The DOI matches its Crossref record; 6 of the 6 references it cites were found in a registry or an index.
Superresolution by localization of quantum dots using blinking statistics
Open accessAbstract
In microscopy, single fluorescence point sources can be localized with a precision several times greater than the resolution limit of the microscope. We show that the intermittent fluorescence or 'blinking' of quantum dots can analyzed by an Independent Component Analysis so as to identify the light emitted by each individual nanoparticle, localize it precisely, and thereby resolve groups of closely spaced (< lambda / 30) quantum dots. Both simulated and experimental data demonstrate that this technique is superior to localization based on Maximum Likelihood Estimation of the sum image under the assumption of point emitters. This technique has general application to any emitter with non-Gaussian temporal intensity distribution, including triplet state blinking. When applied to the labeling of structures, a high resolution "image" consisting of individually localized points may be reconstructed leading to the term "Pointillism".
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Fast and robust fixed-point algorithms for independent component analysis
Hyvarinen, A. (1999) · IEEE Transactions on Neural Networks · doi:10.1109/72.761722 · Cited by 6,246
Blind signal separation: statistical principles
Cardoso, J.-F. (1998) · Proceedings of the IEEE · doi:10.1109/5.720250 · Cited by 1,885
Myosin V Walks Hand-Over-Hand: Single Fluorophore Imaging with 1.5-nm Localization
Yildiz, A., Forkey, J. N., McKinney, S. A., Ha, T., Goldman, Y. E., & Selvin, P. R. (2003) · Science · doi:10.1126/science.1084398 · Cited by 1,837
Quantum dot ligands provide new insights into erbB/HER receptor–mediated signal transduction
Lidke, D. S., Nagy, P., Heintzmann, R., Arndt-Jovin, D. J., Post, J. N., Grecco, H. E., Jares-Erijman, E. A., & Jovin, T. M. (2004) · Nature Biotechnology · doi:10.1038/nbt929 · Cited by 828
Self-citationNear-Complete Suppression of Quantum Dot Blinking in Ambient Conditions
Hohng, S., & Ha, T. (2004) · Journal of the American Chemical Society · doi:10.1021/ja039686w · Cited by 515
High-Resolution Colocalization of Single Dye Molecules by Fluorescence Lifetime Imaging Microscopy
Heilemann, M., Herten, D., Heintzmann, R., Cremer, C. G., Müller, C., Tinnefeld, P., Weston, K. D., Wolfrum, J., & Sauer, M. (2002) · Analytical Chemistry · doi:10.1021/ac025576g · Cited by 117
Self-citation
Cited by
Imaging Intracellular Fluorescent Proteins at Nanometer Resolution
Betzig, E., Patterson, G. H., Sougrat, R., Lindwasser, O. W., Olenych, S., Bonifacino, J. S., Davidson, M. W., Lippincott-Schwartz, J., & Hess, H. F. (2006) · Science · doi:10.1126/science.1127344 · Cited by 8,772
Sub-diffraction-limit imaging by stochastic optical reconstruction microscopy (STORM)
Rust, M. J., Bates, M., & Zhuang, X. (2006) · Nature Methods · doi:10.1038/nmeth929 · Cited by 8,078
Quantum dots versus organic dyes as fluorescent labels
Resch-Genger, U., Grabolle, M., Cavaliere-Jaricot, S., Nitschke, R., & Nann, T. (2008) · Nature Methods · doi:10.1038/nmeth.1248 · Cited by 3,833
Hell, S. W. (2007) · Science · doi:10.1126/science.1137395 · Cited by 2,967
“While extended molecular separation by spectral shifts is certainly interesting and may be eventually practical, the transition [111, 112] from single emitter localization to nanoscale imaging [43–45, 129] has thus not been facilitated by spectral separation, but by fluorescence switching.”
BackgroundSubdiffraction‐Resolution Fluorescence Imaging with Conventional Fluorescent Probes
Heilemann, M., van de Linde, S., Schüttpelz, M., Kasper, R., Seefeldt, B., Mukherjee, A., Tinnefeld, P., & Sauer, M. (2008) · Angewandte Chemie International Edition · doi:10.1002/anie.200802376 · Cited by 1,866
Metadata
- Authors
- Lidke, K. A., Rieger, B., Jovin, T. M., & Heintzmann, R.
- Venue
- Optics Express
- Publisher
- Optica Publishing Group
- Published
- 2005
- Volume
- 13
- Issue
- 18
- Pages
- 7052
- ISSN
- 1094-4087 (ISSN-L)
- OpenAlex
- W2015258075
- Cited by
- 361
- References
- 6
- FWCI
- 8.07
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.