The DOI matches its Crossref record.
The use of Gauss-Laguerre vector beams in STED microscopy
Open accessAbstract
This paper examines the use of Gauss-Laguerre beams in STED microscopy. These types of beams are shown to have beneficial properties that can be utilised to generate stable, high quality STED beams resulting in an aberration-resilient generation volume. In this paper we obtain general expressions for Gauss-Laguerre beams being focused through a stratified medium and describe their optimization for STED microscopy purposes. Our results show that the circularly polarised, lowest order "dark" beam is the most beneficial for STED purposes.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cited by
Optical ferris wheel for ultracold atoms
Franke-Arnold, S., Leach, J., Padgett, M. J., Lembessis, V. E., Ellinas, D., Wright, A. J., Girkin, J. M., Öhberg, P., & Arnold, A. S. (2007) · Optics Express · doi:10.1364/oe.15.008619 · Cited by 346
Bokor, N., Iketaki, Y., Watanabe, T., & Fujii, M. (2005) · Optics Express · doi:10.1364/opex.13.010440 · Cited by 102
Conformal frequency conversion for arbitrary vectorial structured light
Wu, H.-J., Yu, B.-S., Zhu, Z.-H., Gao, W., Ding, D.-S., Zhou, Z.-Y., Hu, X.-P., Rosales-Guzmán, C., Shen, Y., & Shi, B.-S. (2022) · Optica · doi:10.1364/optica.444685 · Cited by 84
Delaney, S., Sánchez-López, M. M., Moreno, I., & Davis, J. A. (2017) · Applied Optics · doi:10.1364/ao.56.000596 · Cited by 42
Metadata
- Authors
- Török, P., & Munro, P. R. T.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2004-07-26
- Volume
- 12
- Issue
- 15
- Pages
- 3605
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2152602586
- Cited by
- 269
- References
- 0
- FWCI
- 3.89
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: The use of Gauss-Laguerre vector beams in STED microscopy. https://app.cochat.ai/papers/10.1364/opex.12.003605
- The paper
- Török, P., & Munro, P. R. T. (2004). The use of Gauss-Laguerre vector beams in STED microscopy. Optics Express. https://doi.org/10.1364/opex.12.003605
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.