 · Cited by 433
Optical measurement of cycle-dependent cell growth
Mir, M., Wang, Z., Shen, Z., Bednarz, M., Bashir, R., Golding, I., Prasanth, S. G., & Popescu, G. (2011) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1100506108 · Cited by 409
Self-citationInterference Microscopy and Mass Determination
DAVIES, H. G., & WILKINS, M. H. F. (1952) · Nature · doi:10.1038/169541a0 · Cited by 209
Quantitative phase imaging with broadband fields
Wang, Z., & Popescu, G. (2010) · Applied Physics Letters · doi:10.1063/1.3304787 · Cited by 37
Self-citation
Cited by
Diffraction phase microscopy: principles and applications in materials and life sciences
Bhaduri, B., Edwards, C., Pham, H., Zhou, R., Nguyen, T. H., Goddard, L. L., & Popescu, G. (2014) · Advances in Optics and Photonics · doi:10.1364/aop.6.000057 · Cited by 425
Self-citationLive-cell mass profiling: an emerging approach in quantitative biophysics
Zangle, T. A., & Teitell, M. A. (2014) · Nature Methods · doi:10.1038/nmeth.3175 · Cited by 260
Gradient light interference microscopy for 3D imaging of unlabeled specimens
Nguyen, T. H., Kandel, M. E., Rubessa, M., Wheeler, M. B., & Popescu, G. (2017) · Nature Communications · doi:10.1038/s41467-017-00190-7 · Cited by 259
Self-citationPractical application of microsphere samples for benchmarking a quantitative phase imaging system
Kwee, E., Peterson, A., Halter, M., & Elliott, J. (2021) · Cytometry Part A · doi:10.1002/cyto.a.24291 · Cited by 9
Metadata
- Authors
- Bhaduri, B., Pham, H., Mir, M., & Popescu, G.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2012-03-14
- Volume
- 37
- Issue
- 6
- Pages
- 1094
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W4231392132
- Cited by
- 304
- References
- 6
- FWCI
- 13.46
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Diffraction phase microscopy with white light. https://app.cochat.ai/papers/10.1364/ol.37.001094
- The paper
- Bhaduri, B., Pham, H., Mir, M., & Popescu, G. (2012). Diffraction phase microscopy with white light. Optics Letters. https://doi.org/10.1364/ol.37.001094
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.