Detection of hemoglobin in blood and urine glucose level samples using a graphene-coated SPR based biosensor
Open accessThe DOI matches its Crossref record; 1 of the 1 references it cites were found in a registry or an index.
Abstract
In this paper, we have presented a design and simulation of a graphene-coated surface plasmon resonance (SPR) based biosensor for targeting specific biological components. We have explicitly shown the detection of the hemoglobin level in blood samples and the glucose concentration level in urine samples by using the finite element method (FEM) based numerical simulation. In the blood component, the 0.001 refractive index increment causes a 6.1025 g/l hemoglobin (HB) level increment, which has been detected using this SPR based sensor with 200 deg/RIU angular sensitivity. Moreover, we have also detected the presence or absence of diabetes using the glucose concentration level in urine samples with this SPR sensor. Therefore, the novelty of this paper is detecting the blood hemoglobin level and glucose concentration levels in urine samples more accurately than the previously proposed whispering gallery mode (WGM) and photonic crystal nanocavity based optical sensors.
Overview
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Integrity signals
Registry
Cites
Statistics
Verification
Claims the paper makes
The claims and statistics of this paper haven’t been checked yet.
Free: it reads the open-access text and checks the first 5 claims that cite a source we can check. Create a free account to check every claim.
Self-check
Percentages, sums and reported differences re-computed from the paper’s own numbers.
The self-check needs the paper’s full text.
Citations
Cites
Measurement of tear glucose levels with amperometric glucose biosensor/capillary tube configuration
Yan, Q., Peng, B., Su, G., Cohan, B. E., Major, T. C., & Meyerhoff, M. E. (2011) · Analytical Chemistry · doi:10.1021/ac201700c · Cited by 185
Cited by
Pillai, S., Upadhyay, A., Sayson, D., Nguyen, B. H., & Tran, S. D. (2021) · Molecules · doi:10.3390/molecules27010165 · Cited by 95
Metadata
- Authors
- Mostufa, S., Paul, A. K., & Chakrabarti, K.
- Venue
- OSA Continuum
- Publisher
- Optica Publishing Group
- Published
- 2021-07-22
- Volume
- 4
- Issue
- 8
- Pages
- 2164
- ISSN
- 2578-7519 (ISSN-L)
- OpenAlex
- W3185130707
- Cited by
- 164
- References
- 1
- FWCI
- 6.51
- Type
- journal article
- Language
- en
- Open access
- gold
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review
Data sources
Bibliographic data: Semantic Scholar, OpenAlex, Crossref.
Contains information from the Semantic Scholar Academic Graph Datasets, made available under the ODC Attribution License (ODC-BY 1.0).
Semantic Scholar’s data is described in: Kinney, R., et al. (2023). The Semantic Scholar Open Data Platform. arXiv:2301.10140.