The DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Tabletop nanometer extreme ultraviolet imaging in an extended reflection mode using coherent Fresnel ptychography
Open accessAbstract
We demonstrate the first (to our knowledge) general purpose full-field reflection-mode extreme ultraviolet (EUV) microscope based on coherent diffractive imaging. This microscope is capable of nanoscale amplitude and phase imaging of extended surfaces at an arbitrary angle of incidence in a noncontact, nondestructive manner. We use coherent light at 29.5 nm from high-harmonic upconversion to illuminate a surface, directly recording the scatter as the surface is scanned. Ptychographic reconstruction is then combined with tilted plane correction to obtain an image with amplitude and phase information. The image quality and detail from this diffraction-limited tabletop EUV microscope compares favorably with both scanning electron microscope and atomic force microscope images. The result is a general and completely extensible imaging technique that can provide a comprehensive and definitive characterization of how light at any wavelength scatters from a surface, with imminent feasibility of elemental imaging with
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Bright Coherent Ultrahigh Harmonics in the keV X-ray Regime from Mid-Infrared Femtosecond Lasers
Popmintchev, T., Chen, M.-C., Popmintchev, D., Arpin, P., Brown, S., Ališauskas, S., Andriukaitis, G., Balčiunas, T., Mücke, O. D., Pugzlys, A., et al. (2012) · Science · doi:10.1126/science.1218497 · Cited by 1,830
Self-citation
Cited by
Beyond crystallography: Diffractive imaging using coherent x-ray light sources
Miao, J., Ishikawa, T., Robinson, I. K., & Murnane, M. M. (2015) · Science · doi:10.1126/science.aaa1394 · Cited by 808
Self-citationFurther improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
Bright circularly polarized soft X-ray high harmonics for X-ray magnetic circular dichroism
Fan, T., Grychtol, P., Knut, R., Hernández-García, C., Hickstein, D. D., Zusin, D., Gentry, C., Dollar, F. J., Mancuso, C. A., Hogle, C. W., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1519666112 · Cited by 298
Self-citationNon-collinear generation of angularly isolated circularly polarized high harmonics
Hickstein, D. D., Dollar, F. J., Grychtol, P., Ellis, J. L., Knut, R., Hernández-García, C., Zusin, D., Gentry, C., Shaw, J. M., Fan, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.181 · Cited by 282
Self-citation
Metadata
- Authors
- Seaberg, M. D., Zhang, B., Gardner, D. F., Shanblatt, E. R., Murnane, M. M., Kapteyn, H. C., & Adams, D. E.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2014-07-22
- Volume
- 1
- Issue
- 1
- Pages
- 39
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2112146488
- Cited by
- 197
- References
- 1
- FWCI
- 17.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Tabletop nanometer extreme ultraviolet imaging in an extended reflection mode using coherent Fresnel ptychography. https://app.cochat.ai/papers/10.1364/optica.1.000039
- The paper
- Seaberg, M. D., Zhang, B., Gardner, D. F., Shanblatt, E. R., Murnane, M. M., Kapteyn, H. C., & Adams, D. E. (2014). Tabletop nanometer extreme ultraviolet imaging in an extended reflection mode using coherent Fresnel ptychography. Optica. https://doi.org/10.1364/optica.1.000039
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.