Deep phase decoder: self-calibrating phase microscopy with an untrained deep neural network
Open accessThe DOI matches its Crossref record; 26 of the 26 references it cites were found in a registry or an index.
Abstract
Deep neural networks have emerged as effective tools for computational imaging, including quantitative phase microscopy of transparent samples. To reconstruct phase from intensity, current approaches rely on supervised learning with training examples; consequently, their performance is sensitive to a match of training and imaging settings. Here we propose a new approach to phase microscopy by using an untrained deep neural network for measurement formation, encapsulating the image prior and the system physics. Our approach does not require any training data and simultaneously reconstructs the phase and pupil-plane aberrations by fitting the weights of the network to the captured images. To demonstrate experimentally, we reconstruct quantitative phase from through-focus intensity images without knowledge of the aberrations.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Phase retrieval algorithms: a comparison
Fienup, J. R. (1982) · Applied Optics · doi:10.1364/ao.21.002758 · Cited by 5,596 · cited 2×
“ased procedure. Once the weights are optimized, the sought phase image is retrieved as the output of the deep decoder part of the network. of the problem. The approach is fundamental to phase imaging [12] and has been practically employed in various systems. An immediate advantage is that our prior assumptions on the…”
BackgroundMethodLempitsky, V., Vedaldi, A., & Ulyanov, D. (2018) · 2018 IEEE/CVF Conference on Computer Vision and Pattern Recognition · doi:10.1109/cvpr.2018.00984 · Cited by 1,916
Wide-field, high-resolution Fourier ptychographic microscopy
Zheng, G., Horstmeyer, R., & Yang, C. (2013) · Nature Photonics · doi:10.1038/nphoton.2013.187 · Cited by 1,829
Marquet, P., Rappaz, B., Magistretti, P. J., Cuche, E., Emery, Y., Colomb, T., & Depeursinge, C. (2005) · Optics Letters · doi:10.1364/ol.30.000468 · Cited by 1,254 · cited 1×
“Quantitative phase microscopy (QPM) enables label-free imaging of transparent samples such as unstained cells and tissues [1,2], and non-absorbing microelements [3].”
BackgroundPhase recovery and holographic image reconstruction using deep learning in neural networks
Rivenson, Y., Zhang, Y., Günaydın, H., Teng, D., & Ozcan, A. (2017) · Light: Science & Applications · doi:10.1038/lsa.2017.141 · Cited by 1,059 · cited 1×
“For phase microscopy, trained DNNs give state-of-the-art performance in holographic [18], lensless [19], ptychographic [20], and through-scattering-media [21, 22] configurations, among others [23].”
BackgroundPhase Retrieval via Wirtinger Flow: Theory and Algorithms
Candès, E. J., Li, X., & Soltanolkotabi, M. (2015) · IEEE Transactions on Information Theory · doi:10.1109/tit.2015.2399924 · Cited by 1,049 · cited 2×
“To compare against our method, we reconstruct reference phase images with the accelerated Wirtinger flow algorithm [33] using (5) for 8 and 4 (defocus of 4, 8, 16, and 32 μm) measurements.”
MethodSpatial light interference microscopy (SLIM)
Wang, Z., Millet, L. J., Mir, M., Ding, H., Unarunotai, S., Rogers, J. A., Gillette, M. U., & Popescu, G. (2011) · Optics Express · doi:10.1364/oe.19.001016 · Cited by 751 · cited 1×
“Examples include through-focus [5,6], interferometric [7,8], and angle-scanning [9,10] microscopes.”
BackgroundLensless computational imaging through deep learning
Sinha, A., Lee, J., Li, S., & Barbastathis, G. (2017) · Optica · doi:10.1364/optica.4.001117 · Cited by 703
Multiplexed coded illumination for Fourier Ptychography with an LED array microscope
Tian, L., Li, X., Ramchandran, K., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.5.002376 · Cited by 584 · cited 1×
“of the objective and wavelength . Phase is recovered based on multiple images with some type of data diversity that translates phase information into intensity (e.g. defocus [5], illumination coding [31], pupil coding [32]). Here we adopt a pupil-coding scheme where the wavefront at the exit pupil [12] is dierently ab…”
MethodSelf-citationDeep speckle correlation: a deep learning approach toward scalable imaging through scattering media
Li, Y., Xue, Y., & Tian, L. (2018) · Optica · doi:10.1364/optica.5.001181 · Cited by 527 · cited 1×
“Although improved DNN architectures have been proposed [24–27], training-based approaches fundamentally rely on the reconstructed phase image to come from a distribution that is close to the one of the training images and are thus sensitive to misfits.”
