Tabletop nanometer extreme ultraviolet imaging in an extended reflection mode using coherent Fresnel ptychography
Open accessThe DOI matches its Crossref record; 18 of the 18 references it cites were found in a registry or an index.
Abstract
We demonstrate the first (to our knowledge) general purpose full-field reflection-mode extreme ultraviolet (EUV) microscope based on coherent diffractive imaging. This microscope is capable of nanoscale amplitude and phase imaging of extended surfaces at an arbitrary angle of incidence in a noncontact, nondestructive manner. We use coherent light at 29.5 nm from high-harmonic upconversion to illuminate a surface, directly recording the scatter as the surface is scanned. Ptychographic reconstruction is then combined with tilted plane correction to obtain an image with amplitude and phase information. The image quality and detail from this diffraction-limited tabletop EUV microscope compares favorably with both scanning electron microscope and atomic force microscope images. The result is a general and completely extensible imaging technique that can provide a comprehensive and definitive characterization of how light at any wavelength scatters from a surface, with imminent feasibility of elemental imaging with
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Henke, B. L., Gullikson, E. M., & Davis, J. C. (1993) · Atomic Data and Nuclear Data Tables · doi:10.1006/adnd.1993.1013 · Cited by 6,285 · cited 2×
“[22] Henke, B.”
Miao, J., Charalambous, P., Kirz, J., & Sayre, D. (1999) · Nature · doi:10.1038/22498 · Cited by 1,976
Bright Coherent Ultrahigh Harmonics in the keV X-ray Regime from Mid-Infrared Femtosecond Lasers
Popmintchev, T., Chen, M.-C., Popmintchev, D., Arpin, P., Brown, S., Ališauskas, S., Andriukaitis, G., Balčiunas, T., Mücke, O. D., Pugzlys, A., et al. (2012) · Science · doi:10.1126/science.1218497 · Cited by 1,830 · cited 1×
“Finally, because we use a tabletop high harmonic generation (HHG) 30 nm source [14], in the future it will be possible to image energy, charge and spin transport with nm spatial and fs temporal resolution on nanostructured surfaces or buried interfaces, which is a grand challenge in nanoscience and nanotechnology [15,…”
MethodSelf-citationAn improved ptychographical phase retrieval algorithm for diffractive imaging
Maiden, A. M., & Rodenburg, J. M. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2009.05.012 · Cited by 1,496 · cited 4×
“However, we find that for ptychographic grids of 3 × 3 and larger with sufficient overlap between adjacent probe positions (60-70% area overlap [12]), the algorithm converges to a consistent result for the probe provided that the phase curvature of the starting guess differs by no more than 50% of the actual phase cur…”
BackgroundMethodInfluentialProbe retrieval in ptychographic coherent diffractive imaging
Thibault, P., Dierolf, M., Bunk, O., Menzel, A., & Pfeiffer, F. (2009) · Ultramicroscopy · doi:10.1016/j.ultramic.2008.12.011 · Cited by 717 · cited 2×
“The positions were randomized by up to 1 μm in order to prevent periodic artifacts from occurring in the ptychographic reconstruction[18].”
BackgroundMethodGeneration of Spatially Coherent Light at Extreme Ultraviolet Wavelengths
Bartels, R. A., Paul, A., Green, H., Kapteyn, H. C., Murnane, M. M., Backus, S., Christov, I. P., Liu, Y., Attwood, D., & Jacobsen, C. (2002) · Science · doi:10.1126/science.1071718 · Cited by 413 · cited 1×
“Bright harmonics of the fundamental laser are produced near a center wavelength of 29 nm (27th harmonic) since the high harmonic generation process is well phase-matched [17], ensuring strong coherent signal growth and high spatial coherence.”
BackgroundSelf-citationTranslation position determination in ptychographic coherent diffraction imaging
Zhang, F., Peterson, I., Vila‐Comamala, J., et al. (2013) · Optics Express · doi:10.1364/oe.21.013592 · Cited by 324 · cited 2×
“The image was reconstructed using the ePIE, along with the sub-pixel position determination method [20, 21].”
MethodUltrafast Three-Dimensional Imaging of Lattice Dynamics in Individual Gold Nanocrystals
Clark, J. N., Beitra, L., Xiong, G., Higginbotham, A., Fritz, D. M., Lemke, H. T., Zhu, D., Chollet, M., Williams, G. J., Messerschmidt, M., et al. (2013) · Science · doi:10.1126/science.1236034 · Cited by 316 · cited 2×
“CDI has already been used to study a variety of biological and materials systems [3–7].”
MethodQuantitative 3D imaging of whole, unstained cells by using X-ray diffraction microscopy
Jiang, H., Song, C., Chen, C., Xu, R., Raines, K. S., Fahimian, B., Lu, C.-H., Lee, T.-K., Nakashima, A., Urano, J., et al. (2010) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1000156107 · Cited by 282 · cited 1×
“CDI has already been used to study a variety of biological and materials systems [3–7].”
MethodSuperresolution imaging via ptychography
Maiden, A. M., Humphry, M. J., Zhang, F., & Rodenburg, J. M. (2011) · Journal of the Optical Society of America A · doi:10.1364/josaa.28.000604 · Cited by 256 · cited 2×
“The image was reconstructed using the ePIE, along with the sub-pixel position determination method [20, 21].”
Method
Cited by
Beyond crystallography: Diffractive imaging using coherent x-ray light sources
Miao, J., Ishikawa, T., Robinson, I. K., & Murnane, M. M. (2015) · Science · doi:10.1126/science.aaa1394 · Cited by 808
Self-citationFurther improvements to the ptychographical iterative engine
Maiden, A., Johnson, D., & Li, P. (2017) · Optica · doi:10.1364/optica.4.000736 · Cited by 452
Bright circularly polarized soft X-ray high harmonics for X-ray magnetic circular dichroism
Fan, T., Grychtol, P., Knut, R., Hernández-García, C., Hickstein, D. D., Zusin, D., Gentry, C., Dollar, F. J., Mancuso, C. A., Hogle, C. W., et al. (2015) · Proceedings of the National Academy of Sciences · doi:10.1073/pnas.1519666112 · Cited by 298
Self-citationNon-collinear generation of angularly isolated circularly polarized high harmonics
Hickstein, D. D., Dollar, F. J., Grychtol, P., Ellis, J. L., Knut, R., Hernández-García, C., Zusin, D., Gentry, C., Shaw, J. M., Fan, T., et al. (2015) · Nature Photonics · doi:10.1038/nphoton.2015.181 · Cited by 282
Self-citation
Metadata
- Authors
- Seaberg, M. D., Zhang, B., Gardner, D. F., Shanblatt, E. R., Murnane, M. M., Kapteyn, H. C., & Adams, D. E.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2014-07-22
- Volume
- 1
- Issue
- 1
- Pages
- 39
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2112146488
- Cited by
- 197
- References
- 18
- FWCI
- 17.76
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.