Student or educator? Sign up with your school email and get 6 months of Pro free.
Cited by 361

The DOI matches its Crossref record.

Superresolution by localization of quantum dots using blinking statistics

Open access
Lidke, Keith A., Rieger, Bernd, Jovin, Thomas M., Heintzmann, Rainer·2005·Optics Express

Abstract

In microscopy, single fluorescence point sources can be localized with a precision several times greater than the resolution limit of the microscope. We show that the intermittent fluorescence or 'blinking' of quantum dots can analyzed by an Independent Component Analysis so as to identify the light emitted by each individual nanoparticle, localize it precisely, and thereby resolve groups of closely spaced (< lambda / 30) quantum dots. Both simulated and experimental data demonstrate that this technique is superior to localization based on Maximum Likelihood Estimation of the sum image under the assumption of point emitters. This technique has general application to any emitter with non-Gaussian temporal intensity distribution, including triplet state blinking. When applied to the labeling of structures, a high resolution "image" consisting of individually localized points may be reconstructed leading to the term "Pointillism".

Overview

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Integrity signals

Registry

Crossref · 10.1364/opex.13.007052

Cites

Statistics

Verification

Claims the paper makes

The claims and statistics of this paper haven’t been checked yet.

Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.

A few free checks a day · papers already verified open instantly · results are public

Self-check

Percentages, sums and reported differences re-computed from the paper’s own numbers.

The self-check needs the paper’s full text.

Citations

Cited by

See all 361

Metadata

Authors
Lidke, K. A., Rieger, B., Jovin, T. M., & Heintzmann, R.
Venue
Optics Express
Published
2005
Volume
13
Issue
18
Pages
7052
ISSN
1094-4087 (ISSN-L)
OpenAlex
W2015258075
Cited by
361
References
0
FWCI
8.07
Type
journal article
Language
en
Open access
gold

About these checks

Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.

Statistics and arithmetic are recomputed, not judged.

Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.

What counts as a claim ›How we measure confidence ›How we check this ›

Are you an author, or do you see a problem with this page? Request a review

How to cite

Cite CoChat for the checks on this page, and the paper for its own findings.

This page
CoChat. (2026). Citation check: Superresolution by localization of quantum dots using blinking statistics. https://app.cochat.ai/papers/10.1364/opex.13.007052
The paper
Lidke, K. A., Rieger, B., Jovin, T. M., & Heintzmann, R. (2005). Superresolution by localization of quantum dots using blinking statistics. Optics Express. https://doi.org/10.1364/opex.13.007052

Data sources

Bibliographic data: Semantic Scholar, OpenAlex, Crossref.

Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).

Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.