BackgroundLearning to see through multimode fibers
Borhani, N., Kakkava, E., Moser, C., & Psaltis, D. (2018) · Optica · doi:10.1364/optica.5.000960 · Cited by 472 · cited 1×
“For phase microscopy, trained DNNs give state-of-the-art performance in holographic [18], lensless [19], ptychographic [20], and through-scattering-media [21, 22] configurations, among others [23].”
BackgroundEmbedded pupil function recovery for Fourier ptychographic microscopy
Ou, X., Zheng, G., & Yang, C. (2014) · Optics Express · doi:10.1364/oe.22.004960 · Cited by 443 · cited 1×
“ll for various phase microscopes and improve the reconstruction quality [8,14]. Another major advantage of the physics-based formulation is the possibility to incorporate algorithmic self-calibration [15,16]. It involves|in alternation with the phase retrieval step|minimizing the least-squares loss over unknown or par…”
BackgroundImaging through glass diffusers using densely connected convolutional networks
Li, S., Deng, M., Lee, J., Sinha, A., & Barbastathis, G. (2018) · Optica · doi:10.1364/optica.5.000803 · Cited by 435 · cited 1×
“For phase microscopy, trained DNNs give state-of-the-art performance in holographic [18], lensless [19], ptychographic [20], and through-scattering-media [21, 22] configurations, among others [23].”
BackgroundExperimental robustness of Fourier ptychography phase retrieval algorithms
Yeh, L.-H., Dong, J., Zhong, J., Tian, L., Chen, M., Tang, G., Soltanolkotabi, M., & Waller, L. (2015) · Optics Express · doi:10.1364/oe.23.033214 · Cited by 320 · cited 4×
“derings of phase as intensity from which quantitative phase is numerically recovered. For a given method, the performance and image quality is intrinsically governed by the phase reconstruction step. [11]. Traditionally, the phase reconstruction problem is addressed by solving an inverse problem by minimizing least-sq…”
BackgroundMethodInfluentialSelf-citationDeep learning approach for Fourier ptychography microscopy
Nguyen, T., Xue, Y., Li, Y., Tian, L., & Nehmetallah, G. (2018) · Optics Express · doi:10.1364/oe.26.026470 · Cited by 261 · cited 1×
“ties back to phase, have been used to obtain ecient phase retrieval algorithms. For phase microscopy, trained DNNs give state-of-the-art performance in holographic [18], lensless [19], ptychographic [20], and through-scattering-media [21,22] congurations, among others [23]. The results have validated the eciency of pr…”
MethodReliable deep-learning-based phase imaging with uncertainty quantification
Xue, Y., Cheng, S., Li, Y., & Tian, L. (2019) · Optica · doi:10.1364/optica.6.000618 · Cited by 198
Quantitative Phase Imaging and Artificial Intelligence: A Review
Jo, Y., Cho, H., Lee, S. Y., Choi, G., Kim, G., Min, H.-S., & Park, Y. (2019) · IEEE Journal of Selected Topics in Quantum Electronics · doi:10.1109/jstqe.2018.2859234 · Cited by 192
Deep Decoder: Concise Image Representations from Untrained Non-convolutional Networks
Heckel, R., & Hand, P. (2018) · arXiv (Cornell University) · doi:10.48550/arxiv.1810.03982 · Cited by 166 · cited 2×
“-generators, G p and G a, that synthesize a phase image and the pupil aberration of each individual measurement, respectively (see Fig. 1). For the phase generating network G p, we use a deep decoder [30], which transforms a randomly chosen and xed tensor B 0 2Rn 0 k consisting of kmany n 0-dimensional channels to an…”
BackgroundMethodSelf-citationPhysics-Based Learned Design: Optimized Coded-Illumination for Quantitative Phase Imaging
Kellman, M. R., Bostan, E., Repina, N. A., & Waller, L. (2019) · IEEE Transactions on Computational Imaging · doi:10.1109/tci.2019.2905434 · Cited by 158 · cited 1×
“Although improved DNN architectures have been proposed [24–27], training-based approaches fundamentally rely on the reconstructed phase image to come from a distribution that is close to the one of the training images and are thus sensitive to misfits.”
