The DOI matches its Crossref record; 17 of the 17 references it cites were found in a registry or an index.
Megapixel time-gated SPAD image sensor for 2D and 3D imaging applications
Open accessAbstract
We present a 1 Mpixel single-photon avalanche diode camera featuring 3.8 ns time gating and 24 kfps frame rate, fabricated in 180 nm CMOS image sensor technology. We designed two pixels with a pitch of 9.4 µm in 7 T and 5.75 T configurations respectively, achieving a maximum fill factor of 13.4%. The maximum photon detection probability is 27%, median dark count rate is 2.0 cps, variation in gating length is 120 ps, position skew is 410 ps, and rise/fall time is < 550 p s , all FWHM at 3.3 V excess bias. The sensor was used to capture 2D/3D scenes over 2 m with resolution (least significant bit) of 5.4 mm and precision better than 7.8 mm (rms). We demonstrate extended dynamic range in dual exposure operation mode and show spatially overlapped multi-object detection in single-photon time-gated time-of-flight experiments.
Overview
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Run the check — free, no account needed. It reads the open-access text and checks the sources it cites.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Recovering three-dimensional shape around a corner using ultrafast time-of-flight imaging
Velten, A., Willwacher, T., Gupta, O., Veeraraghavan, A., Bawendi, M. G., & Raskar, R. (2012) · Nature Communications · doi:10.1038/ncomms1747 · Cited by 750
Single-photon avalanche diode imagers in biophotonics: review and outlook
Bruschini, C., Homulle, H., Antolovic, I. M., Burri, S., & Charbon, E. (2019) · Light: Science & Applications · doi:10.1038/s41377-019-0191-5 · Cited by 512
Self-citationConfocal non-line-of-sight imaging based on the light-cone transform
O’Toole, M., Lindell, D. B., & Wetzstein, G. (2018) · Nature · doi:10.1038/nature25489 · Cited by 505
2012 IEEE International Solid-State Circuits Conference
(2012) · doi:10.1109/isscc10053.2012 · Cited by 295
Kadambi, A., Whyte, R., Bhandari, A., Streeter, L., Barsi, C., Dorrington, A., & Raskar, R. (2013) · ACM Transactions on Graphics · doi:10.1145/2508363.2508428 · Cited by 227
A 512 × 512 SPAD Image Sensor With Integrated Gating for Widefield FLIM
Ulku, A. C., Bruschini, C., Antolovic, I. M., Kuo, Y., Ankri, R., Weiss, S., Michalet, X., & Charbon, E. (2019) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2867439 · Cited by 201
Self-citationArchitecture and applications of a high resolution gated SPAD image sensor
Burri, S., Maruyama, Y., Michalet, X., et al. (2014) · Optics Express · doi:10.1364/oe.22.017573 · Cited by 124
Bits From Photons: Oversampled Image Acquisition Using Binary Poisson Statistics
Yang, F. H., Lu, Y. M., Sbaiz, L., & Vetterli, M. (2011) · IEEE Transactions on Image Processing · doi:10.1109/tip.2011.2179306 · Cited by 121
A Modular, Direct Time-of-Flight Depth Sensor in 45/65-nm 3-D-Stacked CMOS Technology
Ximenes, A. R., Padmanabhan, P., Lee, M.-J., Yamashita, Y., Yaung, D.-N., & Edoardo Charbon, A. (2019) · IEEE Journal of Solid-State Circuits · doi:10.1109/jssc.2019.2938412 · Cited by 106
Computational time-of-flight diffuse optical tomography
Lyons, A., Tonolini, F., Boccolini, A., Repetti, A., Henderson, R., Wiaux, Y., & Faccio, D. (2019) · Nature Photonics · doi:10.1038/s41566-019-0439-x · Cited by 102
Cited by
A large-scale microelectromechanical-systems-based silicon photonics LiDAR
Zhang, X., Kwon, K., Henriksson, J., Luo, J., & Wu, M. C. (2022) · Nature · doi:10.1038/s41586-022-04415-8 · Cited by 438
Self-citationImaging and certifying high-dimensional entanglement with a single-photon avalanche diode camera
Ndagano, B., Defienne, H., Lyons, A., Starshynov, I., Villa, F., Tisa, S., & Faccio, D. (2020) · npj Quantum Information · doi:10.1038/s41534-020-00324-8 · Cited by 76
Advancements in fluorescence lifetime imaging microscopy Instrumentation: Towards high speed and 3D
Park, J., & Gao, L. (2024) · Current Opinion in Solid State and Materials Science · doi:10.1016/j.cossms.2024.101147 · Cited by 47
Shang, L., Bao, X., Peng, H., Chen, F., Wang, Y., Liu, K., Liang, P., Wang, Y., Tang, X., Masia, F., et al. (2025) · Light: Science & Applications · doi:10.1038/s41377-025-02020-8 · Cited by 4
Metadata
- Authors
- Morimoto, K., Ardelean, A., Wu, M.-L., Ulku, A. C., Antolovic, I. M., Bruschini, C., & Charbon, E.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2020-04-16
- Volume
- 7
- Issue
- 4
- Pages
- 346
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W3011749650
- Cited by
- 342
- References
- 17
- FWCI
- 34.39
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Megapixel time-gated SPAD image sensor for 2D and 3D imaging applications. https://app.cochat.ai/papers/10.1364/optica.386574
- The paper
- Morimoto, K., Ardelean, A., Wu, M.-L., Ulku, A. C., Antolovic, I. M., Bruschini, C., & Charbon, E. (2020). Megapixel time-gated SPAD image sensor for 2D and 3D imaging applications. Optica. https://doi.org/10.1364/optica.386574
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.