The DOI matches its Crossref record; 2 of the 2 references it cites were found in a registry or an index.
High-flux table-top soft x-ray source driven by sub-2-cycle, CEP stable, 185-μm 1-kHz pulses for carbon K-edge spectroscopy
Open accessAbstract
We report on the first table-top high-flux source of coherent soft x-ray radiation up to 400 eV, operating at 1 kHz. This source covers the carbon K-edge with a beam brilliance of (4.3±1.2)×10(15) photons/s/mm(2)/strad/10% bandwidth and a photon flux of (1.85±0.12)×10(7) photons/s/1% bandwidth. We use this source to demonstrate table-top x-ray near-edge fine-structure spectroscopy at the carbon K-edge of a polyimide foil and retrieve the specific absorption features corresponding to the binding orbitals of the carbon atoms in the foil.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bright Coherent Ultrahigh Harmonics in the keV X-ray Regime from Mid-Infrared Femtosecond Lasers
Popmintchev, T., Chen, M.-C., Popmintchev, D., Arpin, P., Brown, S., Ališauskas, S., Andriukaitis, G., Balčiunas, T., Mücke, O. D., Pugzlys, A., et al. (2012) · Science · doi:10.1126/science.1218497 · Cited by 1,830
Ishii, N., Kaneshima, K., Kitano, K., Kanai, T., Watanabe, S., & Itatani, J. (2014) · Nature Communications · doi:10.1038/ncomms4331 · Cited by 228
Cited by
Streaking of 43-attosecond soft-X-ray pulses generated by a passively CEP-stable mid-infrared driver
Gaumnitz, T., Jain, A., Pertot, Y., Huppert, M., Jordan, I., Ardana-Lamas, F., & Wörner, H. J. (2017) · Optics Express · doi:10.1364/oe.25.027506 · Cited by 568
Time-resolved x-ray absorption spectroscopy with a water window high-harmonic source
Pertot, Y., Schmidt, C., Matthews, M., Chauvet, A., Huppert, M., Svoboda, V., von Conta, A., Tehlar, A., Baykusheva, D., Wolf, J.-P., et al. (2017) · Science · doi:10.1126/science.aah6114 · Cited by 383
High-power sub-two-cycle mid-infrared pulses at 100 MHz repetition rate
Pupeza, I., Sánchez, D., Zhang, J., Lilienfein, N., Seidel, M., Karpowicz, N., Paasch-Colberg, T., Znakovskaya, I., Pescher, M., Schweinberger, W., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.179 · Cited by 304
Self-citation0.5-keV Soft X-ray attosecond continua
Teichmann, S. M., Silva, F., Cousin, S. L., Hemmer, M., & Biegert, J. (2016) · Nature Communications · doi:10.1038/ncomms11493 · Cited by 265
Self-citationStrong-Field Physics with Mid-IR Fields
Wolter, B., Pullen, M. G., Baudisch, M., Sclafani, M., Hemmer, M., Senftleben, A., Schröter, C. D., Ullrich, J., Moshammer, R., & Biegert, J. (2015) · Physical Review X · doi:10.1103/physrevx.5.021034 · Cited by 259
Self-citation
Metadata
- Authors
- Cousin, S. L., Silva, F., Teichmann, S., Hemmer, M., Buades, B., & Biegert, J.
- Venue
- Optics Letters
- Publisher
- Optica Publishing Group
- Published
- 2014-09-11
- Volume
- 39
- Issue
- 18
- Pages
- 5383
- ISSN
- 0146-9592 (ISSN-L)
- 1539-4794
- OpenAlex
- W1979462770
- Cited by
- 179
- References
- 2
- FWCI
- 10.48
- Type
- journal article
- Language
- en
- Open access
- green
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: High-flux table-top soft x-ray source driven by sub-2-cycle, CEP stable, 185-μm 1-kHz pulses for carbon K-edge spectroscopy. https://app.cochat.ai/papers/10.1364/ol.39.005383
- The paper
- Cousin, S. L., Silva, F., Teichmann, S., Hemmer, M., Buades, B., & Biegert, J. (2014). High-flux table-top soft x-ray source driven by sub-2-cycle, CEP stable, 185-μm 1-kHz pulses for carbon K-edge spectroscopy. Optics Letters. https://doi.org/10.1364/ol.39.005383
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.