Mid-infrared dual-comb spectroscopy with an optical parametric oscillator
The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
We present the first implementation of mid-infrared dual-comb spectroscopy with an optical parametric oscillator. Methane absorption spectroscopy was demonstrated with a resolution of 0.2 cm(-1) (5 GHz) at an acquisition time of ~10.4 ms over a spectral coverage at 2900-3050 cm(-1). The average power from each individual mid-infrared comb line was ~1 μW, representing a power level much greater than typical difference-frequency-generation sources. Mid-infrared dual-comb spectroscopy opens up unique opportunities to perform broadband spectroscopic measurements with high resolution, high requisition rate, and high detection sensitivity.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Cited by
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
Adaptive real-time dual-comb spectroscopy
Ideguchi, T., Poisson, A., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2014) · Nature Communications · doi:10.1038/ncomms4375 · Cited by 434
Silicon-chip-based mid-infrared dual-comb spectroscopy
Yu, M., Okawachi, Y., Griffith, A. G., Picqué, N., Lipson, M., & Gaeta, A. L. (2018) · Nature Communications · doi:10.1038/s41467-018-04350-1 · Cited by 416
Frequency-comb-based remote sensing of greenhouse gases over kilometer air paths
Rieker, G. B., Giorgetta, F. R., Swann, W. C., Kofler, J., Zolot, A. M., Sinclair, L. C., Baumann, E., Cromer, C., Petron, G., Sweeney, C., et al. (2014) · Optica · doi:10.1364/optica.1.000290 · Cited by 409
High-coherence mid-infrared dual-comb spectroscopy spanning 2.6 to 5.2 μm
Ycas, G., Giorgetta, F. R., Baumann, E., Coddington, I., Herman, D., Diddams, S. A., & Newbury, N. R. (2018) · Nature Photonics · doi:10.1038/s41566-018-0114-7 · Cited by 349
Metadata
- Authors
- Zhang, Z., Gardiner, T., & Reid, D. T.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2013-08-14
- Volume
- 38
- Issue
- 16
- Pages
- 3148
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W2111509177
- Cited by
- 120
- References
- 1
- FWCI
- 6.14
- Type
- journal article
- Language
- en
- Open access
- closed
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Mid-infrared dual-comb spectroscopy with an optical parametric oscillator. https://app.cochat.ai/papers/10.1364/ol.38.003148
- The paper
- Zhang, Z., Gardiner, T., & Reid, D. T. (2013). Mid-infrared dual-comb spectroscopy with an optical parametric oscillator. Optics Letters. https://doi.org/10.1364/ol.38.003148
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.