The DOI matches its Crossref record; 5 of the 5 references it cites were found in a registry or an index.
Molecular fingerprinting with bright, broadband infrared frequency combs
Open accessAbstract
Spectroscopy in the molecular fingerprint spectral region (6.7–20 µm) yields critical information on material structure for physical, chemical, and biological sciences. Despite decades of interest and effort, this portion of the electromagnetic spectrum remains challenging to cover with conventional laser technologies. In this paper, we present a simple and robust method for generating super-octave, optical frequency combs in the fingerprint region through intra-pulse difference frequency generation in an orientation-patterned gallium phosphide crystal. The attainable brightness from this tabletop source reaches the same level achievable by infrared synchrotron radiation with a bandwidth spanning from 4 to 12 µm. We demonstrate the utility of this unique coherent light source for high-precision, dual-frequency-comb spectroscopy of methanol and ethanol vapor. These results highlight the potential of laser frequency combs for a wide range of infrared molecular sensing applications from basic molecular spectroscopy to nanoscopic imaging.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
The HITRAN2012 molecular spectroscopic database
Rothman, L. S., Gordon, I. E., Babikov, Y., Barbe, A., Chris Benner, D., Bernath, P. F., Birk, M., Bizzocchi, L., Boudon, V., Brown, L. R., et al. (2013) · Journal of Quantitative Spectroscopy and Radiative Transfer · doi:10.1016/j.jqsrt.2013.07.002 · Cited by 3,255
Coddington, I., Newbury, N., & Swann, W. (2016) · Optica · doi:10.1364/optica.3.000414 · Cited by 1,754
Time-domain mid-infrared frequency-comb spectrometer
Keilmann, F., Gohle, C., & Holzwarth, R. (2004) · Optics Letters · doi:10.1364/ol.29.001542 · Cited by 734
Coherent Raman spectro-imaging with laser frequency combs
Ideguchi, T., Holzner, S., Bernhardt, B., Guelachvili, G., Picqué, N., & Hänsch, T. W. (2013) · Nature · doi:10.1038/nature12607 · Cited by 475
Generation and field-resolved detection of femtosecond electromagnetic pulses tunable up to 41 THz
Huber, R., Brodschelm, A., Tauser, F., & Leitenstorfer, A. (2000) · Applied Physics Letters · doi:10.1063/1.126625 · Cited by 413
Cited by
Field-resolved infrared spectroscopy of biological systems
Pupeza, I., Huber, M., Trubetskov, M., Schweinberger, W., Hussain, S. A., Hofer, C., Fritsch, K., Poetzlberger, M., Vamos, L., Fill, E., et al. (2020) · Nature · doi:10.1038/s41586-019-1850-7 · Cited by 304
Metadata
- Authors
- Timmers, H., Kowligy, A., Lind, A., Cruz, F. C., Nader, N., Silfies, M., Ycas, G., Allison, T. K., Schunemann, P. G., Papp, S. B., & Diddams, S. A.
- Venue
- Optica
- Publisher
- Optica Publishing Group
- Published
- 2018-06-04
- Volume
- 5
- Issue
- 6
- Pages
- 727
- ISSN
- 2334-2536 (ISSN-L)
- OpenAlex
- W2805389277
- Cited by
- 239
- References
- 5
- FWCI
- 15.19
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
How to cite
Cite CoChat for the checks on this page, and the paper for its own findings.
- This page
- CoChat. (2026). Citation check: Molecular fingerprinting with bright, broadband infrared frequency combs. https://app.cochat.ai/papers/10.1364/optica.5.000727
- The paper
- Timmers, H., Kowligy, A., Lind, A., Cruz, F. C., Nader, N., Silfies, M., Ycas, G., Allison, T. K., Schunemann, P. G., Papp, S. B., & Diddams, S. A. (2018). Molecular fingerprinting with bright, broadband infrared frequency combs. Optica. https://doi.org/10.1364/optica.5.000727
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.