BackgroundSelf-citationDescloux, A. C., Grußmayer, K. S., Bostan, E., Lukeš, T., Bouwens, A., Sharipov, A., Geissbuehler, S., Mahul‐Mellier, A., Lashuel, H. A., Leutenegger, M., et al. (2018) · Nature Photonics · doi:10.1038/s41566-018-0109-4 · Cited by 147 · cited 1×
“Examples include through-focus [5,6], interferometric [7,8], and angle-scanning [9,10] microscopes.”
BackgroundSelf-citationRappaz, B., Breton, B., Shaffer, E., & Turcatti, G. (2014) · Combinatorial Chemistry & High Throughput Screening · doi:10.2174/13862073113166660062 · Cited by 109 · cited 1×
“QPM can use partially-coherent beams (in lieu of coherent ones [4]) to increase spatial resolution and light throughput with reduced speckle.”
MethodSingle-shot phase imaging with a coded aperture
Horisaki, R., Ogura, Y., Aino, M., et al. (2014) · Optics Letters · doi:10.1364/ol.39.006466 · Cited by 107 · cited 1×
“defocus [5], illumination coding [31], pupil coding [32]).”
BackgroundDenoising and Regularization via Exploiting the Structural Bias of Convolutional GeneratorsPreprint
Heckel, R., & Soltanolkotabi, M. (2019) · arXiv (Cornell University) · doi:10.48550/arxiv.1910.14634 · Cited by 86 · cited 1×
“, an autoencoder with more weights than the number of image pixels), and observed that early stopping the regularization yields good denoising performance, an effect theoretically explained in [29].”
BackgroundSelf-citationDenoising and Regularization via Exploiting the Structural Bias of Convolutional Generators
Heckel, R. (2020) · International Conference on Learning Representations · Cited by 39
Self-citationVariational Phase Imaging Using the Transport-of-Intensity Equation
Bostan, E., Froustey, E., Nilchian, M., Sage, D., & Unser, M. A. (2015) · IEEE Transactions on Image Processing · doi:10.1109/tip.2015.2509249 · Cited by 35 · cited 1×
“n example is to constrain the phase image to admit a sparse representation in the wavelet domain [13]. Such regularizers work well for various phase microscopes and improve the reconstruction quality [8,14]. Another major advantage of the physics-based formulation is the possibility to incorporate algorithmic self-cal…”
BackgroundSelf-citationPartially coherent phase imaging with simultaneous source recovery
Zhong, J., Tian, L., Dauwels, J., & Waller, L. (2014) · Biomedical Optics Express · doi:10.1364/boe.6.000257 · Cited by 31 · cited 1×
“ll for various phase microscopes and improve the reconstruction quality [8,14]. Another major advantage of the physics-based formulation is the possibility to incorporate algorithmic self-calibration [15,16]. It involves|in alternation with the phase retrieval step|minimizing the least-squares loss over unknown or par…”
BackgroundSelf-citation
Cited by
Far-field super-resolution ghost imaging with a deep neural network constraint
Wang, F., Wang, C., Chen, M., Gong, W., Zhang, Y., Han, S., & Situ, G. (2022) · Light: Science & Applications · doi:10.1038/s41377-021-00680-w · Cited by 400
Self-citation
Metadata
- Authors
- Bostan, E., Heckel, R., Chen, M., Kellman, M., & Waller, L.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2020-05-21
- Volume
- 7
- Issue
- 6
- Pages
- 559
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W3003088017
- Cited by
- 189
- References
- 26
- FWCI
- 10.88
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.