Monitoring of Vital Bio-Signs by Multimode Speckle Based Optical Fiber Sensor
Abstract
We present development and experimental validation of the multimode fiber sensor for monitoring of vital bio signs. The goal is to advance a simple, clothes embedded sensor to monitor the condition of the cardiovascular system.
Integrity signals
Registry
Cites
Statistics
Claims the paper makes
Claims other papers make about this one
Each is checked against this paper’s own text: does it say what the citing paper says it does?
A 400 μm multimode optical fiber without coating gave a very good combination of sensitivity and SNR.
“Benneth et al. [209] experimented with 400 µm multimode optical fiber (MOF) without coating and obtained a very good combination of sensitivity and SNR.”
From The Current State of Optical Sensors in Medical Wearables (2022) · cites this paper as [209]
Cites
Zalevsky, Z., Beiderman, Y., Margalit, I., et al. (2009) · Optics Express · doi:10.1364/oe.17.021566 · Cited by 231 · see citing works
Self-citationHistorical review of microbend fiber-optic sensors
Berthold, J. W. (1995) · Journal of Lightwave Technology · doi:10.1109/50.400697 · Cited by 190 · see citing works
Textile Fiber Optic Microbend Sensor Used for Heartbeat and Respiration Monitoring
Yang, X., Chen, Z., Elvin, C. S. M., Janice, L. H. Y., Ng, S. H., Teo, J. T., & Wu, R. (2014) · IEEE Sensors Journal · doi:10.1109/jsen.2014.2353640 · Cited by 142 · see citing works
Chen, Z., Lau, D., Teo, J. T., et al. (2014) · Journal of Biomedical Optics · doi:10.1117/1.jbo.19.5.057001 · Cited by 113 · see citing works
Flagged first, then by citations
Cited by
Sorted by citations
The Current State of Optical Sensors in Medical Wearables
Vavrinsky, E., Esfahani, N. E., Hausner, M., Kuzma, A., Rezo, V., Donoval, M., & Kosnacova, H. (2022) · Biosensors · doi:10.3390/bios12040217 · Cited by 103 · see citing works
- Authors
- Bennett, A., Beiderman, Y., Agdarov, S., Beiderman, Y., Hendel, R., Straussman, B., & Zalevsky, Z.
- Affiliations
- Bar-Ilan University (IL)
- Technion – Israel Institute of Technology (IL)
- Corresponding author
- Bennett, Aviya
- Beiderman, Yevgeny
- Agdarov, Sergey
- Beiderman, Yafim
- Hendel, Rotem
- Straussman, Barak
- Zalevsky, Zeev
- Venue
- Biophotonics Congress: Biomedical Optics 2020 (Translational, Microscopy, OCT, OTS, BRAIN)
- Publisher
- Optica Publishing Group
- Published
- 2020
- Pages
- TW4B.5
- OpenAlex
- W3028184937
- Cited by
- 1
- References
- 4
- Citations by year
- 2022: 1
- FWCI
- 0.45
- Type
- conference paper
- Language
- en
- Open access
- closed
- Locations
- Optics in the Life Sciences (publishedVersion)
- Topics
- Physical Sciences › Engineering › Biomedical Engineering › Non-Invasive Vital Sign Monitoring
- Physical Sciences › Engineering › Electrical and Electronic Engineering › Advanced Fiber Optic Sensors
- Health Sciences › Medicine › Radiology, Nuclear Medicine and Imaging › Optical Imaging and Spectroscopy Techniques
- Keywords
- speckle, fiber optic sensors, vital signs monitoring, cardiovascular monitoring, wearable sensors
About these checks
Registry, retraction, Cites and statistics results are computed, not judged, with one exception: a printed reference that no index lists is read once by a model before it counts as a citation error. Claims are extracted by a model and kept only when their quote appears verbatim in the text; each cited source is then checked, with a model’s help, for whether it says what the claim relies on. Those verdicts can be wrong — read the claim’s quote and the cited source before relying on one.
Statistics and arithmetic are recomputed, not judged.
Confidence bands are shown only for fields calibrated on our annotated test set. None is calibrated yet, so no band is shown.
What counts as a claim ›How we measure confidence ›How we check this ›
Are you an author, or do you see a problem with this page? Request a review